background image

- 12 -

Always wear a respirator and personal protective gear when removing or replacing filters. Lay 

the Air Scrubber flat, unlock top latch of the housing, open the inlet panel and remove filters.

- 14 -

CF35

 - Activated Carbon Filters are used to remove contaminants and impurities through the process 

of chemical absorption. The CF35 captures a wide variety of volatile organic compounds that includes 

smoke, food odors, fumes from paint and paint thinners, sewer odors and more. Carbon Filters can be 

reused if the adsorbed substances are removed. This process is known as 'regeneration'. Simply 

heating the spent carbon at a given temperature for an adequate length of time can regenerate activated 

carbon to the point where it can be reused. The CF35 fits the X-3500 model; it is placed inside the 

housing in front of the HEPA filter. Always make sure that the Air Scrubber is turned off when removing 

the carbon filter. Never use water to clean the CF35 filters. Use vacuum or clean cloth and lay it flat on 

a clean and dry surface. For best results, put the CF35 under the sun and leave it there for a couple of 

hours. The capacity of the carbon filter will vary widely depending on conditions, but it should be replaced 

when a decline of effectiveness is noted.

Precautionary Measure When Cleaning and Changing Filters

An air scrubber captures particles that can be hazardous to human health. 

During the process of changing filters, decontamination, or performing 

maintenance, large concentrations of captured particles can become 

airborne in the immediate area. For these reasons, air scrubber operators 

should wear appropriate personal protection equipment (PPE) when 

performing any type of service on an air scrubber. A NIOSH-approved 

respirator is always essential for these tasks. If you’ve used the air scrubber 

for mold remediation or in another environment with known contaminants, 

you should also consider wearing gloves, eye protection and coverall

NIOSH-Approved 

Respirator Mask

The particles captured by a filter can cause adverse human health effects once they are released into 

the air. For this reason, you should dispose of used filters with care. You should place used filters in a 

plastic bag and seal the top before disposing. Always follow local regulations before disposing. 

Disposal of Filters

The filters may need to be changed after certain period of time depending on your usage and the life of 

each type of filters

All filter accessories are available for purchase directly from XPOWER's headquarters in California.

Please call our Customer Service at (626) 376-0190 or email us at info@xpower.ws.

X-3500 Primary Filter Care

Filter Replacement

Summary of Contents for X-3300

Page 1: ...Models X 3300 X 3500 AIR SCRUBBER OWNER S MANUAL...

Page 2: ...ons 5 Parts List 6 7 4 Stage Filtration Systems 8 Maintenance 9 14 Cleaning of Washable Nylon Pre Filters 10 X 3300 Primary Filter Care 11 X 3500 Primary Filter Care 12 13 Filter Replacement 14 Troubl...

Page 3: ...h capacity motor for spaces up to 1500 sq ft Enjoy breathing healthier with your XPOWER Professional Air Purification Equipment Features 4 stage air filtration system Low amp usage with high airflow c...

Page 4: ...ility for examination and or repair 5 Air Scrubber is an automatically operated device To reduce the risk of injury disconnect from power supply before servicing 6 Do not run cord under carpet Do not...

Page 5: ...fully place the Air Scrubber upright on a stable flat dry surface 3 Plug the electrical cord into the power outlet 4 The unit can be used in 2 different angle positions vertical and horizontal 5 Turn...

Page 6: ...Filter Activated Carbon Filter Washable PETPurifying Filter Washable PETPurifying Filter WF35 16 x 16 x 1 4 HEPA35 16 x 16 x 1 4 HEPA Filter FILTER CLEAN CHANGE LIGHT STACKABLE SAFETY CERTIFICATIONS E...

Page 7: ...let 3 Inlet Panel 4 Latch 5 16 x16 Nylon Mesh Filter 6 Activated Carbon Filter 7 1 4 Thick HEPA Filter 8 9 Front Housing 10 Pressure Switch 11 Fan 12 Motor 13 HEPA Filter Change Light 14 Speed Control...

Page 8: ...5 6 1011 12 13 9 14 15 16 17...

Page 9: ...16 Washable Inner Nylon Mesh Filter CF35 16 x 16 x 1 4 Activated Carbon Filter HEPA35 16 x 16 x 1 4 HEPA Filter 4 Stage Filtration Systems 1st Stage 2nd Stage 4th Stage 3rd Stage X 3300 X 3500 WF35 Do...

