background image

- 5 -

- 4 -

Operation Instructions

Safety Instructions

XPOWER High Static Blowers are intended to fill up inflatables, advertising displays, structures, 

etc. Durable and easy to operate with an effective balance of static pressure and airflow, the 

units are suitable for a variety of applications.

1. XPOWER High Static Blowers are shipped ready-to-use. Prior to plugging the unit into the

power source, inspect completely for any shipping damage.

2. With the unit unplugged, carefully place the unit on stable, flat, and dry surface.

3. Snugly attach your inflatable tube around the exhaust opening by using the velcro strap or

any other form of tightener.

4. Plug the cord into a grounded GFCI outlet only. Using a 3-prong to 2-prong adapter is strictly

prohibited.

5. Turn on the switch (except BR-6) to make sure the blower is operating correctly and the

inflatable functions properly. BR-6 will work automatically when connected to power source.

6. All blowers in operation must be supervised at all times.

1. Never place the XPOWER High Static Blowers in close proximity to any heat source or open flame. The 

inflatable is flammable and could cause a fire and serious injury if not handled properly.

2. Do not operate the unit close to any dangerous areas such as explosive gases, flammables, heaters

and unventilated environments that may result in explosions or electrical hazards.

3. Do not operate the blower without the inflatable attached because the blower must have back

pressure in order to avoid any damage to the motor.

4. Keep children away from the unit at all times while in operation or plugged in. This product is not a toy 

and should only be used for its intended purpose.

5. Do not put fingers or other objects in any part of the unit while it is in operation or plugged in.

6. To prevent electric shock, do not drop unit into water, never plug in or unplug the appliance with wet 

hands or while standing in water.

7. Avoid sands, small rocks and other small objects being sucked in the blower.

8. To avoid risk of injury, do not direct stream of air at face or body.

9. If the power cord is damaged, it must be replaced by the XPOWER Manufacture, Inc. or an XPOWER

authorized service agent or a qualified electrician in order to avoid a hazard.

10. Do not operate in pooled or accumulated water to avoid electric shock.

(Continued at Page 6)

Summary of Contents for BR-6

Page 1: ...SAVE THESE INSTRUCTIONS OWNER S MANUAL HIGH STATIC BLOWER MODEL BR 6 BR 15 BR 25 BR 35 BR 252A 115V 60HZ XPOWER MANUFACTURE INC 240 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 www xpower com ...

Page 2: ...Inc is bringing a series of products with the most advanced technology in today s market Your new XPOWER blower is engineered with top quality motors and superb housing to provide strong and lasting performance All our products have a fully integrated design with state of the art miniaturization allowing them to be light weight quiet and rugged without sacrificing power or durability Trust in XPOWE...

Page 3: ...imes 1 NeverplacetheXPOWERHighStaticBlowersincloseproximitytoanyheatsourceoropenflame The inflatableisflammableandcouldcauseafireandseriousinjuryifnothandledproperly 2 Do not operate the unit close to any dangerous areas such as explosive gases flammables heaters andunventilatedenvironmentsthatmayresultinexplosionsorelectricalhazards 3 Do not operate the blower without the inflatable attached beca...

Page 4: ...inoperationmustbesupervisedatalltimes 22 Anymisuseorabuseofthisproductwillvoidyourwarranty GROUNDING PIN Grounding methods METAL SCREW OUTLET BOX COVER OF GROUNDED A GroundingInstructions This product must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by proving an escape wire for electric current This product is equipped with a cord having a ...

Page 5: ...l Dual Dual Dual Housing PP PP PP PP PP Safety C fica on ETL C ETL ETL C ETL ETL C ETL ETL C ETL ETL C ETL Maintenance Ins Tr PROBLEM POSSIBLE CAUSE SOLUTION Motor not running Unit is not plugged in or switch is in OFF mode Make sure the unit is plugged in and switch is in ON mode Def ve power outlet Check outlet or use another outlet Faulty switch cord Replace switch or cord Scraping noise from bl...

Page 6: ... cover Front cover Power cord Capacitor Impeller Shaft bushing Switch 1 2 3 4 5 Wiring case 6 7 8 9 10 Sealing pad 11 Motor Motor cover Bottom cover Front cover Power cord Capacitor Impeller BR 15 25 35 252A Parts List Sealing ring Base board Parts may vary from different models Contact XPOWER for more information ...

Page 7: ...mp Axial Fans Air Scrubbers Dehumidifiers Misting Fans Inflatable Advertising Equipment High Static Blowers Centrifugal Blowers Vertical Advertisement Blowers Air Pumps Professional Retail Pet Grooming Equipment Professional Pet Grooming Dryers DIY Pet Grooming Dryers Air Care Equipment More XPOWER Products Available Learn more at www xpower com or call 1 855 855 8868 ...

Page 8: ... in compliance with the instructions and specificationsforitsuse ForWarrantyserviceandpartsreplacement UScustomeronly youmust A Call1 855 855 8868foraRMA Return Merchandise Authorization number B Haveoriginalproofofpurchaseprovided C Usetheoriginalundamagedpackagingoranindustrialcertifiedpackagingmethod End user will be responsible for shipping the unit with RMA Number showing on the shipping label ...

Page 9: ...TO XPOWER MANUFACTURE INC 240 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 From ...

Reviews: