background image

TROUBLE SHOOTING 

Warning: Before any maintenance or repair work, you must cul off the power supply and 

ensure that the air tank is pressure-free, otherwise it is very easy to cause injury! 

Problem 

The motor does 

not start and 

without 

any noise 

The motor does 

not start or 

starts slowly,with 

a humming noise 

The overload 

protector cuts 

off the power 

repeatedly 

Pressure drops 

in the tank 

The exhaust 

gas has a 

high humidity 

The motor does 

not stop 

Machine with 

High vibration 

Can not reach 

the max working 

pressure 

Possible cause 

Solution 

No Power supply 

Pressure switch is off 

Under overload protection 

Pressure switch faulty 

Check the plug and the power supply 

turn on the pressure switch 

Press the red reset button to start afler 

the machine cooled down 
Replace the pressure switch 

Stator faulty 

Replace the stator 

Low voltage supply 

Place the air compressor in a 

well-ventilated place 

Short circuit or open circuit 

of motor coiling 

Contact dealer 

Check valve or pressure 

switch faulty 

Low voltage supply 
Poor ventilation, 

too high temperature 
Wrong installation of fan 

Contact dealer 

Check the input voltage, can not 10% 

lower than the rated voltage 

lower 

Check 

!han 

the 

the 

input 

rated 

voltage

vol t age 

can not 10%

Check the fan  and install it in 

the correct direction 

Air leaks at connections 

Drain valve is open or loose 

Check each connection,tighten 

leaky connection 

Tighten the drain valve 

Air leaks at check valve 

Remove and clean, if still not work, 

Replace the check valve 

A lot of water in the tank 

The workin environment

with too hig � humidity 

Drain the water in the tank 

Move the air compressor to a place with 

low humidity,or use an oil-water separator 

Pressure switch faulty 

Air leakage, can not reach 

the max pressure 

Replace the pressure switch 

Check and tighten the leaky connection 

Check and tighten 

Loose fasteners 

The interna! parts of the air 

compressor are aging or damaged  Replace foot or shock pad 

Cushion foot or shock 

pad damaged 

Drain valve is open or loose 

Replace aging or damaged parts 

Tighten the drain valve 

Air filter blocked 

Air leakage 

Poor valve function or foreign 

matter or air leakage 

Clean or replace the filter element 

Check and tighten 

Clean or replace 

Excessive wear of piston rings 

Replace the piston ring 

Summary of Contents for XT2008

Page 1: ...OR BEZOLEJOV Model 2 900F8 Nap t 230V 50Hz P kon 900 W Ot ky 2800 ot min Max tlak 8 bar Objem n doby 6 l V stup vzduchu 1 4 Pln c v kon 70 l min Hladina akustick ho v konu LwA 70 dB Izolace t da ochra...

Page 2: ...h te p ipevn n k ot ej c se sti elektrick ho n ad m e b t p inou poran n osob e Pracujte jen tam kam bezpe n dos hnete V dy udr ujte stabiln postoj a rovnov hu Budete tak l pe ovl dat elektrick n ad v...

Page 3: ...o roubu Nastaven tlaku nicm n nem te nebo jsou tyto hodnoty nastaveny ji z v roby V opa n m p pad hroz po kozen za zen 9 Za zen m vlastn zabudovanou ochranu proti p ep t a p et en Ochrana proti p et e...

Page 4: ...l Po et 1 Vzduchov filtr 2 2 Dr adlo 1 3 Vrut 2 4 roub 4 5 Podlo ka nohy 4 Vysok pr tok vzduchu Vysoce v konn tich motor ty i rovn ochrany Vysok tlak Bezolejov N zk hlu nost N zk vibrace N zk n r st t...

Page 5: ...adne Za zen m p sn po adavky na minim ln pr ez elektrick ho p vodn ho kabelu Detaily t kaj c se pr ezu kabelu najdete v technick m listu tohoto manu lu Aby bylo mo n p edch zet kol s n nap t a ztr t v...

Page 6: ...ho po kozen 2 Manometr Obr E Vzduchov kompresor je po dobu spu t n automaticky ovl d n tlakov m sp na em Kdy hodnota tlaku dos hne maxim ln hodnoty automaticky dojde k jeho vypnut Jakmile hodnota tlak...

Page 7: ...ev rejte vypou t c ventil a nechte vyt ct p ebyte nou vodu denn nebo po ka d m pou it p stroje P i vypou t n mus b t tlak ve vzduchov n dob men ne 1 bar 4 Ka d t den kontrolujte citlivost pojistn ho v...

Page 8: ...nap t patn nainstalovan ventil tor Zkontrolujte ventil tor a namontujte do spr vn polohy Tlak v n dob kol s nik vzduchu v okol spoj Zkontrolujte v echny spoje ut hn te unikaj c spoje Vypou t c ventil...

Page 9: ...y Skrutka pr tla nej podlo ky ruba Pressure plate screw 21 V lec Valec cylinder Cylinder 22 roub vzduch ventilu Skrutka vzduch ventilu ruba Screw for air valve 23 Kovov v ztuha Kovov v stuha przek adk...

Page 10: ...k O kr ok O ring O ring 52 Pojistn ventil Poistn ventil zaw r kontrolny Check valve 53 V tla n trubice V tla n trubica rurka Discharging pipe 54 Tlakom r Tlakomer ci nieniomierz Pressure gauge 55 Tlak...

Page 11: ...Sch matick pohled 64...

Page 12: ...o pou it v bezpe nostn ch zna k ch 2012 12 01 SN EN ISO 4414 Pneumatika V eobecn pravidla a bezpe nostn po adavky na pneumatick syst my a jejich sou sti 2011 06 01 SN EN 61439 1 ed 2 Rozv d e n zk ho...

Page 13: ...EZOLEJOV Model 2 900F8 Nap tie 230V 50Hz Pr kon 900 W Ot ky 2800 ot min Max tlak 8 bar Objem n doby 6 l V stup vzduchu 1 4 Plniaci v kon 70 l min Hladina akustick ho v konu LwA 70 dB Izol cia trieda o...

Page 14: ...ies k v nemu poraneniu os b b Pou vajte ochrann pom cky V dy pou vajte ochranu o Ochrann pom cky ako napr Respir tor bezpe nostn obuv s proti mykovou pravou tvrd pokr vka hlavy alebo ochrana sluchu po...

Page 15: ...za chyby po dobu 24 mesiacov u pr vnick ch os b 12 mesiacov Reklam cie bud pos den na m reklama n m oddelen m pozri ni ie a uznan bezplatne oprav servis firmy XT line s r o Miestom pre uplatnenie rekl...

Page 16: ...et 1 Vzduchov filter 2 2 Dr adlo 1 3 Skrutka 2 4 Skrutka 4 5 Podlo ka nohy 4 Vysok prietok vzduchu Vysoko v konn tich motor tyri rovne ochrany Vysok tlak N zka hlu nos N zky n rast teploty N zke vibr...

Page 17: ...nevychladne Zariadenie m pr sne po iadavky na minim lny prierez elektrick ho pr vodn ho k bla Detaily t kaj ce sa prierezu k bla n jdete v technickom liste tohto manu lu Aby bolo mo n predch dza kol s...

Page 18: ...jeho po kodeniu 2 Manometer Obr E Vzduchov kompresor je po as spustenia automaticky ovl dan tlakov m sp na om Ke hodnota tlaku dosiahne maxim lnu hodnotu automaticky d jde k jeho vypnutiu Akon hle ho...

Page 19: ...kom 3 Otv rajte vyp ac ventil a nechajte vytiec prebyto n vodu denne alebo po ka dom pou it pr stroja Pri vyp an mus by tlak vo vzduchovej n dobe men ako 1 bar 4 Ka d t de kontrolujte citlivos poistn...

Page 20: ...o menovit nap tie Zle nain talovan ventil tor Skontrolujte ventil tor a namontujte do spr vnej polohy Tlak v n dobe kol e nik vzduchu v okol spojov Skontrolujte v etky spoje utiahnite unikaj ce spoje...

Page 21: ...OLEJOWY Model 2 900F8 Napi cie 230V 50Hz Moc 900 W Pr dko 2800 rpm Maksymalne ci nienie 8 bar Pojemno naczynia 6 l Wlot powietrza 1 4 Pokrycie mocy 70 l min Poziom mocy akustycznej LwA 70 dB Izolacja...

Page 22: ...c Nale y unika niezamierzonego uruchomienia Przed pod czeniem do r d a zasilania lub akumulatora nale y upewni si e prze cznik znajduje si w pozycji OFF d Nale y ubiera si prawid owo Nie nale y nosi l...

Page 23: ...ltr pow 2 2 r czka 1 3 wkr t 2 4 ruba 4 5 poduszka st p 4 Wysoki przep yw zasilania Wyciszony silnik o du ej pr dko ci 4 klasa ochrony wysokie ci nienie Niski d wi k Niski wzrost temperatury Niskie wi...

Page 24: ...z arkuszem specyfikacji tego podr cznika aby uzyska szczeg owe informacje Kabel zasilaj cy nie powinien by zbyt d ugi aby zapobiec nadmiernemu spadkowi napi cia i wp yn na wydajno maszyny Zalecana te...

Page 25: ...tr rys E Spr arka powietrza jest automatycznie sterowana przez wy cznik ci nieniowy podczas normalnej pracy Gdy ci nienie osi gnie warto maksymaln automatycznie zatrzyma si a gdy ci nienie spadnie do...

Page 26: ...ecze stwa musi on zosta wymieniony przez serwis producenta lub wykwalifikowan osob 3 Otw rz zaw r spustowy aby spuszcza wod codziennie lub po ka dym u yciu Podczas spuszczania ci nienie w zbiorniku po...

Page 27: ...ni napi cie znamionowe Nieprawid owa instalacja wentylatora Sprawd wentylator i zainstaluj go we w a ciwym kierunku Spadki ci nienia w zbiorniku Wycieki powietrza na po czeniach Sprawd ka de po czenie...

Page 28: ...OIL FREE Model 2 900F8 Voltage 230V 50Hz Power 900 W Speed 2800 rpm Max pressure 8 bar Vessel volume 6 l Outlet air 1 4 Filling power 70 l min Sound power level LwA 70 dB Insulation class protection I...

Page 29: ...nd face or dust mask Wear protective hearing equipment helmet and boots c Avoid unintentional starting Before connecting to power source or battery make sure the switch is at OFF position d Dress prop...

Page 30: ...o Parts Qty 1 Air filter 2 2 Handle 1 3 Screw 2 4 Bolt 4 5 Cushion foot 4 High flow supply High speed silenced motor Four protection High pressure Low noise Low temperature rise Low vibration Oil free...

Page 31: ...machine has strict requirements of the power cable Please refer to the specification sheet of this manual for details The power cable should not be too long to prevent excessive voltage drop and affec...

Page 32: ...Pic E The air compressor is automatically controlled by pressure switch during normal operation When the pressure reaches the maximum value it will automatically stop and when the pressure drops to th...

Page 33: ...acturer s maintenance department or qualified person 3 Open the drain valve to drain the water daily or after every use When draining the pressure in the air tank should be less than 1 bar 4 Check whe...

Page 34: ...n too high temperature Wrong installation of fan Contact dealer Check the input voltage can not 10 lower than the rated voltage lower Check han the the input rated voltage voltage can not 10 Check the...