background image

The 4180x is a four channel amplifier which combines

unique performance features with outstanding design flexi-

bility to provide a single chassis “system solution” for most

mobile audio applications. With its on-board crossover, a high

performance bi-amplified system is easily configured.

By utilizing the on-board crossover’s four (4) RCA line outputs, you can steer

specific frequency ranges to additional amplifiers, thus eliminating the need

for external, active crossover components.

As with all Xtant “X” Series amplifiers, the 4180x incorporates an on-board

noise gate, forced convection thermal management system, and a Pulse Width

Modulated power supply for high efficiency and unsurpassed reliability. All

these features are encased in Xtant’s exclusive finish of stainless steel and

copper!

Standard Features

Forced Convection Cooling:

All Xtant “x” Series

amplifiers employ forced convection cooling for thermal man-

agement. An on-board thermal sensing circuit regulates fan

speed to maintain optimum operating temperature.

PWM Power Supply:

All Xtant “x” Series amplifiers fea-

ture a fully regulated, Pulse Width Modulated power supply.

This supply technology provides high efficiency and consistent

output performance even when battery voltage is less than optimum.

Crossover:

12 dB per octave “Butterworth” filter network with selectable

Bypass (Full Range), High Pass, or Low Pass modes of operation. Frequency selec-

tion is via a 12 pin Frequency Module (SIP). The amplifier is shipped with a 90 Hz

SIP installed, 13 other frequencies are available from your Xtant Dealer. Refer to

page 7 of this manual for a list of the available frequencies.

Noise Gate:

Provides deep muting when no musical signal is present. Features

include adjustable threshold and bypass switch.

Balanced / Floating Input:

All “x” Series amplifiers offer input docking

ports which accept the optional Balanced Line Module (BLM-1). When added to

the input stage, this circuitry helps to eliminate “system noise” associated with

“ground-loops”.

Modular Expansion Port:

All Xtant amplifiers are supplied with a mod-

ular port used for docking any of Xtant’s signal processing modules.

Protection Circuitry:

Both Thermal and Overcurrent protection has been

incorporated into all Xtant amplifiers. In the event of a problem, the amplifier will

reduce its power to maintain operation.

Status LEDs:

Four LEDs, visible through the cover, indicate operational status

of all Xtant amplifiers. The red LED illuminates when the amplifier is “ON”, the

green LED indicates when the noise gate is open, the yellow LED indicates that

overcurrent protection is employed and the orange LED indicates that the ther-

mal protection circuit is operational.

5

Summary of Contents for 4180X

Page 1: ......

Page 2: ...participle of xstare to stand forth Second origin Prescott AZ U S A Ntl Frst Cmp 1994 v to xtantify to stand up and be heard 3 noun XTANT applied creativity esp a company of people united to apply original thinking to continually advance the spectrum of extraordi narily vivid sound reproduction to apply innovative thought and action to questions previously considered resolved Xtant Technologies 76...

Page 3: ...re not presented in this owners manual All Authorized Xtant Select Dealers have been chosen for their expertise in sys tem design and advanced installation capabilities and Xtant highly recom mends that you have all of your mobile audio products professionally installed If however you choose to install your Xtant amplifier yourself please refer to the Installer s Reference prior to installation Wi...

Page 4: ... Safeguards 3 Xtant 4180x 5 Specifications 6 Electronic Crossover 7 Optional Accessory Modules 8 Maintenance 9 CustomerRelations TechnicalServices 10 Warranty 11 Owner s Installation Log 12 Installer s Reference Insert ...

Page 5: ...ltage is less than optimum Crossover 12 dB per octave Butterworth filter network with selectable Bypass Full Range High Pass or Low Pass modes of operation Frequency selec tion is via a 12 pin Frequency Module SIP The amplifier is shipped with a 90 Hz SIP installed 13 other frequencies are available from your Xtant Dealer Refer to page 7 of this manual for a list of the available frequencies Noise...

Page 6: ...ndwidth 1 volt sensitivity Damping Factor 200 100 Hz with 4Ω load Input Sensitivity 100 mV to 8 5 V RMS Unbalanced Source 100 mV to 17 V RMS Balanced Source Input to Line Output Gain 0 dB 20 dB Selectable in 10 dB steps On Board Crossover 12 dB per Octave Butterworth Module Port s 2 Accessory and 2 Balanced Line Power Supply Fully Regulated PWM Operational Voltage 11 to 15 Volts Fusing 60 Amp Size...

Page 7: ...tures two on board header jumpers one for the amplifier and one for the RCA line out puts which allow you to select Bypass Full Range High Pass and or Low Pass modes The ix Series models offer an additional Band Pass selection When chosen the Band Pass selection is available via the Low Pass jumper position for the RCA line outputs The following Frequency Modules SIPs are available from your Xtant...

Page 8: ...ing a wide variety of bandwidth adjustment to address the subtle tuning requirements common to mobile audio systems All 2 channel Xtant amplifiers can accept one PQM 1 All 3 4 channel amplifiers will accept two PQM 1 modules if desired one PQM 1 per 2 channels of input 24 DB OCTAVE CROSSOVER MODULE CM 24X The CM 24X upgrades the standard on board crossovers provided on all Xtant ix and x Series am...

Page 9: ...dust particles DO NOT use a high pressure source brush or any similar device to clean the circuit board Cleaning the Amplifier Every 30 days A Clean the stainless steel cover with a light dust cloth For a more thorough cleaning use window cleaner that is ammonia free Apply the cleaner to the cloth not the amplifier and wipe the surface Take care not to catch the cloth on the copper mesh Caution Do...

Page 10: ...e designed in the event of a problem to minimize the amount of your down time and inconvenience It is our commitment to service and return such product in no more than two 2 working days from the time Xtant receives the equipment Please consider weekends or holidays which may fall within the time period when estimat ing the return date of serviced product For technical assistance and information r...

Page 11: ...ect 5 The provisions of this warranty shall not apply to any Xtant unit used for a purpose for which it is not designed which has been repaired or altered in any way or which has been connected installed or adjust ed other than in accordance with the instructions furnished in Xtant s owner s manual Nor shall this war ranty apply to any part which has been subject to misuse neglect or accident 6 Xt...

Page 12: ...SETTING CIRCLE JUMPER SETTING Amplifier Amplifier byp high low byp high low rca outputs rca outputs byp high low byp high low frequency value frequency value SIP High Pass FQ SIP High Pass FQ sip low pass FQ sip low pass FQ output gain adjustment noise gate adjustment switch on off threshold position DRAW ARROW POSITION DRAW ARROW POSITION Accessory modules CIRCLE SETTING CM 24X f r o n t r e a r ...