background image

English - 6

Air Quality Monitor

• When this monitor blinks, it indicates the Air Quality Sensor is now preparing for 

detection.

• The digital display will show the concentration of fine particulate matter (PM

2.5

) in the 

environment in μg/m

3

.

• The index light will indicate the air quality category of the environment. According to the  

Air Quality Index developed by the United States Environmental Protection Agency (EPA), 

the index light corresponds to different levels of health concern as below:

Control Panel

Circuit Breaker

Air Quality Monitor

Power Switch

Speed Switch

Air Quality Sensor

Pressure Gauge

RE

SE

T  

      

      PRES

S    

     T

O

   

   

   

   

   

10

0  

     

      

200   

           300     

        

40

0   

     

     

50

0

OFF

MAX

MIN

Air Quality

Good Moderate Poor

Circuit Breaker

Air Quality Monitor

Power Switch

Speed Switch

Air Quality Sensor

Pressure Gauge

RE

SE

T  

      

      PRES

S    

     T

O

   

   

   

   

   

10

0  

     

      

200   

           300     

        

40

0   

     

     

50

0

OFF

MAX

MIN

Air Quality

Good Moderate Poor

Circuit Breaker

Air Quality Monitor

Power Switch

Speed Switch

Air Quality Sensor

Pressure Gauge

RE

SE

T  

      

      PRES

S    

     T

O

   

   

   

   

   

10

0  

     

      

200   

           300     

        

40

0   

     

     

50

0

OFF

MAX

MIN

Air Quality

Good Moderate Poor

Circuit Breaker

If the machine stops working, pressing the 

RESET BUTTON 

to reset the machine.

Power Switch

• Turn to “

O

” position to switch the Air Scrubber OFF. Turn to “

I

” position to switch the Air 

Scrubber ON.

Index Light

Levels of Health Concern according to the AQI by EPA

Green / Good

Good

Orange (Yellow) / 

Moderate

Moderate or, Unhealthy for Sensitive Groups

Red / Poor

Unhealthy, or Very Unhealthy, or Hazardous

Summary of Contents for AP-2500D

Page 1: ...Air Scrubber Owner s Manual Model AP 2500D 115V 60HZ Read and save these instructions Index NA 1 A40 Edition 1 1 Final www xpower com 1 855 855 8868 info xpower com...

Page 2: ...speed control device DO NOT touch this appliance or the plug with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline p...

Page 3: ...English 3 1 2 3 4 5 6 7 8 9 10 11 12 15 16 17 18 19 20 21 22 23 24 25 28 29 30 31 32 33 34 35 36 37 26 27 13 14 Parts Description...

Page 4: ...6 Motor Housing Fixator Assembly 7 Motor Fixator 8 Motor Right Housing 9 Heat Insulation Plate 10 Motor 11 Bushing 12 Fan 13 Motor Left Housing 14 Motor Control Circuit Board Assembly 15 Rivet Nut 16...

Page 5: ...r optimal efficiency and higher filter lifespan the Air Scrubber should not be operated in an environment with a high relative humidity level High humidity level could cause blockage and damage to fil...

Page 6: ...200 300 4 0 0 5 0 0 OFF MAX MIN Air Quality Good Moderate Poor Circuit Breaker Air Quality Monitor Power Switch Speed Switch Air Quality Sensor Pressure Gauge R E S E T PR E S S T O 0 1 0 0 200 300 4...

Page 7: ...osition between MAX and MIN to switch the Ventilateur Axial ON You can adjust to any desired speed variably MAX is the highest speed and MIN is the lowest speed Preesure Gauge This measures the negati...

Page 8: ...e unplug and uninstall power cords and all the extensions Store the appliance in a dry and cool indoor place Make sure it s out of reach of children Use a damp cloth to wipe the surface of the housing...

Page 9: ...concentrated particles are captured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby environment You must replace the filter if all the other fi...

Page 10: ...masks eye protectors gloves and coveralls You should place the used filters in a sealed plastic bag before disposing Follow local disposal regulations Tips On one of the side of each filter there is...

Page 11: ...nd reconnect the power cord The circuit breaker on the additional electrical receptacle Daisy chain trips Remove all appliances on the additional electrical receptacle and press circuit reset button U...

Page 12: ...7 x 38 8 in 74 8 x 67 8 x 98 6 cm Unit Weight 98 66 lbs 44 75 kg Machine Specification FILTER MODEL NUMBER Type of Filter Size Thickness Function RP 24 Rigid Polyester Filter 24 x 24 in 1 in Primary f...

Page 13: ...ordant with product instructions stated in Owner s Manual 3 4 Failure to follow the product instructions or lack of necessary maintenance stated in Owner s Manual Before contacting XPOWER please try o...

Page 14: ...the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and...

Page 15: ...English 15...

Page 16: ...Read and save these instructions Index NA 1 A40 Edition 1 1 Final www xpower com 1 855 855 8868 info xpower com 668 S 6th Ave City of Industry CA 91746 USA XPOWER Manufacture INC...

Reviews: