05 2022-1

 

 

Disconnect  the  device  from the  power supply and let it cool down  before cleaning,  maintaining, and 
storing it. The liquid could be contaminated due to leaking lubricants.

 

 

Caution!

 

It is not possible to repair the electric parts of this pump. The power cord cannot be replaced. 

If the power cord or the plastic-encased and encapsulated motor piece is damaged, the entire device 
must be scrapped.

 

 

Warning!

 Electric shocks can be dangerous to life. Therefore, absolutely obey the following in-

structions:

 

 

 

The pump can only be operated on a properly earthed and insulated socket.

 

 

Caution!

 On standing water, garden ponds, swimming ponds and near them, the pump can only be 

used with a fault current circuit breaker with a rated current of up to 30

 

mA. Observe local regulations 

for connection to power supply, too. The pump must not be operated in swimming pools, paddling pools 
of  any  kind  or  other  water  bodies  with  people’s  or  animals’  being  present  during  operation.  It  is  not 
permitted to operate the pump while people or animals are in the danger zone.

 

 

 

Pumps equipped with a 10

 

m mains cable, min. H05RN-F, can only be operated outside of build-

ings.

 

 

Pull the power plug before any maintenance work.

 

 

Should the pump cable or the plug be damaged, the cable must not be repaired. In that case, 
the pump must not be operated any longer.

 

 

The pump can only be used for pumping water.

 

 

The pump must never be suspended from the pressure line or a live cable.

 

 

The pump must be protected from frost.

 

 

Children must not have access to the pump; take the appropriate preventive measures.

 

 

Using power cords, extension cords, connection cords or adaptors without safety contact is not 
permitted.

 

 
 

Main components and scope of delivery

 

 

Main components (Fig.

 

1)

 

 

 

Name

 

 

Name

 

1

 

Fountain pump

 

6

 

Fountain tube

 

2

 

Suction basket with BIOCELL insert

 

7

 

Stepped fountain

 

3

 

Transport handle

 

8

 

Bell-shaped fountain

 

4

 

Sleeve

 

9

 

Bubbles-forming fountain

 

5

 

Spout connection

 

 

 

 

Scope of delivery

 

 

 

Open the packaging to carefully take out the device.

 

 

Remove the packaging material as well as all packaging and transport locks (if present).

 

 

Check the delivery for completeness.

 

 

Check the device and its accessories for transport damages.

 

 

If possible, keep the packaging until the expiration of the warranty period.

 

 

Warning!

 

The device and  its packaging  material are  not children’s toys! Children must no play  with 

plastic bags, foils, and small parts! There is a risk of swallowing and suffocation!

 

 

 

Summary of Contents for 62547

Page 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...y avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbende...

Page 3: ...you for purchasing this quality product To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device Please read the operation instruc tions carefully and make sure you have understood its content Keep these operation instructions safe ...

Page 4: ...such a device is available in the installation we recommend using a PRCD S intermediate switch personal protection intermediate switch To do this contact a qualified electrician This device is not suitable for use in swimming pools paddling pools of any kind or other water bodies with people s or animals being present during operation The device must not be operated while people or animals are in ...

Page 5: ...le min H05RN F can only be operated outside of build ings Pull the power plug before any maintenance work Should the pump cable or the plug be damaged the cable must not be repaired In that case the pump must not be operated any longer The pump can only be used for pumping water The pump must never be suspended from the pressure line or a live cable The pump must be protected from frost Children m...

Page 6: ...it is the user not the manufacturer who is liable for any damage or injuries Technical specifications Voltage V 220 240 Frequency 50 Power absorption W 50 Max flow rate ℓ h 1750 Max head m 1 6 with stepped fountain 1 1 with bubbles forming fountain 0 32 Max immersion depth m 3 Max bell forming fountain diameter m 0 45 Protection type IPX8 waterproof Max water temperature 35 Before commissioning Ma...

Page 7: ...s slightly above the pool pond floor which prevents the device from being excessively contaminated from the bottom sludge Make sure that the inlets on the suction basket are not blocked Make sure that the pump is entirely covered with water Do not operate the pump if it is outside the water or if it protrudes above the water surface Operation The pump has 3 operation modes only as fountain stepped...

Page 8: ...ntrol and maintain the pump In case the head or flow rate drops the filter must be cleaned with lukewarm water In case of hard water regularly clean the rotating parts of the pump Before prolonged periods of non use and before winter storage the pump must thoroughly be rinsed with water and completely emptied Allow the pump to be stored in a dry place In case of risk of frost the pump must entirel...

Page 9: ...eck voltage The device does not pump Blocked inlet sieve Clean inlet sieve with water jet Bent pressure tube Unbend The flow rate is insufficient Blocked inlet sieve Clean inlet sieve with water jet Reduced performance by heav ily contaminated water and abra sive components in the water Clean device replace wearing parts Caution The pump must not run dry ...

Page 10: ...separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment a...

Reviews: