Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of  injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Safety instructions

 

 

 Caution!

 

 

The use  of this device  is only allowed with a fault current protection switch with  a triggering 
nominal current up to 30

 

mA (according to VDE 0100

 

Article 702 and 738).

 

 

The device is not intended for use by persons (including children) with impaired or limited phys-
ical, sensory, and mental abilities or lack of experience and/or real knowledge, unless they are 
supervised by a person responsible for their safety or follow the instructions made by this person 
on how to correctly use the device.

 

 

Children should be supervised to ensure that they do not play with the device.

 

 

 Attention!

 

 

The compressor head can become very hot. 

Burning hazard!

 

 

Perform a visual inspection of the device before every use. Do not use the device if the safety 
appliances are damaged or worn out. Never override safety regulations.

 

 

Only use the device accordingly to the intended purpose stated in this manual.

 

 

You are responsible for the safety of the working zone.

 

 

If the cable or the plug is damaged due to external influences, the cable must not be repaired, 
but must be replaced with a new one. This work can only be carried out by an electrician.

 

 

The  voltage  of  230

 

V  AC  indicated  on  the  nameplate  of  the  device  must  match  the  existent 

mains voltage.

 

 

Never lift, transport, or suspend the device by its power cord.

 

 

Make sure that the electrical plug connection is protected from flood and moisture.

 

 

Before any maintenance work or adjustment, pull out the plug.

 

 

The user is responsible for complying with local safety and mounting regulations. Ask an elec-
trician if you have questions.

 

 

In case of device failure, repairs can only be carried out by an electrician.

 

 

 Notes!

 

 

Choose  the  right  compressor  with  the  appropriate  air  volume  and  air  pressure  to  match  the 
actual work requirements.

 

 

Never expose the device to dust, acid, steam, explosive or flammable gases, or weather influ-
ences (rain, sun, fog, snow).

 

 

The vacuum pump can only be operated in an appropriate environment (good ventilation, am-
bient tempe5

 

–+40

 

).

 

 

Never use the compressor barefoot or with wet hands or feet.

 

 

Never allow children to touch the switched-on compressor or to insert the plug. It may cause 
burns or electric shocks.

 

 

Do not open or damage any part of the compressor. If necessary, contact a qualified person.

 

 

By opening the drain valve, the water can be evacuated. Always release the water before not 
using the compressor for a long time. Store the compressor in a well-ventilated place.

 

 

Always wear protective goggles. Under no circumstances should you direct the airflow towards 
your body or other persons’ bodies or animals.

 

 

Never use the compressor in areas with vapours or humidity or near bodies of water.

 

 

Switch off the compressor if you do not use it. Disconnect from mains before you repair, recon-
dition, maintain, clean, or replace parts. Never use the power cable as handle. Keep the cable 

Summary of Contents for AS196A

Page 1: ...r may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...f you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Ger...

Page 3: ... electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never lift transport or suspend the device by its power cord Make sure that the electrical plug connection is protected from flood and moisture Before any maintenance work or adjustment pull out the plug The user is responsible for complying with local safety and mounting regulations...

Page 4: ...y qualified persons and using original spare parts Properties Air tank emits regular pulsation free air flow Oil free piston compressor no polluted air With water filter pression adjustment and manometer Double air pressure switch Switch 1 Low pressure autostop switch for airbrush jobs Switch 2 High pressure non autostop switch for other high air pressure tools Automatic start without counterpress...

Page 5: ...a leakage It is of great importance to seal any leak as soon as possible to avoid any impact on the capacity and efficiency of the compressor A leakage leads to the auto stop and auto start constantly being switched on and off Difference between maximum pressure and operating pressure The maximum pressure is the highest possible pressure that a compressor can generate The maximum pressure is the p...

Page 6: ...2 Pull up the adjusting knob a clockwise rotation increases the pressure a counter clockwise rotation reduces the pressure 3 Rotate the adjusting knob to achieve the right working pressure and engage it by pushing it downwards 4 Do not rotate the knob against high resistance If necessary the height and position of the knob can vary slightly 5 For emptying the condensed water collector use the wate...

Page 7: ... the user Reinstall cylinder valve and place it in the right direction Engine runs but makes noises Bearings are loose or damaged Replace bearings Screws in connecting rod loose Tighten or replace screws Airbrush gun does not function properly insufficient blowing pressure Air connection not tight Seal air connection with insulat ing tape Air hose torn off Re mount the air hose Screws of cylinder ...

Page 8: ... Adaptor 4 Rear main unit 22 Front cover 41 Pressure controller 5 Screw 23 Filter 42 Container 6 Stationary motor 24 O ring 43 Three way manifold 7 Bearing 25 Cylinder block 44 Three way manifold 8 Rotary motor 26 O ring 45 Check valve 9 Front main unit 27 Cylinder head 46 Hose nut 10 Counterweight 29 Filter valve 47 Plug 11 Pressure gauge 30 Handle 48 Sleeve 12 Bearing 31 Pressure switch 49 Safet...

Page 9: ...2022 1 13 Retainer ring 32 Water release needle 50 Drain valve 14 Compression ring 33 Capacitor 51 Adaptor 15 Hose 34 On off switch 52 Hose 16 Solenoid valve 35 Wire 53 Screw nut 17 Cylinder 36 Rubber pad 54 Base plate 18 Valve plate 37 Hexagon head nut 55 Cover ...

Page 10: ...ion and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environment ...