Page 10: ...crubber and extend the life of primary filters Both the XPOWER X 3300 and X 3500 filtration system include easy to clean washable nylon pre filters that should be frequently maintained Monitor filters...

Page 11: ...uter nylon mesh filters then rinse with water and lay flat on a clean and dry surface to dry completely before re installing The NFR12 and NFS16 filters are used for X 3300 and X 3500 air scubbers as...

Page 12: ...t up when filters need attention Always make sure that the Air Scrubber is turned off before removing filters Cleaning X 3300 PET Purifying Filters WF35 1 Remove filters and lay them on a flat clean s...

Page 13: ...r an adequate length of time can regenerate activated carbon to the point where it can be reused The CF35 fits the X 3500 model it is placed inside the housing in front of the HEPA filter Always make...

Page 14: ...on respiratory problems The HEPA filter requires a simple maintenance routine which can be performed in a timely and cost effective manner To maximize HEPA filter life be sure to clean change the pre...

Page 15: ...ys essential for these tasks If you ve used the air scrubber for mold remediation or in another environment with known contaminants you should also consider wearing gloves eye protection and coverall...

Page 16: ...et Wiring failure Contact XPOWER for service repair Scraping noise from fan Obstruction at the intake or exhaust of fan Remove obstruction Fan broken Contact XPOWER for service repair Weak air flow Ob...

Page 17: ...tenance or repair or failure to perform necessary maintenance or repair or if the use of this product is not in compliance with the instructions and speci cations for its use For Warranty service and...

Page 18: ...ryers X 430TF w 430MDK 1 3 HP 3 8 Amps 2000 CFM X 800TF w 800MDK 3 4 HP 7 5 Amps 3200 CFM B 4 3 HP 10 Amps 150 CFM with vacuuming feature B 8 4 HP 12 Amps 150 CFM brushless DC motor with heater B 25 4...

Page 19: ...XPOWER MANUFACTURE INC Address 220 Clary Ave San Gabriel CA 91776 Tel 626 285 3301 Fax 626 285 3302 Warranty Registration Company Name Contact Person Title State Province Zip Country for US customer...

Page 20: ......

Page 21: ...es up to 1500 sq ft Enjoy breathing healthier with your XPOWER Professional Air Purification Equipment Models X 3300 X 3500 Features 4 stage air filtration system Low amp usage with high airflow capac...

Page 22: ...g 6 Do not run cord under carpet Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will no...

Page 23: ...ed speed and make sure the unit operates normally 6 To reduce the risk of injury close supervision is necessary when the machine is used near children Do not allow children to play with or around the...

Page 24: ...d Carbon Filter Washable PETPurifying Filter Washable PETPurifying Filter WF35 16 x 16 x 1 4 HEPA35 16 x 16 x 1 4 HEPA Filter FILTER CLEAN CHANGE LIGHT STACKABLE SAFETY CERTIFICATIONS ETL CETL 4 STAGE...

Page 25: ...ve all debris from both the inner and outer nylon mesh filters then rinse with water and lay flat on a clean and dry surface to dry completely before re installing The NFR12 and NFS16 filters are used...

Page 26: ...tration efficiency XPOWER Air Scrubbers include on board pressure sensors that automatically alert the Filter Change Clean Light when the filters need cleaning The filter may needs to be changed after...

Page 27: ...of effectiveness is noted Precautionary Measure When Cleaning and Changing Filters An air scrubber captures particles that can be hazardous to human health During the process of changing filters decon...

Page 28: ...sociated with indoor air pollution the filter is designed and implemented to trap even the tiniest contaminants approximately 99 97 of all particles measuring 0 3 microns that aren t usually captured...

Page 29: ...directly or indirectly to misuse abuse disassembly alteration corrosive chemicals improper voltage re ood negligence accident improperly or incorrectly performed maintenance or repair or failure to p...

Page 30: ...ryers X 430TF w 430MDK 1 3 HP 3 8 Amps 2000 CFM X 800TF w 800MDK 3 4 HP 7 5 Amps 3200 CFM B 4 3 HP 10 Amps 150 CFM with vacuuming feature B 8 4 HP 12 Amps 150 CFM brushless DC motor with heater B 25 4...

Reviews: