background image

2018/5/4V1.0+V1.0 

32

 

To set up the Fit Test 

  Press the FIT TEST button repeatedly until the FIT TEST option appears in the 

message center. Press ENTER to select the FIT TEST option. 

  The message center will prompt for a user weight, age and gender . Use the 

NUMERIC KEYS or UP/DOWN ARROW KEYS to input the weight, age and 

gender. Press ENTER to confirm. 

  The message center will next prompt for a workout level (ENTER SPEED)(2-4.5 

mph). Consult the following recommended fit test level chart for an appropriate 

effort level based on your age, gender and activity level. Use the NUMERIC 

KEYS or UP/DOWN SPEED ARROW KEYS to enter the corresponding level. 

After the five-minute FIT TEST is completed, a FIT TEST score will be displayed. 

Fit Test Program Suggested Exertion Levels 

 Inactive 

Active 

Very 

Active 

2-3mph 3-4mph 3.5-4.5mph 

Treadmill Fit Test 

Level 

3.2-4.8kph 4.8-6.4kph 5.6-7.2kph 

NOTE: Treadmill will incline to 5% after a one minute warm-up. 

Suggested exertion levels should be used as a guideline for setting up the Fit Test 

program. The goal is to elevate the user's heart rate to a level that is between 60%-85% of 

their theoretical maximum heart rate. 

Active Levels And Range   

Lower Half of Range 

Upper Half of Range 

higher age 

lower age 

lower weight   

higher weight * 

shorter taller 

In cases of excessive weight, use lower half of range. 

The program will not accept: 

Summary of Contents for TL200

Page 1: ...TREADMILL TL200 OWNER S MANUAL...

Page 2: ...Adjustment 8 2 5 Machine movement 9 3 Assembly Instructions 10 3 1 Pre Assembly Check List 10 3 2 Hardware Pack 11 3 3 Assembly steps 12 4 COMPUTER OPERATION INSTRUCTION 17 4 1 Computer structure 17 5...

Page 3: ...2018 5 4V1 0 V1 0 2 1 Overview Drawing...

Page 4: ...valids or disabled persons 3 Be sure to use the product only for its intended use as described in this manual Do not use any attachment not recommended by the manufacturer in order to avoid any danger...

Page 5: ...e appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 15 Incorrect or excessive training may cause injuries t health may...

Page 6: ...4V1 0 V1 0 5 23 Before using this product you should step on the it then turn on the product Do not turn on the treadmill before step on it 24 Running surface Width dimensions 560 1475mm 25 Customer A...

Page 7: ...res low pressure wires and underground wires should be transported separately and can t connect with or twist other wires Improper connection of the grounding plug can result in the risk of electric s...

Page 8: ...laced on uneven ground The level adjustment method is as follows 1 Turn A counter clockwise to loosen it 2 Adjust B to the proper height 3 Turn A clockwise to tighten it 4 The left side adjustment met...

Page 9: ...t is running properly First determine that the power supply meets the requirements After the power is plugged in start the treadmill press the QUICK START button and then press the up speed key to inc...

Page 10: ...2018 5 4V1 0 V1 0 9 2 5 Machine movement When the machine is moving you can put the handling tube K into the back of the box to move the machine...

Page 11: ...lt and the HRC will show in Pulse windows 3 1 Pre Assembly Check List ITEM Description Qty ITEM Description Qty A Treadmill frame 1 G Electronic meter 1 B Treadmill s hand stand pipe left 1 H Water cu...

Page 12: ...r 5x35x115mm 1 c Washer 10x 25x2 0t 16 l Type T wrench 6mm 1 d Inner hexagon steel screw M8x20 of socket head 4 m Type T wrench 10mm 1 e Spring washer M8 8 n Power cord switch sleeve 1 f Washer 8x 19x...

Page 13: ...to the left and right treadmill s hand stand pipes to tighten the wires on both sides of the platform Pass it through the square hole at the bottom of the left and right treadmill s hand stand pipes...

Page 14: ...eft and right treadmill s hand stand pipes and go through the pipe end 2 Use screw d spring washer e washer f to lock the left and right handrail pipes D E tightly as shown in the figure and fix them...

Page 15: ...the wires of the water cup frame After connecting Cable the Cable middle plastic sleeve shall be inserted into the Cable metal connector 2 Lock with screw g and washer b c but not tightly Confirm tha...

Page 16: ...ic meter tightly and fix it on the water cup frame After connecting Cable the Cable middle plastic sleeve shall be inserted into the Cable metal connector Cover the Electronic meter decorative cover L...

Page 17: ...ative covers I J and tighten them with screws i Insert the power cord into the power cord socket according to the figure position Cover the power cord switch sleeve n and lock it tightly with screws o...

Page 18: ...1 Computer structure A WORKOUT PROFILE WINDOW It shows the change status of slope Cursor represents the percentage of inclination B MESSAGE CENTER It displays the operation steps of each procedure as...

Page 19: ...mit 0 5mph 0 8Kph STEP 0 1 mph D ENTER It is used to set up the procedure s digital determination or project selection such as exercise time speed weight distance moving target and gender and target h...

Page 20: ...uring exercise the speed makes 3 6 9 quick switch K Treadmill mode Press this button and start the machine then it enters the function of the treadmill Under standby status switches between treadmill...

Page 21: ...s to improve cardiovascular Function On the right is the picture shows age and its corresponding heart beat times Heart rate exercise includes three modes Hill Heart Rate Interval Heart Rate Intensive...

Page 22: ...logy is used to transmit the pulse signals to control board Chest belt is not the necessary attachment You can purchase if you need Figure middle electrode position and wearing ways of chest belt The...

Page 23: ...ption exact make sure the weight of the user inclination and speed The preset inclination is 0 and you can adjust it by pressing incline up down key or incline instant key and adjust speed by pressing...

Page 24: ...70 Keep this rate in the running for one minute and then reduce the incline to reduce the rate to 65 for one minute Each heart rate shall keep for one minute Do the exercises in the program operation...

Page 25: ...similar to the heart rate control program and the differences are firstly the heart rate goals are 80 of the maximum heart rate Target heart rate will be obtained based on user s information provided...

Page 26: ...to the changes in short distance racing In the running period confirmation shall be made that the breast belt sensor is correctly worn or the heart rate sensor on the handle is grasped tightly Otherw...

Page 27: ...n until the end of the set program time If the user does not reach the two heart rate goals after 5 minutes the information display screen will give prompt for acceleration or deceleration and the det...

Page 28: ...than 5 minutes the cooling time is 1 minute if between 5 to 15 minutes the cooling time is 3 minutes and if higher than 15 minutes the cooling time is 5 minutes After cooling if the user requires to c...

Page 29: ...Therefore there is no prompt displayed to test the heart rate In the running period the user shall wear the breast belt sensor or grasp the heart rate sensor on the handler Warm up Gradually increase...

Page 30: ...onds If the program time is 15 minutes the interval time is set to be 45 seconds 20 95 minutes The default continued time is 60seconds for every default interval If user want to extend the time of eve...

Page 31: ...eter controls and displays the heart rate and automatically adjusts the inclination of the running machine to keep the heart rate as the targeted rate This program is for warming up exercise and will...

Page 32: ...stops the operation FIT TEST Fit test program It s applied to test the angiocarpy function and supervise the improvement of the angiocarpy every four and six weeks As the test result is calculated acc...

Page 33: ...or UP DOWN SPEED ARROW KEYS to enter the corresponding level After the five minute FIT TEST is completed a FIT TEST score will be displayed Fit Test Program Suggested Exertion Levels Inactive Active...

Page 34: ...ke the Fit Test under similar circumstances each time Your heart rate is dependent on many factors including amount of sleep the previous night at least seven hours is recommended time of day time you...

Page 35: ...3 38 4 45 1 45 2 50 9 51 0 55 9 55 9 20 29 33 0 33 0 36 4 36 5 42 4 42 5 46 4 46 5 52 4 52 4 30 39 31 5 31 5 35 4 35 5 40 9 41 0 44 9 45 0 49 4 49 4 40 49 30 2 30 2 33 5 33 6 38 9 39 0 43 7 43 8 48 0...

Page 36: ...rkout include selecting a level The word level refers to a range of incline percentages The treadmill features 20 levels The electronic meter displays the above information in the form of column graph...

Page 37: ...he frequency converter 4 The control line is in fault Replace the control line 5 The electronic meter is in fault The electronic meter is in fault 6 Energy saving small board failure Change energy sav...

Page 38: ...cy converter motor is abnormal Replace the motor or frequency converter E11 The overload of frequency converter is abnormal Perling adds oil and the transducer is changed E12 The overload of frequency...

Page 39: ...s emergency stop Replace the frequency converter control line and electronic meter E41 The frequency converter displays high temperature Add lubricating oil in the running machine and replace frequenc...

Page 40: ...8 Metric imperial conversion 1 The standby screen is shown as follows 2 Press STOP ENTER key to enter engineering mode after 8 seconds 3 Press ENTER key and enter metric imperial modification screen...

Page 41: ...2018 5 4V1 0 V1 0 40 4 Use SPEED key to convert metric imperial system 5 Press ENTER key and the 4th screen can return to standby mode...

Reviews: