1.2 Applications

The X|Smart_PSP power supply system and web based user interface was designed to meet numerous industry applications.    It 

gives the user much more functionality than just an interface to trigger wiping and cleaning of the enclosure dome.   With the 

integrated relays and power sensors, users can remotely control multiple accesory power ports and monitor power usage in real-

time.   A great tool for remote camera systems and especially o

ff

-grid powered systems.   

The X|Smart_PSP system is integrated into our X|Clear and X|Rain enlosure systems and is also available as an option in our X|Mod, 

X|Cold and X|Heat enclosure systems.  The next generation X|Smart_PSP will include an integrated UPS with battery backup power 

and integrated solar charge controller systems.

Example Applications Include Coastal Monitoring Cameras, Rainy Environments, O

ff

-Grid Powered Camera Locations, Remote 

Camera Applications and any installation that requires housing additional camera accesorry components.

1.3 Accessory Power Connections & Indicators

[2] 12VDC Accessory Power Ports

The X|Smart system has two 12VDC accessory power ports.   Each port is individually controlled (on/o

ff

) via the X|Smart web inter-

face.   Next to each accessory port is a green indicator LED which illuminates when power is available on the port.

[2] 24VDC Accessory Power Ports

The X|Smart system has two 24VDC accessory power ports.   Each port is individually controlled (on/o

ff

) via the X|Smart web inter-

face.   Next to each accesory port is a green indicator LED which illuminates when power is available on the port.

[1] 48VDC Accessory Power Over Ethernet Network Port

The X|Smart system has one 48VDC accessory POE network port which is controlled (on/o

ff

) via the X|Smart web interface.   Next 

to the POE port is a green indicator LED which illuminates when 48VDC power is available on the port.

[3] 10/100Mbps RJ45 Network Switch Ports

The X|Smart system has 3 non POE powered 10/100Mbps Network switch ports.   Two are accesible on the face of the X|Smart 

chassis while the third is underneath as indicated in Figure 1.4 above.

115/230VAC & 24VAC Power Inputs

The X|Smart power supply chassis takes either 115/230VAC or 24VAC input power.   The 115/230VAC power input is located on the 

face of the X|Smart power supply chassis as shown in Figure 1.4 above.   The 24VAC power input is located underneath the power 

supply chassis.

System LED

The System LED is a blue LED light which blinks every 5 seconds indicating the system is live and operating normally.  Allow ap-

proximately 10-15 seconds at power up for the System LED to start blinking.

[2] 12VDC Ports 

[2] 24VDC Ports 

System LED

[1] 48VDC POE Port

115/230VAC Input

[3] 10/100Mbps 

RJ45

Figure 1.4 - X|Smart_PSP Connections & Indicators

24VAC Input

Summary of Contents for XSmart PSP

Page 1: ...X Smart PSP Users Manual Revision 1 2...

Page 2: ...ures 7 1 2 Applications 8 1 3 Accessory Power Connections Indicators 8 1 4 Accessing the X Smart Web Interface 9 1 5 Good Wiring Practices 9 Section 2 Network Connection 10 Control Window 3 Overview 1...

Page 3: ...urchaser of this product X Stream Designs Inc assumes no responsibility for any errors that may appear in this document Whereas reasonable effort has been made to make the information in this document...

Page 4: ...s In such case freight and insurance shall be paid by the Customer MAKING A WARRANTY CLAIM 1 Customer must inform X Stream Designs as soon as the warranty claim arises by calling 1 858 768 2992 or sen...

Page 5: ...e X Smart system and access other devices on your local network As with any device installed on a network appropriate security precautions should be observed If the X Smart system is installed on the...

Page 6: ...sory power ports It can be controlled and or monitored over any IP network including private networks and the Internet Using a web browser users can control the dome wiping and cleaning process check...

Page 7: ...he user 3 available ports after populating the up link port with your network connection The 5th port connects to the integrated Linux embedded controller Power Supply Fans 2 Integrated into the power...

Page 8: ...cator LED which illuminates when power is available on the port 2 24VDC Accessory Power Ports The X Smart system has two 24VDC accessory power ports Each port is individually controlled on off via the...

Page 9: ...order to access the system from outside of your local network 1 5 Good Wiring Practices CAUTION MAKE SURE THAT POWER IS COMPLETELY OFF BEFORE WIRING MIS WIRING OR MIS CONFIGURATION COULD CAUSE PERMANE...

Page 10: ...This can be done direct or through a network switch Figure 2 1 2 It is suggested that no other devices are connected to the network if connecting through a switch to avoid potential IP Address confli...

Page 11: ...hin the control window that you monitor power and temperatures control the CID washing and wiping functions and power on and off accessory power ports The system by default does not require a username...

Page 12: ...Control Interface tab RTMP URL setttings are entered in the System Settings tab This feature DOES NOT allow you to display live video from typical IP net work cameras unless they support RTMP streami...

Page 13: ...id bottle is not emptied pre maturely and the Wipe Every function is not wiping a dry dome which can lead to surface scratches on the dome lens Figure 3 3 Interval Selection Page 13 X Stream Designs I...

Page 14: ...Control The enclosure heating system is set to AUTO and 10 C 50 F by default The selectable options are OFF or AUTO If OFF is selected the Internal Heater Lower Limit value is not selectable If Heat i...

Page 15: ...d date in the Status Pane Simply enter the desired text into the text input box and mouse click the update button The user has the option to display or not display the System Name field in the status...

Page 16: ...To enter a hyperlink URL for quick web access to accessory power port devices click on hyperlink icon to the left of the Custom Name text input box Figure 4 4 1 A window will appear Figure 4 4 2 allo...

Page 17: ...d the configuration options are explained below in detail Figure 4 7 System System The System section of the SYSTEM SETTINGS displays the current Firmware Version and allows the user to update the fir...

Page 18: ...network settings of the X Smart_PSP sys tem It is suggested to contact the administrator of your network for these settings prior to changing these settings and connecting to your network Selecting DH...

Page 19: ...e Stream Player The Live Stream Player section of the SYSTEM SETTINGS tab allows the user to enter RTMP Live Stream URI parameters Enter the following parameters then mouse click the Update button to...

Page 20: ...Lens XSD RDL Replacement Fixed Dome Lens Replacement Fixed Dome Lens XSD FDL XSD Camera Mounting Plate XSD Camera Mounting Plate XSD CMP XSD _L Extended Camera Mounting Tray Convert your X Model short...

Reviews: