background image

Xtreme Power Conversion Corporation

T90 User’s Manual

Page 3

Uninterruptible Power Supply

Button Operation...........................................................................................................................24

Control Panel Functions.................................................................................................................25

Troubleshooting.............................................................................................................................28

Maintenance..............................................................................................29

Replacing Batteries........................................................................................................................29

Technical Specifications..............................................................................31
Terminal Block............................................................................................32
Obtaining Service.......................................................................................33
Xtreme Power Conversion Limited Warranty...............................................34
Xtreme Power Conversion Load Protection Policy.......................................35

Summary of Contents for 700VA

Page 1: ...T90 Online UPS 700VA 1000VA 1500VA 2000VA 3000VA Models User Installation Manual www xpcc com 2014 Xtreme Power Conversion Corporation All rights reserved Rev 9 15 14...

Page 2: ...ction 9 Free Run Mode 9 Diagnostic Tests 9 SystemConfiguration 9 SystemConfiguration 10 Storage 11 Installation 11 Environment 11 RearPanelViews 15 Rear Panel Views 16 Connection To Mains And Loads 20...

Page 3: ...e Power Supply ButtonOperation 24 ControlPanelFunctions 25 Troubleshooting 28 Maintenance 29 Replacing Batteries 29 Technical Specifications 31 TerminalBlock 32 Obtaining Service 33 Xtreme Power Conve...

Page 4: ...rovides important information that should be followed during installation and main tenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and per formance...

Page 5: ...nt meets all requirements of the Canadian Interference Causing Equip ment Regulations ICES 003 Cet appareil numerique de la classe B respecte toutes les exigencies du Reglement sur le materiel brouill...

Page 6: ...r installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin...

Page 7: ...der to reduce the risk of electric shock It is best to disconnect the device using the power supply cord Ensure that the equipment is placed in a position near the outlet where easily accessible Excep...

Page 8: ...ts and radio transmissions to motors air conditioners and vending machines among others So protection of sensitive electrical equipment is vital to protect against power outages low or high voltage sl...

Page 9: ...er to chapter 7 2 if you want bypass available while running in free run mode Diagnostic Tests When you start the UPS a diagnostic test is automatically executed that checks electronics battery and re...

Page 10: ...airtight a safety hazard situation ex ists in which no electrical equipment should be operated The instructions in this manual explain how to install the UPS safely Not acknowledging such electrical...

Page 11: ...wise the safety of installation personnel cannot be guaranteed and the unit may malfunction Ensure that you remember the following when locating the UPS system and battery options Avoid extremes of te...

Page 12: ...ninterruptible Power Supply 1 19 Rack installation Mount the 2U rack mount in a 19 inch EIA 310 C standard rack 2 23 Rack installation Change the position of the two mounting brackets to mount the 2U...

Page 13: ...unting brackets from the front to the side and attach the brackets by screws Then let the UPS stand with the vertical direction as the below pictures shown 4 Wall installation Move the mounting bracke...

Page 14: ...Xtreme Power Conversion Corporation T90 User s Manual Page 14 Uninterruptible Power Supply 5 Installation with rear Bracket We can use bracket to support the rear side of UPS or battery cabinet...

Page 15: ...Xtreme Power Conversion Corporation T90 User s Manual Page 15 Uninterruptible Power Supply Rear Panel Views 700 1 5kVA Rear Panel...

Page 16: ...Xtreme Power Conversion Corporation T90 User s Manual Page 16 Uninterruptible Power Supply Rear Panel Views 2kVA 3kVA Rear Panel...

Page 17: ...Xtreme Power Conversion Corporation T90 User s Manual Page 17 Uninterruptible Power Supply RM 1U 700 1KVA Rear Panel...

Page 18: ...Xtreme Power Conversion Corporation T90 User s Manual Page 18 Uninterruptible Power Supply RM 2U 700 1K 1 5KVA Rear Panel...

Page 19: ...Xtreme Power Conversion Corporation T90 User s Manual Page 19 Uninterruptible Power Supply RM 2U 700 1K 1 5KVA Rear Panel...

Page 20: ...a grounded outlet The batteries will automatically charge when connected to the mains Please realize that although you may start using the UPS immediately maximum back up time will still not be availa...

Page 21: ...V FOR LV series 208 220 230 240 Vac 230V FOR HV series Input Bypass Voltage 10 10 15 15 20 10 15 Input Frequency 2 5 7 5 HE Mode Setting On Off Off Free Run Mode On Off On Bypass Enable Disable at fre...

Page 22: ...r will have more information about these option cards Connecting the UPS to a Computer The communication device for the UPS and PC comes as a complete package with power management software Only the c...

Page 23: ...The UPS will have to be manually restarted in order to regain power to the outlets Network Transient Protector The network transient protector located on the back panel has both IN and OUT jacks and h...

Page 24: ...e UPS will shut down The LCD will display UPS OFF for a few seconds In emergency situations the EPO located on the back of the unit should be used Button Operation Please note the three operating butt...

Page 25: ...s are all indicated on the LCD screen Control panel Normal display The UPS status is shown in normal display mode From here you have a choice to go to UPS meters display and the Setting display by pus...

Page 26: ...tting O P V Setting Select Nominal Voltage 208 220 230 240V 230V 100 110 115 127V 120V Input Frequency I P F Setting Select input frequency range when UPS goes into free run mode 2 5 7 5 Input Bypass...

Page 27: ...Note You should turn UPS off and keep the AC power before you use Generator function even you want to select Generator OFF to back to normal mode Interpreting UPS Messages Troubleshooting procedures d...

Page 28: ...ble power returns On Battery Once every 5 seconds The unit is operating on Battery Power Save your data and perform a con trolled shutdown Charger Failure Constant beep Charger has failed Phone the lo...

Page 29: ...ies may be replaced without having to turn the UPS off or disconnecting the load due to the hot swap pable battery feature WARNING Batteries may cause electrical shock or burn from high short circuit...

Page 30: ...moved by pushing where the arrows indicate in the pictures above Next unscrew the screws and remove the metal battery cover 2 Remove the battery cartridge from the UPS The voltage in all models will b...

Page 31: ...31 lbs 38 lbs 39 lbs 73 lbs 78 lbs 39 lbs Line cord 5 15P 5 20P L5 30P IEC C14 inlet Receptacles 6 NEMA 5 15R 12 NEMA 5 20R 10 NEMA 5 15R 4 IEC C13 1 L5 30R LCD display Input output voltage input out...

Page 32: ...10 AWG 90 C copper wire and 20 lb in torque force when connecting For 3000VA Please refer to the terminal block connection diagram to connect and use No 12 AWG 90 C copper wire and 8 lb in torque for...

Page 33: ...sk you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorizati...

Page 34: ...ipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an...

Page 35: ...C Limited Warranty against certain losses caused by a Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provi...

Page 36: ...Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for dam...

Page 37: ...payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves the rig...

Reviews: