background image

8.  Insert the 3/8” poly tubing into the nut and tighten the screw to the ball valve (item P in Diagram 1). 
9.  Insert the other end of the tube to the position marked 

Tank

 on the Quad

RO

 

10.  Turn on the ball valve (blue handle should be parallel to the tube) 

 
 

11.0

 

CONNECTING UP THE APPLIANCE 

1.  Screw the ¾” connector with 3/8” tube reducer on to both water inlets of the appliance  
2.  Measure the distance between the appliance and the Quad

RO

 system and cut a 3/8” poly tubing for the required length. 

3.  Connect the tubing to the Quad

 RO

 at the position marked 

APP

 (location F in diagram 1). 

4. 

Do not

 connect it to the steamer oven/coffee machine/appliance at this stage. 

 
 

12.0

 

CONNECTING

 

UP

 

FEEDING

 

WATER 

1. Measure 

the 

distance between the water feed valve and the R.O. system 

2.  Cut a 3/8” poly tubing with the length measured 
3.  Insert the tube to the connector B as shown in diagram 1. 
4.  Insert the other end of the tube to the 3/8 tube union tee adapter (item C in diagram 1) 
5.  Insert one end of the union tee connector to the inlet of the Triple Action System (item M) as shown in diagram 1 
6.  Insert a tube to the outlet of the Triple Action System (item M).   
7.  From the outlet of the Triple Action system (item M), insert the other end of the tube to the RAW water inlet of the 

appliance. 

8.  From the 3/8” union tee connector, insert the tube into the 3/8” OD ball valve of the Quad

RO

 system (item D) as 

shown in diagram 1 

 
 

13.0 START UP PROCEDURE

 

 
1.  With the tube that is connected at the position marked 

APP

 (location F in diagram 1), move the end of the tube to the drain 

cup. 

2.  Turn on water supply slowly. 
3.  Check for leaks. (If anything is leaking shut off water, repair, then start with step 1 again). 
4.  Within a few minutes (up to 10 minutes) the water will start to flow from the tube connected at the position marked 

APP

5.  Let the water run for 15 minutes. This flushes out the preservative in the membrane.  
6.  Turn off the water supply.  
7.  See Section 14 if you wish to adjust the TDS/water hardness of the water. 
8.  Insert the end of the tube that is connected at the position 

APP

 into the soft water inlet of the appliance. 

9.  Turn on the water supply - the tank will take about 1-2 hours to fill up (depending on the size of the tank and water pressure).   
 
 

14.0 ADJUSTING THE TDS (TOTAL DISSOLVED SOLID) IN THE WATER 

Note:  A TDS tester and water hardness test kit is required for testing the water hardness.  The TDS tester is used as a guide only.  
The water hardness test kit will be required to test the final hardness of the water.  The default set up for the system is to reject up 
to 96% of the impurities in the water.   
 
Some appliances require a certain level of water hardness in the water in order to function properly.  It is important that the installer 
is aware of the water requirement specification of the oven before starting the installation.  Any incorrect settings may result in 
serious damage to the appliance.  Please contact the water appliance manufacturer for details of the water hardness.   
 
Xsential will not be responsible for any wrong installation and set up of the Quad

RO

 system.  

1.  After installing the Quad

RO

 system.  Make sure that the Quad

RO

 system is not connected to the appliance. 

2.  Turn on the water supply. 
3.  Let the water run for 15 minutes as in section 12 step 5.   
4.  Measure the TDS (total dissolve solid) of the RO water with the TDS meter. 
5.  Increase/decrease the raw water supply to achieve the required setting by adjusting the TDS adjuster.   
6.  Once the required TDS level has been achieved with the TDS meter test the water hardness of the water using the water 

hardness kit.  

7.  Once the water hardness level is satisfactory, tighten the lower nut of the TDS adjuster.  This will prevent accidental 

adjustment of the TDS by people brushing up against the Quad

RO

 system.  

