43
take effect the settings
I
: Control button: Control the test procedure
Stop: Stop Packet Generation
Start: Start Packet Generation
Pause: Pause the procedure
Resume: Resume to original procedure
Clear: Clear all counter for next test
P
: Time (sec): Duration of ongoing test
B
: Packet Length: packet length available for the test, from 64 to 1518 bytes, plus random length selections
D
: Transfer Rate (Mbps): The transmission throughput in Mbps. Please input value that fit the real network
environment; otherwise, packet loss would happen.
E
: Payload(0x): Contents in hexadecimal mode carried in Ethernet frame (packet). In the selections
Fixed value: 0000, FFFF, 5A5A, 55AA, 0F0F, 00FF. These values are repeated continually until the
end of the test
Byte increase: Byte of payload in frame is increasing
Random: The payload contents are generated randomly by the device.
BERT: Bit Error Rate Test is a testing method for digital communication circuits that uses
predetermined stress patterns comprising of a sequence of logical ones and zeros generated by a
pseudorandom binary sequence.
F
: Test Time (sec): Test duration of a single test.
H
: Destination MAC: Destination MAC address that this NuBAR-1000 will transmit packet for test.
I
: Source MAC: Source MAC address. It should be the MAC address of this NuBAR-1000
K
: VLAN: Tick to add VLAN tag in the packet (frame). When this option is selected, specify
L
: VID (VLAN ID) for the VLAN tag.
M
: IP: IP address in IP header of payload in Ethernet packet (frame)
N
: Destination IP: Destination IP address of the packet
O
: Source IP: Source IP address of the packet. It should be the IP address of this NuBAR-1000 itself.
Q
: Apply (button). Click it to take effect all configurations.
R
: Close (button). Click it to close this window.