background image

 
 

 

3. NMS (network management system) Configuration. The corresponding configuration need to be done so 

that the NC can be monitored through NMS. For example, The given IP address is 10.86.5.100, and the 

subnet mask is 255.255.252.0, management is VLAN 52, SNMP’s community name is test. 

 

GD.LINK>

 enable                                                               

  /*access initial mode*/

 

Password

: admin                                                                     

/*enter password*/ 

GD.LINK# 

configure terminal                                               

/*access overall configuration mode*/ 

GD.LINK(config)# 

snmp community test                             

/*configure SNMP parameter’s community name to be test*/

 

GD.LINK(config)#

 snmp server start                                   

/*enable SNMP server*/ 

GD.LINK(config)# 

interface manage-interface                     

/*access interface configuration mode*/ 

 

GD.LINK(config-if)# 

ip-address 10.86.5.100/22 gateway 10.86.4.1     

 

/*configure IP address to be 10.86.5.100, 22 represents the   

subnet mask bits, 10.86.4.1 is default gateway address*/ 

 

GD.LINK(config-if)# 

vlan 52                                               

/*configure the management VLAN as Vlan 52*/ 

GD.LINK(config-if)#

 end                                                     

/*back to privilege configuration mode*/ 

GD.LINK#

 write                                                                   

  /*save the configuration*/ 

GD.LINK# 

show running-config                                           

/*check the finished configured program*/ 

configure terminal 

snmp community test 

snmp server start 

exit 

 

configure terminal 

end 

 

configure terminal 

interface manage-interface 

  ip-address 10.86.5.100/22    gateway 10.86.4.1 

  vlan 52 

exit 

end 

 

configure terminal 

port coax 

exit 

end 

 

configure terminal 

headend 

exit 

end 

 

Summary of Contents for XL-MB103SW

Page 1: ...XL MB103SW MoCA Ethernet bridge User s Guide ...

Page 2: ...xample in a community VOD service is VLAN 100 IP service is VLAN 200 and if CPE s port 1 and port 3 are equipped for VOD service port 2 and port 4 are equipped for IP service the configuration should be made as bellow GD LINK enable access initial mode Password admin enter password GD LINK configure terminal enter overall configuration mode GD LINK config cpe template enable open the template conf...

Page 3: ...te enable cpe template 8021q on cpe template port 1 enable cpe template port 1 access vlan 100 cpe template port 2 enable cpe template port 2 access vlan 200 cpe template port 3 enable cpe template port 3 access vlan 100 cpe template port 4 enable cpe template port 4 access vlan 200 end configure terminal interface manage interface exit end configure terminal port coax exit end configure terminal ...

Page 4: ...D LINK config interface manage interface access interface configuration mode GD LINK config if ip address 10 86 5 100 22 gateway 10 86 4 1 configure IP address to be 10 86 5 100 22 represents the subnet mask bits 10 86 4 1 is default gateway address GD LINK config if vlan 52 configure the management VLAN as Vlan 52 GD LINK config if end back to privilege configuration mode GD LINK write save the c...

Page 5: ... finished program configure terminal exit configure terminal end configure terminal interface manage interface exit end configure terminal port coax exit end configure terminal headend frequency 1100 exit end This configuration is mainly for solving the basic interference problems Use show online command under NC to observe whether the NC s attenuation value is in a normal range or not If the forw...

Page 6: ...r 1 cpe port 1 enable Enable to set up CPE port 1 GD LINK config user 1 cpe port 1 access vlan xx Set up VLAN of CPE port 1 GD LINK config user 1 end Exit to privilege mode GD LINK show run Check configuration GD LINK write Save Configuration 6 Change login password GD LINK enable Access privilege mode Password admin Enter password admin GD LINK con t Access overall configuration mode GD LINK conf...

Page 7: ...CPE MAC Add Forwarding rate Receiving Rate Actual Attenuation Error Packet Number ...