10
11
ERROR
ISSUE
POSSIBLE CAUSE
Fridge does not work
Check if power is connected properly (check plugs are securely positioned and
positive and negative not reversed)
Check power switch in ON
Check if cooling unit ventilation is not blocked or restricted
Check the fuse at the supply or contact service to have the internal fuse (located
within the cooling unit) checked
Poor cooling performance
Check that the fridge is securely closed
Check if there is any damage to the fridge seals
Check if cooling unit ventilation is not blocked or restricted
Check the set temperature is adequate
Abnormal noise
Check if refrigerator is level
Check for vibration sources in surrounding objects
Check for loose items in the fridge
Water flow type noise is normal and not sign of any fault in the unit
Condensation
It is normal for some condensation to form on the refrigerator surface when
humidity is more than 75%
E1
Low Input Voltage
Power cord was inserted into the cigarette socket before car starts - wait for car
engine to start before plugging in
Battery protection level setting is too high - adjust the protection setting or
change to a power source with a higher output voltage
E2
Fan Fault
Contact service to have the fan replaced
E3
Compressor Start Fault
Shut down the fridge for 5 minutes and restart it - if it doesn’t fix the issue, follow
the procedures for E1 error
E4
Compressor Operation Fault Check the input voltage to the fridge and restart
E5
Overheat of Controller
Shut down the fridge for 5 minutes and check for cooling unit ventilation
restrictions or blockages
E6
NTC Open or Short Circuit
Contact service to have the NTC sensor checked
PART NO.
CFR1030XTM
GROSS CAPACITY:
35L
CLIMATIC CLASS:
T/ST/N/SN
RATED VOLTAGE - DC:
12V / 24V or 14.5V DC
RATED CURRENT - DC:
Up to 6A
PROTECTION LEVEL:
III
REFRIGERANT TYPE/AMOUNT:
R134a - 34g
FOAM VESICANT:
Cyclopentane
TEMPERATURE RANGE:
-20ºC to +10ºC
NET WEIGHT:
14KG
For further information or assistance please contact customer service on 1300 174 876