DS800 Page 5 

Front Panel Functions 

 

 

1. 

Isolated Outputs

 – two identical transformer balanced outputs featuring high 

voltage isolation, for use as broadcast or recording feeds or wherever 
independent outputs are  required.  These connections are wired as follows :- 
Pin 1 = No Connection, Pin 2 = Hot, Pin 3 = Cold. 

2. 

As Above

3. 

Gain Switch

 – sets the channel gain to +10dB, +20dB, +30dB, +40dB or 

+50dB. See Mic/Line switch below. 

4. 

Mic/Line

 – when in the ‘Line’ position the input is padded by 20dB and the input 

impeadance changes to >10k Ohms. 

5. 

48V 

– when selected applies 48V phantom power to the input XLR, for 

condenser microphones or D.I. boxes. The LED is lit when active. 

6. 

Meter

 – 5 segment level meter showing the level below clipping. Note: the red 

LED lights up 6dB’s below actual clipping with a sine wave. 

7. 

Listen

 – when selected the channel will be summed on to the ‘Solo’ bus, which 

is routed to the headphone socket and ‘Solo Out’ XLR. 

8. 

Pad (-10dB)

 – indicates 48V phantom power detected on the output ‘Mon’ XLR, 

which will automactically switch in a 10dB pad on the channel. 

9. 

Headphone Level

 – controls the level of the headphone output. 

10. 

Headphone Socket

11. 

Power

 – power indicator. 

Summary of Contents for DS800

Page 1: ......

Page 2: ......

Page 3: ...t Safety Information 2 Thanks 3 Unpacking the DS800 3 Introduction 4 Front Panel Functions 5 Rear Panel Functions 6 Block Diagram 7 Grounding 8 Cooling 8 System Wiring 9 Bussing Option 9 Specification...

Page 4: ...LECTRIQUE NE PAS ENLEVER NE PAS EXPOSER A LA PLUIE NI A L HUMITE It should not be necessary to remove any protective earth or signal cable shield connections Do not defeat the purpose of the polarized...

Page 5: ...class performance and reliability If you would like further information about this or any other XTA product please contact us We look forward to helping you in the near future XTA Electronics Ltd Unp...

Page 6: ...as been carefully engineered to overcome the limitations and problems of conventional splitters and provides a new level of performance and reliability The XTA DS800 Mic Line Distribution System is a...

Page 7: ...the input impeadance changes to 10k Ohms 5 48V when selected applies 48V phantom power to the input XLR for condenser microphones or D I boxes The LED is lit when active 6 Meter 5 segment level meter...

Page 8: ...ic and condenser microphones and line level inputs 4 Solo Bus Out XLR used for multiple unit applications normally connected to the Solo Bus In XLR of the unit above in the rack When configured in thi...

Page 9: ...DS800 Page 7 Block Diagram...

Page 10: ...d be interfaced via a suitable balancing system e g D I box or balancing transformer 2 Use high quality screened cable and multi core cable throughout the system 3 Run all the power for back line moni...

Page 11: ...is connected to it s corresponding output drive section which effectively has 4 outputs two isolateds FOH and MON Jumper links that are assessable internally are provided that enable this configuratio...

Page 12: ...DS800 Page 10 By swapping the jumper links numerous configurations are possible Shown below are two possible set ups...

Page 13: ...20Hz 20kHz Equivalent Input Noise 10dB Gain 112dBm 20Hz 20kHz Unweighted 20dB Gain 117dBm 30dB Gain 120dBm 40dB Gain 120dBm Distortion 0 01 1kHz 4dB output Connectors Inputs 3 pin female XLR Pin 1 Gnd...

Page 14: ...cts which prove to be defective provided that the product is returned shipping prepaid to an authorised XTA service facility Defects caused by unauthorised modifications misuse negligence act of God o...