12
Chapter 4
:
Instructions of operation, maintenance and
troubleshooting
4.1 Operation sequence:
4.1.1 Press power switch, then the indicator of the display screen is lit.
4.1.2 Press “memory release” key, then the display screen starts flashing.
4.1.3 Press “
↑
” or “
↓
” to input set number and time.
4.1.4 Then, press “Memory input” key to set program. After that, start packaging process.
4.1.5 If it’s necessary to stop or change program memory function during vacuum or sealing
process, press E-stop device (I) to achieve it. After that, release the E-stop device to
re-start the normal process.
4.1.6 single/auto mode switch: If you want to use single packaging mode, turn the single/auto
mode switch to single mode. Then, press start button for single packaging process. If
you want to use auto packaging mode, turn the single/auto mode switch to auto mode.
Then, press start button for auto process. If you want to stop packaging, press “stop
button” to stop it.
※
Attention: keep hands away from the packaging area during auto mode.
4.2 Maintenance:
4.2.1 Cleaning of vacuum chamber
4.2.1.1 If the working process is finished, use clean and wet cloth to wipe the vacuum
chamber and sealing set.