1. Place a full container of spraying material
underneath the suction tube
(a)
. Secure the
return tube
(b)
into a waste container.
2.
Turn the pressure control dial to maximum pres-
sure. Turn the
PRIME/SPRAY
knob to
PRIME
.
3. Plug in the sprayer and move the
ON/OFF
switch to the
ON
(l)
position.
The unit will begin to draw material up the
suction tube, into the pump, and out the
return tube. Let the unit cycle long enough
to remove test fluid from the pump, or until
spray material is coming from the return
tube.
4.
Switch the pump
OFF (O)
. Remove the re-
turn tube from the waste container and
place it in its operating position above the
container of spraying material.
8. Purging and Priming the Spray Hose
1. Unlock the spray gun and turn the
PRIME/SPRAY
knob to
PRIME
.
The spray tip SHOULD NOT
be attached to your spray gun
when purging your spray
hose.
2.
PULL
the trigger and aim the spray gun at the
side wall of a waste container.
If using oil-based
materials, the spray gun must be grounded
while purging (see warning below).
Keep hands clear from fluid stream. Ground the
gun by holding it against the edge of a metal
container while flushing. Failure to do so may
lead to a static electric discharge which may
cause a fire.
3. While pulling the trigger, switch the pump
ON (l)
,
AND
turn the
PRIME/SPRAY
knob to
SPRAY
.
Hold the trigger until all air, water, or solvent is purged from the spray hose and material is
flowing freely.
If the PRIME/SPRAY knob is still on
SPRAY,there will be high pressure in
the hose and spray gun until the
PRIME/SPRAY knob is turned to PRIME.