background image

Xtreme Power Conversion Corporation

A60 User’s Manual

Page 2

Uninterruptible Power Supply

Table of Contents

Installation and Operation............................................................................3

LCD Display..................................................................................................3

Product Overview........................................................................................

 

3

LED Indicators..............................................................................................4

Safety Precautions.......................................................................................5

Troubleshooting...........................................................................................6

Specifications...............................................................................................7

Obtaining Service.........................................................................................8

Xtreme Power Conversion Limited Warranty................................................9

Summary of Contents for A60-550

Page 1: ...A60 Standby UPS 550VA 750VA Models User Installation Manual www xpcc com 2020 Xtreme Power Conversion Corporation All rights reserved Rev 8 24 20 ...

Page 2: ...al Page 2 Uninterruptible Power Supply Table of Contents InstallationandOperation 3 LCD Display 3 Product Overview 3 LED Indicators 4 Safety Precautions 5 Troubleshooting 6 Specifications 7 Obtaining Service 8 Xtreme Power Conversion Limited Warranty 9 ...

Page 3: ...ter ing line conditioning and surge protection Battery power is automatically provided in case of power failure Surge Protected Outlets 4 or 5 Connect a printer fax machine or scanner to the Surge protected outlets These outlets do not provide power during power failure CAUTION NEVER connect a laser printer or scanner to the battery backup sockets of UPS The equipment may draw significantly power ...

Page 4: ...d on it will enter this mode for 4 seconds AC Mode LCD information will be displayed in the following order when LCD is touched 1 Output voltage 2 Input voltage 3 Load level 4 Battery capacity Overload in AC mode icon will flash When overload occurs alarm will beep every 0 5 second Battery Mode When battery level is low icon will flash Alarm will beep every 10 seconds and LCD information will be d...

Page 5: ...installed by the supplier is operator installable and may be operated by laymen The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Connection to any other type of receptacle other than ...

Page 6: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Do not dispose of batteries in a fire as they may explode Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number and type of ...

Page 7: ...12V 4 5AH 1 12V 5AH Recharge 8 hours to 90 capacity PHYSICAL UPS dimensions W x D x H 6 2 x 12 x 3 7 in UPS weight 5 7 lbs 6 4 lbs Line cord 6 ft 5 15P Receptacles 10 NEMA 5 15R receptacles 5 battery back up 5 surge only USB charging port N A 2 USB A type 5V 2 4A ENVIRONMENT Operating temperature 32 104 F 0 40 C Humidity 0 90 Altitude 11 500 ft above sea level INDICATORS Display 3 LED s Touch LCD ...

Page 8: ...sk you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask the ...

Page 9: ...uipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manual ...

Reviews: