background image

www.xprgroup.com

1

EN

WS4-4D

4 Door access control unit with web access

DESCRIPTION

SPECIFICATIONS

FACTORY RESET

CHANGE PASSWORD

SOFTWARE SETTINGS

METHOD 1

ADDING READERS

METHOD 2 

ADDING USERS

ADDING SLAVE CONTROLLERS

FIRST CONNECTION AND CONFIGURATION

If you can not connect, it is because your network does not recognize the name of the

WS4-4D controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/

and download the tool called “Device Finder”.

The “Device Finder” will enable you to find out the IP address of the WS4-4D controller.

Run the “Device Finder” and you will get a list of all the WS4 controllers connected in

your network, including their IP addresses, just like the picture below.

To add 

2 readers on 1 Door

, select the reader (fig.2) and there, for “Type of Access”

select “Access with 2 readers” (fig 5). Fill the form for both readers and they will

merge in one door (fig. 6)

WS4-4D system can manage up to 10 WS4-4D boards in the same installation (with up to 20

doors, whether single or double). One WS4-4D must be master, the others must be

slaves. The 

master/slave

 selection is made with 

Dip-switch 2

: OFF - Master (factory

setting), ON - Slave.

Go to “Doors” and click on the link “Add slave”(fig.1). Enter the serial number of the

WS4-4D to be added and click Search. If it finds it, the system directly adds this slave

into the installation and you can configure its doors (fig.2).

In case of error, a message is displayed in red.

Go to 

Users

 (fig.1), select “

New

”(fig.2) and then fill the form (Name, category, card

number...)(fig.3).

Open a browser and type the IP of the WS4-4D controller and you will be prompted to the

login page.

User Name: 

admin

Password: 

WS4

 followed by 

Dash

 and the 

Serial Number

 (ex. 

WS4-110034

) just like the

image below, all in capital letters without space.

QUICK USER GUIDE

• Capacity:  

 

 

2500 Users

• Events:  

 

 

50000 max.

• Doors:  

 

 

4 (max. 20 doors in same network)

• Readers: 

 

  4

• Door contact inputs:    

4

• Push button inputs:  

 

4

• Auxiliary Inputs:  

 

2 (emergency, vehicle detection)

• Auxiliary Outputs:  

 

2 (alarm, storing alarm status, presence)

• Power supply:    

 

120 to 240 V AC, 100 VA-1.52A with fuse (1 A)

• Supply for the readers:   

225 mA each max.

• Supply for the locks:    

600 mA each max.

• Relay characteristics:    

2A/48 VAC/DC#

• Processor:  

 

 

ARM A5 - 528 Mhz

• Memory:  

 

 

64 MB Ram DDR2 133 Mhz

• TCP/IP connection:  

 

10/100/1000 Base-T – HTTP or HTTPS

• Housing dimensions:    

350 x 250 x 80 mm

• Operating temperature:  

0 °C to +50 °C

• Humidity:  

 

 

0% to 85% (non-condensing)

• Tamper: 

 

  Yes

• Wiegand readers connection:   Yes, via Wiegand to RS485 converter - WS4-CNV

• Elevator feature:  

 

Yes, 2 elevators per installation, each - 24 floors

• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV

The WS4-4D does not have default IP address. By default is set to DHCP. There are 2

methods to connect to and configure WS4-4D - LAN and Standalone method.

In this configuration, the network’s DHCP server will assign an IP address to your WS4-4D

In this configuration, the WS4-4D will assign an IP address to your PC. The PC must be set to obtain IP

address automatically.

(For use in a home or business LAN network)

(For standalone use - without LAN network)

1. Put the DIP switch 1 in position OFF.

2. Connect a cable from your network to the ethernet connector of WS4-4D.

3. Open a web browser and enter http://ws4 followed dash and the serial number of

the WS4-4D controller

1.  Put the DIP switch 1 in position ON.

2. Connect a cable from your PC directly to the ethernet connector of WS4-4D.

3. Open a web browser and enter the following IP - 192.168.50.100, then put the login

credentials like explained above

DIP Switch 4 allows a complete re-initialization of the system. To

do this, switch this dip switch 

3 times OFF - ON - OFF

 within 

10

seconds.

DIP Switch 4 allows to log into the system as an administrator if

login or password is forgotten. Toggle this dip switch 

ON

 for 

about 

15 seconds

, then back to OFF. The system will then allow, 

for 5 minutes, to connect (from the local network only) with the 

default login and password.

Go to “Doors”, select the reader(fig.2) and then select the type of the reader in the

field ”Card”. (fig.3). While off line, red LED blinks fast and buzzer beeps continuously.

Once communication is established, the red LED and the buzzer stop. Green LED

starts to blink continuously. If you want to stop the green LED, go to Settings/System

Options and select for the backlight ON or OFF (not default) fig.4

v.a4

fig.1

fig.3

fig.5

fig.1

fig.2

Switch

Master/

Slave

Master

DIP switch 2

OFF

Slave 1

DIP switch 2

ON

Slave 9

DIP switch 2

ON

fig.3

fig.6

fig.4

fig.2

fig.1

fig.2

WS4-4D is a 4 door control unit designed to operate with readers with RS485 output.

There is no need to install any software. There is no need to have a dedicated PC

either. Everything is available online and the operators just need to register with

controller’s serial number to start using the software application.

NL

DE

ES

IT

FR

EN

Summary of Contents for WS4-4D

Page 1: ...nsions 350 x 250 x 80 mm Operating temperature 0 C to 50 C Humidity 0 to 85 non condensing Tamper Yes Wiegand readers connection Yes via Wiegand to RS485 converter WS4 CNV Elevator feature Yes 2 elevators per installation each 24 floors Interlock Anti pass back people counter presence system logs reports in CSV The WS4 4D does not have default IP address By default is set to DHCP There are 2 metho...

Page 2: ...he function of OUT1 and OUT2 can be configured in the software 4 In1 In2 Connect to GND by a volt free contact to activate the input 5 LIYCY cable twisted pair up to 80m If more than 80 m are needed then termination resistors 120 ohm may be required at both ends of the RS485 line while taking into consideration the lengths proposed on our web site 6 Alarm cable 2x0 22 7 The cross section of the ca...

Page 3: ...iegand Oui via Wiegand au convertisseur RS485 WS4 CNV Fonction ascenseur Oui 2 ascenseurs par installation 24 étages Interverrouillage anti retour compteur de personnes présence journaux système rapports en CSV Le WS4 4D ne comporte pas d adresse IP par défaut Il est réglé sur DHCP par défaut La connexion et la configuration du WS4 peuvent se faire selon deux méthodes différentes LAN et autonome D...

Page 4: ...trouver sur l adresse 0 et l autre sur l adresse 1 3 La fonction de SORTIE 1 et SORTIE 2 peut être configurée dans le logiciel 4 Entrée 1 et Entrée 2 raccorder à TERRE à l aide d un contact sans potentiel pour activer l entrée 5 Câble LIYCY paire torsadée jusqu à 80 m En cas de besoin de plus de 80 m des résistances de terminaison 120 ohms peuvent s avérer nécessaires aux deux extrémités de la lig...

Page 5: ...midità da 0 a 85 senza condensa Manomissione Sì Connessione lettore Wiegand Sì via Wiegand a convertitore RS485 WS4 CNV Funzione ascensore Sì 2 ascensori per installazione ciascuno 24 piani Interblocco Antiritorno contapersone presenza registri di sistema rapporti in CSV Il WS4 4D non ha un indirizzo IP predefinito È impostato su DHCP in maniera predefinita Per collegare e configurare WS4 4D sono ...

Page 6: ... una deve essere indirizzata su indirizzo 0 e l altra su indirizzo 1 3 La funzione di OUT1 e OUT2 può essere configurata nel software 4 In1 e In2 collegare a GND tramite un contatto privo di tensione per attivare l ingresso 5 Cavo LIYCY doppino fino a 80 m Se occorrono oltre 80 m può essere necessario applicare delle resistenze 120 ohm su entrambe le terminazioni della linea RS485 tenendo in consi...

Page 7: ...rol manual Sí Conexión de lectores Wiegand Sí a través de Wiegand al convertidor RS485 WS4 CNV Ascensores Sí 2 ascensores por instalación 24 pisos cada uno Enganche antirretorno contador de personas presencia registros del sistema informes en CSV La WS4 4D no tiene una dirección IP predeterminada sino que está establecido en DHCP Existen 2 métodos para conectar y configurar la WS4 4D LAN y un méto...

Page 8: ...l otro en la dirección 1 3 La función de la SALIDA 1 y la SALIDA 2 se puede configurar en el software 4 Entrada 1 y entrada 2 realice la conexión a TIERRA mediante un contacto sin tensión para activar la entrada 5 Cable LIYCY par trenzado hasta 80 m Si se necesitan más de 80 m se pueden requerir resistencias de terminación 120 ohmios a ambos extremos de la línea RS485 aunque se deben tener en cuen...

Page 9: ... 85 nicht kondensierend Sabotageschutz Ja Verbindung mit Wiegandleser Ja über Wiegand RS485 Konverter WS4 CNV Aufzugfunktion Ja 2 Aufzüge pro Installation jeweils 24 Stockwerke Schleusenfunktion Anti Passback Personenzähler Anwesenheit Systemlogs Berichte in CSV Der WS4 4D Controller verfügt nicht über eine automatisch zugewiesene IP Adresse Die Voreinstellung ist DHCP Es gibt 2 Möglichkeiten der ...

Page 10: ... sein 3 Die Funktion der Ausgänge OUT1 und OUT2 kann über die Software konfiguriert werden 4 Eingang In1 In2 Verbinden Sie GND mit einem potentialfreien Kontakt um den Eingang zu aktivieren 5 Paarverseiltes LiYCY Kabel max 80m Bei einer Entfernung von über 80 m werden Abschlusswiderstände 120 Ohm an beiden Enden der RS485 Datenleitung benötigt unterEinhaltungderaufunsererWebseitevorgeschlagenenLän...

Page 11: ...stemperatuur 0 C tot 50 C Vochtigheid 0 tot 85 zonder condensatie Sabotageschakelaar tamper Ja Aansluiting Wiegand lezers Ja via Wiegand op RS485 omzetter WS4 CNV Liftfunctie Ja 2 liften per installatie elk 24 etages Vergrendeling anti passback personenteller aanwezigheid systeemlogs rapporten in CSV De WS4 4D heeft geen standaard IP adres Deze is standaard ingesteld op DHCP Verbinding met en conf...

Page 12: ... 3 De functie van UIT1 en UIT2 kan in de software worden geconfigureerd 4 In1 en In2 Aansluiten op GND via een spanningsloos contact om de ingang te activeren 5 LIYCY kabel dubbeldraad tot 80 m Mogelijk zijn bij meer dan 80 m afsluitweerstanden 120 ohm vereist aan beide uiteinden van de RS485 lijn rekening houdend met de op onze website aanbevolen lengtes 6 Alarmkabel 2x0 22 7 De dwarsdoorsnede va...

Reviews: