background image

English - 17

FILTER MODEL 

NUMBER

Type of Filter

Size

Thickness

Function

NFS16

Nylon Mesh Filter

16 x 16 in.

-

Primary filtration for 

visible and coarse 

particles.

RP20

Rigid Polyester 

Filter

20 x 20 in.

1 in.

RP24

24 x 24 in.

1 in.

PF16

Pleated Media 

Filter

16 x 16 in.

0.8 in.

Medium filtration for fine 

dust.

PF19

19 x 19 in.

1.4 in.

PF23

23 x 23 in.

1.8 in.

CF35

Carbon Filter

16 x 16 in.

1.4 in.

Filtration for gases.

CF35-490

19 x 19 in.

14 in.

CF35-595

23 x 23 in.

14 in.

HEPA300-

406PV

Plastic V-Shaped 

HEPA Filter

16 x 16 in.

11.5 in.

Final filtration for micro 

particles.

HEPA300-

490PV

19 x 19 in.

11.5 in.

HEPA300-PV

23 x 23 in.

11.5 in.

Filter Specification

Summary of Contents for AP-1500D Series

Page 1: ...r Scrubber Owner s Manual Model AP 1500D Series AP 1800D Series AP 2500D Series 115V 60Hz Read and save these instructions Index NA 1 A40 Edition 1 3 Final www xpower com 1 855 855 8868 info xpower co...

Page 2: ...speed control device DO NOT touch this appliance or the plug with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline p...

Page 3: ...English 3 1 2 7 8 9 10 11 12 13 16 17 18 19 20 21 22 6 23 24 25 26 29 30 31 32 33 34 35 4 5 3 27 28 14 15 Parts Description Machine...

Page 4: ...9 Handle Cover 20 Handle Tube 21 Housing 22 Air Quality Sensor Cover 23 Air Quality Sensor 24 Power Switch 25 Speed Switch Knob 26 Control Panel 27 Speed Switch Circuit Board 28 Circuit Breaker 29 Air...

Page 5: ...OWER s unique and highly innovative Air Scrubbers create a fresh and clean environment for various purposes With a special designed powerful motor XPOWER Air Scrubbers are able to provide suction in e...

Page 6: ...the filter before the first useage The accuracy of the pressure gauge might be affected by transportation Before the first usage you should zero the pressure gauge in order to ensure the accuracy of t...

Page 7: ...ff the hex screw with a hex screw driver on the inlet grill cover 2 Take out the inlet grill cover 3 Put the screws through the holes on handle and the back of the machine housing 4 Fasten the screws...

Page 8: ...relative humidity level High humidity level could cause blockage and damage to filters Power Cord The power cord has a length of 25 feet 7 6 meters Select a location where the power cord can reach the...

Page 9: ...tes Environmental Protection Agency EPA the index light corresponds to different levels of health concern as below Control Panel Circuit Breaker Air Quality Monitor Power Switch Speed Switch Air Quali...

Page 10: ...tration efficiency as well as the airflow have diminished You should check clean or replace the filters See Page 12 Filter Maintenance Even if the pressure gauge shows negative pressure is still lower...

Page 11: ...e wheels Push forward to transport with the trolley handle User Maintenance Instructions Frequent maintenance is recommended on this appliance Failure to follow the maintenance instructions may cause...

Page 12: ...ren Use a damp cloth to wipe the surface of the housing Do not clean the unit with water directly Check if the grille covers are clean Remove dirt or any other objects that could block the air inlet a...

Page 13: ...ptured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby environment You must replace the filter if all the other filters are clean and however th...

Page 14: ...l regulations Tips On one of the side of each filter there is a label with an arrow showing the airflow direction When placing the filter the side with label should face up The arrow on the label shou...

Page 15: ...the additional electrical receptacle and press circuit reset button Unit runs but no or very low air movement Air outlet is blocked Remove blockage Filters are fully loaded The filter clean change lig...

Page 16: ...0 A Rated Airflow 700 CFM 1100 CFM 1800 CFM Speed Control Variable Speeds Cord Length 13 ft 4 0 m 25 ft 7 6 m Unit Dimension L x W x H 49 3 x 55 5 x 91 in 19 4 x 21 9 x 35 8 cm 57 4 x 63 9 x 94 6 in 2...

Page 17: ...in PF16 Pleated Media Filter 16 x 16 in 0 8 in Medium filtration for fine dust PF19 19 x 19 in 1 4 in PF23 23 x 23 in 1 8 in CF35 Carbon Filter 16 x 16 in 1 4 in Filtration for gases CF35 490 19 x 19...

Page 18: ...ordant with product instructions stated in Owner s Manual 3 4 Failure to follow the product instructions or lack of necessary maintenance stated in Owner s Manual Before contacting XPOWER please try o...

Page 19: ...the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and...

Page 20: ...Read and save these instructions Index NA 1 A40 Edition 1 3 Final www xpower com 1 855 855 8868 info xpower com 668 S 6th Ave City of Industry CA 91746 USA XPOWER Manufacture INC...

Reviews: