3
GB
Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be
turned off at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has
been completed and the unit is dry should the cabinet be turned
back on at the mains.
Suitable P.P.E (Personnel Protective Equipment) should be worn at all times.
Regular Maintenance:
>
As and when required remove all product and shelving (beware of cold and or sharp components) from
the unit. Clean exterior and interior surfaces with mild liquid detergent, following the directions on the
pack at all times. Rinse surfaces with a damp cloth containing clean water. Never use wire wool, scouring
pads/powders or high alkaline cleaning agents i.e bleaches, acids and chlorines as these may cause
damage.
>
Condenser Cleaning:
This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained
personnel.
Use a soft brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits left on
or through the condenser call your supplier to carry out a full service (this is normally chargeable). Failure
to maintain the condenser may invalidate the warranty of the condensing unit and cause premature
failure of the motor/compressor.
Do not use a wire brush to clean the condenser. Hoover or brush the air filter (where fitted).
>
All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a
warm damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
>
Removable shelves and their supports can be removed for cleaning. The shelves are dishwasher
safe; however the vertical supports should be cleaned with warm soapy water then rinsed and dried.
Troubleshooting
Alarms/Warnings -
During normal operation the display will show either the temperature or one of the following indicators:
Defrost In Progress
Condenser High Pressure Alarm
Controller In Standby
Room High Temperature Alarm
Condenser Clean Warning
Room Low Temperature Alarm
Door Open Alarm
Probe T1 Failure
Condenser High Temperature Alarm
Keypad Locked
Generic Alarm
(Some icons or switches are only visible during adjustment, when activated by parameters or through operation/
manual selection).