13
In the following section, the Photo Eye Safety System and
Wall Panel will be connected to the Opener. Please read and
understand the wiring instructions before connecting wires.
1.
Remove the pre
-
cut skin on the open end of wire from
accessories. Wires MUST NOT be frayed. Wires must be
connected as shown in Fig.1.
2. To connect a wire to an assigned terminal, use a small “flat
head” screwdriver to push in the orange tab on the Wire
Terminal as shown in Fig.2.
3.
Insert approximately 1/2” (13mm) of the wire into the
terminal while pushing in the tab as shown in Fig.2.
4.
Each accessory requires a pair of terminals. Each pair of
terminals MUST be connected with one white wire and one
striped wire (non
-
polarized) from the SAME accessory as
shown in Fig.2.
5.
Check for proper connection by gently pulling on the wire.
The wire should not come out of the terminal. NO exposed
part of the wire should be visible outside of the terminal.
6.
Use the insulated staples provided to secure the wires to
the wall and/or ceiling. Be careful not to damage the wires
while securing the staples.
!
WARNING
To prevent SERIOUS INJURY or DEATH from electrocution:
-
Power MUST NOT be connected until instructed.
-
NO exposed part of the wire should be visible outside of the terminal for proper connection.
Suggested placement of insulated staples
Wiring Instructions
Photo Eye Safety System
Fig. 2
Wire shown in actual size
1/2”
Wire Terminals
Fig. 1
2
3
Screwdriver or similar tool
1
Wire from accessories
Right
PUSH BUTTON
PHO TO EYE
* VERY IMPORTANT! *
Wrong
Right
Wrong