background image

 

 

15

 

 

Aligning the Photo Eye Safety System:

 

1.

 

When power is supplied, the Green photo eye (Emitter) will flash 

until it is aligned with the Red photo eye (Sensor).  The red 
photo eye will not light until it is aligned with the green eye.

 

2.

 

When the Photo Eye System is properly aligned the Green 

Photo Eye (Emitter) will emit a steady green light and the Red 
Photo Eye (Sensor) will emit a steady red light. 

 

3.

 

If either of the Photo Eye lights are unsteady, flash or dim, check 
for an obstruction and carefully adjust the position of the Photo 
Eyes until they give a steady green light and steady red light.  

 

 

Note:  The  path  of  the  invisible  light  beam  MUST  NOT  be 

obstructed.  No  part  of  the  garage  door  or  any  hardware 
should interfere or block either sensor.

 

Aligning the Photo Eye Safety System

 

For Permanent Wiring ONLY

 

DO NOT OPERATE OPENER AT THIS TIME.

 

To Connect Power

 

Plug  the  Opener  into  a  grounded  outlet  ONLY.  If  there  is  no 
grounded outlet present, call a qualified electrician to replace the 
outlet. Use of a surge protector is highly recommended page 4. 

 

Permanent Wiring (If Required by Local Code)

 

1.

 

Remove  the  enclosure  by  removing  the  6  screws  located 
on the sides and rear of the Opener.

 

2.

 

Cut the two  wire  connectors found inside  and  remove  the 
power cord.

 

3.

 

Group neutral (white) wires from power source with 2 white 
wires and 1 black wire from transformer inside the Opener. 
Connect them with a wire nut (not provided).

 

4.

 

Group  line  (black)  wires  from  power  source  with  another 
black  wire  from  transformer  and  a  brown  wire  inside  the 
Opener. Connect them with a wire nut (not provided).

 

5.

 

Secure  the  ground  (green  or  bare)  wire  from  the  power 
source with a grounding screw.

 

6.

 

Reinstall the enclosure.

 

7.

 

Turn on power supply.  If the wiring is properly connected, 
a  “click”  should  be  heard  and  the  light  will  illuminate  (if  a 
bulb is installed). If there is no response from the Opener, 
check power source and wiring.

 

WARNING

 

To prevent SERIOUS INJURY or DEATH from electrocution or fire:

 

-

 Power MUST be DISCONNECTED BEFORE proceeding with permanent wiring procedures.

 

-

 Garage Door Opener installation and wiring MUST be in compliance with all local electrical and building 

codes. Make sure the Opener is ALWAYS grounded.

 

-

 NEVER use an extension cord, 2

-

wire adapter or modify the power plug in any way to make it fit the outlet.

 

Conduit with wire

 

Black

 

(from transformer)

 

White

 

Neutral (White)

 

Wire nut

 

White

 

Line (Black )

 

Ground (Green/Yellow)

 

Ordinary Power Connection

 

Invisible Light Beam

 

WARNING

 

To prevent SERIOUS INJURY or DEATH from a closing garage door:

 

-

 The Photo Eye Safety System MUST be installed BEFORE connecting power.

 

-

 The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener.

 

Connecting Power

 

Black (from transformer)

 

Brown

 

Ground Screw (Green)

 

The emitter 

generates the 

invisible light 

beam

 

The sensor 

receives the 

invisible light 

beam

 

Steady Red & 

Green light

 

NOTICE: The opener will not close until the photo eyes are installed.  Photo eyes are required by federal law to 

be installed on all openers. 

 

Summary of Contents for Quiet-Drive 425-1656

Page 1: ...__ Date Installed __ __ __ __ __ __ __ __ GDO Manual Revised 4 12 For serial 5555555 and later For Use With Residential Sectional Garage Doors Only GARAGE DOOR OPENER MODEL 425 1656 HANDLES DOORS 18 F...

Page 2: ...ye Safety System 14 Connecting Power 15 Connecting Wall Panel 19 Adjustment Aligning the Photo Eye Safety System 15 Travel Limit Adjustment I UP Limit 16 Travel Limit Adjustment II DOWN Limit 17 Auto...

Page 3: ...ulley Hitch Pin Locking Clevis Pins x 4 Lag Screw 12 x 1 Photo Eye System Lag Screw 5 16 x 1 1 2 Header Bracket Mounting Opener Bolt 5 16 x 1 Drywall Anchor x 4 x 30 5 16 Flange Nut x 4 x 4 x 4 x 4 x...

Page 4: ...sion Call a qualified garage door service technician if your door binds sticks or is unbalanced WARNING To prevent SERIOUS INJURY or DEATH Before beginning installation of the Opener please complete t...

Page 5: ...llet Only use a soft rubber mallet to tap on the end of the rails as other tools may damage your rail Rail Header Segment Rail Middle Segments tapered x 3 Rail End Segment tapered with Trolley Stop Bo...

Page 6: ...Fig 2 1 Place the belt beside the rail as shown 2 Insert a temporary screwdriver into the hole approximately 10 1 4 from the end of the Rail Header Segment Slide the trolley against this screw driver...

Page 7: ...le Keep hands and fingers away from joints and possible sharp edges Belt Connector Tighten until Tighten nut Flange Nut 1 4 Installing the Belt 1 4 6mm Base of Rail Mid point of rail assembly Belt Top...

Page 8: ...ket on the vertical mark no more than 6 15cm from the header wall Mark and drill holes to fasten the Header Bracket securely to a structural support Fig 1 Ceiling Header Bracket Header Wall 2 5cm clea...

Page 9: ...nt bracket with this option skip this step and proceed with the next step Mounting Opener to Ceiling 1 Position the Door Bracket on the centerline of the door approximately 2 4 5 10cm below the top ed...

Page 10: ...e Hanging Brackets to the structural supports using 5 16 x1 2 Lag Screws provided 7 Secure the Opener to the Hanging Brackets and secure each side with a 5 16 x 1 Bolt and Flange Nut provided 8 Move t...

Page 11: ...damage to the garage door opener Clevis Pin 5 16 x 1 Hitch Pin Bolt 5 16 18x1 Flange Nut Curved Door Arm Straight Door Arm 1 1 2 2 Fig 1 3 Attaching Door Arms Min 8 20cm To Connect Door Arm Follow th...

Page 12: ...HANDLE to release door from Open er When Emergency Release is in the released position the door can be operated manually To reconnect flip the lever on the Trolley towards Opener back to Connect posit...

Page 13: ...wire and one striped wire non polarized from the SAME accessory as shown in Fig 2 5 Check for proper connection by gently pulling on the wire The wire should not come out of the terminal NO exposed p...

Page 14: ...garage door as shown in Fig 2 2 If attaching to concrete secure the photo eyes using concrete anchors and bolts not provided 3 If necessary align the Photo Eyes by loosening the wing nut This step may...

Page 15: ...rovided 4 Group line black wires from power source with another black wire from transformer and a brown wire inside the Opener Connect them with a wire nut not provided 5 Secure the ground green or ba...

Page 16: ...before proceeding with adjustments I Setting Travel UP Limit 1 Press and Release LIMIT button ONCE to enter Travel Limit Adjustment UP indicator green will turn on NOTE Once you have pressed and relea...

Page 17: ...s I Setting Travel DOWN Limit 1 Press and Release LIMIT button TWICE to enter Travel Limit Adjustment DOWN indicator red will turn on NOTE Once you have pressed and released the Limit button twice the...

Page 18: ...s OK x1 UP DOWN FORCE LIMIT UP DOWN 1 2 3 Auto Force Adjustment NOTICE This opener will not work until you set the travel limits and the auto force adjustment You must follow all steps on pages 16 17...

Page 19: ...installed out of the reach of children and free from the moving parts of the door and hardware 2 Fasten it to a solid surface with 1 screws If attaching to drywall or other hollow surface drill 3 16 h...

Page 20: ...and the opener is ready to use If the door fails to reverse upon contact with obstruction adjust the Opener as follows The close travel maybe inadequate reset down limit and force See Travel Limit Ad...

Page 21: ...g the above procedures If more than 20 Transmitters are stored the first stored Transmitter will be replaced i e the 21st Transmitter replaces the 1st stored Transmitter Removing ALL Transmitters To r...

Page 22: ...personal code and press ENTER to transmit code and within 20 seconds ENTER button can be used to stop or reverse the door If the code is entered incorrectly correction can be made by pressing ENTER to...

Page 23: ...ur door is balanced and in good working condition Operating the Opener Emergency Release Knob Photo Eye Safety System Invisible Light Beam Actual Operating Scenario Wall Panel Controls Operation Wall...

Page 24: ...verse Door is opening Door will stop Door is stopped as intended in partially open position Close Door is obstructed while closing Door will reverse and Beep x 20 Door is obstructed while opening Door...

Page 25: ...y hits the Trolley Stop Bolt in open travel 1 Disconnect the Trolley by using the Emergency Release 2 Close the door manually 3 Relieve the belt tension by loosening both the belt connector and the Fl...

Page 26: ...o Eye Safety System Emitter Sensor with Brackets 2 24113 XPRO 3 Button Hand held Transmitter 3 24939 12V alkaline transmitter battery 4 24165 Wall Panel 5 24140 Keyless Entry 6 24050 M Owner s manual...

Page 27: ...sis 2 24948 Transformer 3 24930 Logic Board 4 24932 Position Encoder 5 24947 DC Motor 6 24983 Cover plate Front 7 24984 Cover plate Back 8 24980 Opener Cover 9 N A Lamp Plate 10 24905 Lamp Dome 11 249...

Page 28: ...IFICATION OR DISSASSEMBLY OF THIS PRODUCT VOIDS THIS LIMITED WARRANTY DECKODISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE...

Reviews: