P91c-1000 User’s Manual

Page 8

Uninterruptible Power Supply

Operations

Button operation

1K View:

Button 

Function 

ON/OFF Button 

•  Turn on the UPS: Press and hold button for at least 2 seconds to turn on 

the UPS. 

•  Turn off the UPS: Press and hold this button at least 2 seconds to turn off 

the UPS. UPS will be in standby mode when utility power is normal or 

transfer to bypass mode if bypass mode is enabled via software.

1KL View:

 

Button

Function

On/Mute Button

•  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds 

to turn on the UPS.

•  Mute the alarm: When the UPS is on battery mode, press and hold this 

button for at least 5 seconds to disable or enable the alarm system. But 

it’s not applied to the situations when warnings or errors occur. 

Off/Enter Button

•  Turn off the UPS: Press and hold this button at least 2 seconds to turn 

off the UPS in battery mode. UPS will be in standby mode under power 

normal or transfer to Bypass mode if the Bypass enable setting by press

-

ing this button.

LED indicators       On/Off button

Summary of Contents for P91c-1000

Page 1: ...P91c 1000 UPS 1000VA Model User Installation Manual www xpcc com 2021 Xtreme Power Conversion Corporation All rights reserved Rev 5 6 21 ...

Page 2: ...tion 3 Preparation 3 Installation 3 Operation 3 Maintenance serviceandfaults 4 Installationandsetup 5 Rear panel view 5 Setup the UPS 6 Operations 8 Button operation 8 LEDpanel 9 Troubleshooting 10 StorageandMaintenace 11 Specifications 12 ObtainingService 13 Xtreme Power Conversion Limited Warranty 14 Xtreme Power Conversion Load Protection Policy 15 ...

Page 3: ...tion holes in the UPS housing Installation Setup Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output receptacles Place cords in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output receptacles The UPS can be operated by any individuals with no previous experience Connect t...

Page 4: ...ery When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same type and amperage in order to avoid fire hazards Do not dismantle the UPS system...

Page 5: ...ect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use Rear panel view 1KL 1 AC input power cord 2 Output receptacle connect to mission critical loads 3 Programmable outlets connect to non critical loads 4 USB serial communication port 5 ROO RPO function connector 6 Intelligent slot ...

Page 6: ...d status monitoring connect the communication cable one end to the USB port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for Relay and Modbus card When installing with SNMP card in the UPS it will provide advanced communication and ...

Page 7: ...e from the internet 1 Go to the website http www power software download com 2 Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock Contact open UPS shuts down Contact closed...

Page 8: ...s enabled via software 1KL View Button Function On Mute Button Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS Mute the alarm When the UPS is on battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur Off Enter Button Turn off the UPS Press and h...

Page 9: ... LED7 0 25 load level Green On Battery Mode LED2 Yellow Flashing LED4 to LED7 indicate battery capacity during battery mode LED4 battery voltage 26V LED5 battery voltage 24 5V LED6 battery voltage 23V LED7 battery voltage 21V Green On Low battery LED7 Green On LED3 Red On Battery replacement LED3 Red Flashing Fault LED3 Red On On off status of out put receptacles LED 8 indicating on off status of ...

Page 10: ...ery second The internal battery connection is wrong Please re connect battery wires with correct polarity The alarm is sounding twice every second and red LED is flashing UPS is overloaded Remove excess loads from UPS output After repetitive overloads the UPS is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UP...

Page 11: ...ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Model Storage Temperature Recharge Frequency Charging Duration P91c 1000 25 C 50 C Every 3 months 1 2 hours 50 C ...

Page 12: ...id Battery quantity size 4 6V 290W Typical recharge 6 hours to 90 PHYSICAL Dimensions W x D x H 17 2 x 18 8 x 1 7 in Weight 28 lbs Line cord 5 ft 5 15P Receptacles 3 NEMA 5 15R ENVIRONMENT Operating temperature 32 104 F 0 40 C Altitude 11 500 ft above sea level APPROVALS UL cUL RoHS WARRANTY 3 years electronics 3 years battery warranty USA and Canada COMMUNICATIONS INTERFACE USB EPO intelligent sl...

Page 13: ...ll ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mate rial Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available ask ...

Page 14: ... equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifi cations or c the equipment has been used or stored in a manner contrary to the equipment s operating manu...

Page 15: ... from insurance other warranties extended warranties a legal liability claim or from other sources or persons for the damaged Connected Equipment 5 Purchaser means the person or entity that originally purchased the Product from an authorized reseller or distributor of XPC Products The Purchaser of this Product is protected for the term of the XPC Limited Warranty against certain losses caused by a...

Page 16: ...Load Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for damage due to telephone line Local Area Network or CATV transients which is covered only if the Product offers such protection 3 DAMAGE CAUSED BY FAILURE TO PROVIDE A SUITABLE INSTALLATION ENVIRONMEN...

Page 17: ...sue payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves the right to require the Purchaser to transfer title and deliver the Connected Equipment to XPC if it chooses to reimburse the Purchaser for the fair market value of the Connected Equipment XPCs maximum l...