16. Cleanup - Cleaning the Suction Set
1. Lock the gun and turn the pump
OFF
(O)
.
2. Remove the suction hose and the return
tube and clean it using the appropriate clean-
ing solution. You should also wipe the threads
of the inlet nut (a) and remove and clean the
solution set inlet filter.
3. When the suction set is clean,
thread the suction tube back into the
inlet valve, and replace the return tube
onto the return tube fitting. Replace
clip.
4. Submerge the suction set into a bucket
of
NEW
cleaning solution.
5. Turn the
PRIME/SPRAY
knob to
PRIME
. Turn the pump
ON (l)
, and
trigger the gun once into a waste con-
tainer to relieve pressure.
6. Let the pump circulate cleaning solu-
tion through the suction set for 2-3
minutes. Turn the pump
OFF
.
Note!
In case yo
u used oil-based material,
you must flush the pump again with water in
order to prepare it for storage.
Move on to 17. Cleaning the Spray Gun Com-
ponents
https://www.XPOtool.com
Artikel 63003
Seite 18
The Tool Experts
04 2021