https://www.XPOtool.com
Item 51537–51541
Page 4
The Tool Experts
08 2022-1
Additional safety precautions
Have the following checked by an expert before using the pump (important for your own safety,
too):
•
Ground connection
•
Neutral conductor
•
Fault-current circuit breaker needs to comply with the safety regulations and needs to work
faultless.
•
The electrical connections need to be protected from humidity.
•
When a danger of flooding occurs, the electrical connections need to be placed in a high area.
•
The circulation of aggressive liquids as well as the circulation of abrasive substances is to be
avoided.
•
The motorised waste water pump needs to be protected from frost.
•
The pump needs to be protected from dry-running. The pump should be kept away from chil-
dren.
Resistance
•
The waste water pump is suited for a circulation of water with a maximal temperature of 35
℃
.
•
The pump might not be suited for other liquids, especially motor oils, cleaning detergents, and
other chemical products.
Assembly
The waste water pump is installed the following way:
•
in stationary position with a fixed pipeline or
•
in stationary position with a flexible pipe.
Please note!
•
The pump should never be installed hanging self-supporting of the pressure line or the electricity
cable. The waste water pump needs to be hung up by the designated handle or placed on the
floor of the shaft. To ensure the impeccable functioning of the pump, the shaft floor needs to be
kept free of mud and dirt of any kind.
•
When the water level has sunk too low, the mud in the shaft dries fast and stops the pump from
starting. It is necessary to regularly check the pump (by performing tests before operation).
•
The float switch is adjusted to allow the pump to start immediately.
Note!
The pump shaft should have a minimum size of 40×40×50
cm, so that the floater can move freely.
Power supply
The pump is equipped with a proper protective contact plug. The pump is meant to be connected to a
220/230
V~50
Hz safety socket. Ensure that the socket is sufficiently secured (at least 6
A) and is in an
excellent condition. Place the electricity plug into the socket and the pump is ready for use.
Important note!
If the main cable or the socket has been damaged due to external influences, repairs
on the cable are prohibited. Repair-work may only be carried out by a qualified technician.