8.  Turn off water supply and connect the Quad

RO

 system to the appliance.  

 
 
15.0 SYSTEM MAINTENANCE AND FILTER CHANGE PROCEDURE

 

CAUTION FOR YOUR SAFETY:  Change the sediment and carbon filters regularly every 4-6 months and have the R.O. 
membrane checked annually.  Refer to the following table for the recommended filter change interval.

 

 

1.  Shut off the ball valve (item D in diagram 1) that is connected to the water supply. 
2.  Grab the cartridge that is to be changed with both hands and turn the cartridge anti-clockwise until it stops. 
3.  Pull the cartridge down to remove the cartridge. 
4.  Repeat steps 2-3 on the remaining cartridges.  
5.  All cartridges are labelled with a number on the top right hand corner.  Use the correct numbered cartridge for the 

replacement. 

6.  Insert and turn clockwise until the cartridge stops.  
7.  Once all cartridges have been replaced turn on the ball valve (item D in diagram 1).  

 
 

Summary of Contents for QuadRO

Page 1: ...D D R RO O Q QU UI IC CK K C CH HA AN NG GE E R RE EV VE ER RS SE E O OS SM MO OS SI IS S S SY YS ST TE EM MS S I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D M MA AI IN NT TE EN NA AN NC CE E M MA AN NU UA AL L ...

Page 2: ...M 8 0 INSTALLATION OF WASTEWATER DRAINAGE 9 0 INSTALLATION OF AX10 TS TRIPLE ACTION SYSTEM 10 0 INSTALLATION OF STORAGE TANK 11 0 CONNECTING UP THE APPLIANCE 12 0 CONNECTING UP FEEDING WATER 13 0 START UP PROCEDURE 14 0 ADJUSTING THE TDS TOTAL DISSOLVED SOLID IN THE WATER 15 0 SYSTEM MAINTENANCE AND FILTER CHANGE PROCEDURE 16 0 XSENTIAL TROUBLE SHOOTING GUIDE 17 0 AUTOMATIC SERVICE REMINDER ASR 18...

Page 3: ...s up to the individual to check for compatibility of Xsential s reverse osmosis system for the intended application Xsential will not be responsible for any wrong installation or water configuration 2 0 QUADRO QUICK CHANGE REVERSE OSMOSIS R O SYSTEM Read through the following instructions carefully before proceeding with the installation Be sure to follow any special plumbing codes in your area Co...

Page 4: ... position 2 Mark screw locations at the desired positions according to the marking and drill the holes 3 Turn the screws into the drill holes 4 Leave screw heads out a little 5 Hang the QuadRO R O system onto screws 6 Cut 4cm of the 3 8 tube and insert into IN of the water inlet location E in diagram 1 7 Insert the 3 8 OD ball valve item D in diagram 1 8 Make sure that the ball valve handle is par...

Page 5: ...4 0 ADJUSTING THE TDS TOTAL DISSOLVED SOLID IN THE WATER Note A TDS tester and water hardness test kit is required for testing the water hardness The TDS tester is used as a guide only The water hardness test kit will be required to test the final hardness of the water The default set up for the system is to reject up to 96 of the impurities in the water Some appliances require a certain level of ...

Page 6: ... very important that the owner checks the water quality regularly to ensure that the reverse osmosis system works properly Parts number Description Recommended service interval depending on the usage water quality QA11 CCF Sediment filter cartridge 3 6 months QA11 GAC Carbon filter cartridge 3 6 months QA11 ROM Reverse osmosis membrane 6 18 months QA11 TX Triple action cartridge 3 6 months Xsentia...

Page 7: ...uality with your local water authorities 2 Seasonality The concentration of salts in water increases in some seasons due to lack of rainfall while in other seasons the water may be less saline 3 Chemical treatment The amount of chemicals used to treat the water e g chlorine fluoride etc can lead to inconsistencies in the water quality Water is treated periodically by the local water authority lead...

Reviews: