background image

Xtreme Cooling

Portable Air Conditioners

Models: XC-14A, XC-22A, XC-30A

User’s & Installation Manual

Xtreme Power Conversion® (XPC) Corporation

Summary of Contents for XC-14A

Page 1: ...Xtreme Cooling Portable Air Conditioners Models XC 14A XC 22A XC 30A User s Installation Manual Xtreme Power Conversion XPC Corporation ...

Page 2: ...ON 11 Control Panel MAINTENANCE 12 Filter Cleaning Spring Replacement TROUBLESHOOTING 15 SPECIFICATIONS 18 SHIPPING LIST 19 OBTAINING SERVICE 20 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY 21 OPTIONS 23 Alarm Codes Troubleshooting Chart Ambient Air Adaptor Cooling Hose Assembly Temperature Sensor Line Remote Control Pump Kit XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners...

Page 3: ...as it provides important information that should be followed during installation and maintenance of the Portable Air Conditioner allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the unit please refer to the Troubleshooting section in this manual to correct t...

Page 4: ...t s inlet and or outlet grilles 8 DO NOT use the unit in areas where it will be exposed to rain or water 9 NEVER unplug the unit while it is operating 10 DO NOT place any foreign objects on the unit 11 DO NOT operate the unit with wet or damp hands 12 DO NOT allow chemical substances to come in contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such a...

Page 5: ...avoid overheating If the power cord becomes damaged a qualified service agent qualified electrician or similarly qualified person must replace it in order to avoid a hazard or shock 19 The filters must be used with the product at all times When the filters are removed for cleaning always ensure that the unit has been turned off and unplugged from the electrical outlet 20 Regularly clean the filters to ma...

Page 6: ... fatal XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Xtreme Power Conversion XPC Corporation Page 6 PRODUCT DESCRIPTION Xtreme Cooling Portable Air Conditioners feature spot cooling for large areas where cooling of the entire area is not practical or possible A dedicated spot cooling thermostat controls the unit in this application These air conditioners can also be used in smaller ...

Page 7: ...igure 2 Rear and Left Side View Display Control board Top fan wire grille Evaporator filter Guide bar for condensate water tank Condensate water tank Water level is sensed and the unit operation is stopped when tank is full An alarm will be displayed Empty the tank and replace to resume operation Side handles Rubber stoppers Condenser filter Power cord holder Casters Electrical access panel ...

Page 8: ... 3 3 Use screws to install the Power Cord Holder to the rear of the unit screws inside the accessory box 1 Remove the Rubber Stoppers from the accessory box 2 Place the Rubber Stoppers on the rear of the unit as shown in Figure 4 3 Use screws to install the Rubber Stoppers to the rear of the unit screws inside the accessory box Power Cord Holder Rubber Stoppers Figure 3 Power Cord Holder attachmen...

Page 9: ...se s to the front of the unit screws inside the accessory box WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION INSTALLATION GUIDE DO NOT use the unit in explosive environments or in areas where flammable gas leakage may occur WARNING DO NOT use the unit in areas where it will be exposed to rain or water WARNING DO NOT install the unit on uneven or sloping surface The unit may roll or topple over...

Page 10: ...amage or excess play is found contact a qualified repair technician or a qualified electrician to perform replacement of repair of the power cord plug or prongs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material The unit is equipped with an approved NEMA plug configuration XC 14A 5 15P XC 22A 6 15P XC 30A 6 20P The appropriate outlet must be used for each plug t...

Page 11: ...s pressed during operation unit stops OPERATION 1 2 5 3 4 6 8 7 3 SPOT COOL BUTTON Activates compressor and begins producing cool air 5 seconds after button is pressed Regulates temperature based on outlet cool air temperature 4 ROOM COOL BUTTON Activates compressor and produces cool air 5 seconds after button is pressed Regulates temperature based on inlet ambient air temperature 2 BLOWER BUTTON ...

Page 12: ...ARM light is activated blinking longer than 3 minutes 7 CURRENT TEMP Room cool mode displays current room temperature in display in Fahrenheit SPOT COOL Mode displays outlet cool air temperature during normal operations In order to change F to C press SPOT COOL and ROOM COOL buttons together for 2 seconds C will blink 2 times and the figure will change to C ALARM codes blink and are displayed when ...

Page 13: ...talling 1 To clean the evaporator filter pull the front filter guard forward from the top until the guard is open in an angled position and resting on the supporting cables 2 Slide the filter up and use a vacuum cleaner to remove the dust from the filter 3 If the filter is heavily covered with dust and dirt warm water and mild soap or neutral detergent may be used to wash the filter Do not use any other...

Page 14: ... clean the condenser filter lift up on the rear filter from the middle bar slightly and then angle the filter outwards from the bottom and remove 7 Use the same cleaning procedure as in steps 3 5 above 8 To replace the condenser filter place the top of the filter in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of the filter into the guide and let t...

Page 15: ...s displayed on the control panel The compressor and condenser fan motor will stop operating The evaporator fan will continue to run for 3 minutes If the fault is rectified within 3 minutes the unit will resume operation If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation TROUBLESHOOTING ...

Page 16: ...ate tank is full Drain pump defective or improper hose connection including kink or blockage Ambient temperature is too high Unstable voltage supply Defective compressor Do not use the air conditioner if ambient temperature is lower than 18 C 64 F Contact a qualified service agent Clean air filter Ensure exhaust duct is not blocked kinked Do not use the air conditioner if ambient temperature is high...

Page 17: ...leaned Compressor restart in 2 minutes after turning off to protect the compressor The ambient air temperature may be too high No cause Spring is possibly broken Remove blockage from drain hose Remove any object stuck underneath of the black panel under the water tank Reset the circuit breaker and restart the unit Connect the power cord Clean air filter Verify that 2 minutes have passed since the co...

Page 18: ...0 20 3 1 2 4 1142 0 091 0 089 0 24 0 20 0 13 0 11 0 08 0 26 0 24 Aluminum Vinyl chloride 6 20P 12 10 R410A 39 9 64 113 16 30 22 0 x 24 4 x 50 4 Power Supply Size W x D x H Weight Current Consumption Circuit Breaker Size Power Consumption Compressor Input NEMA Plug Power Cord Gauge Power Cord Length Operating Conditions Hot Air Duct Diameter Maximum Duct Length Refrigerant Air Flow High Low Evapora...

Page 19: ...tion XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 19 1 PORTABLE COOLING UNIT 1 User s and Installation Manual 1 POWER CORD HOLDER 4 RUBBER STOPPERS DISCHARGE SUPPLY AIR DUCTS 1 XC 14A 2 XC 22A 3 XC 30A SHIPPING LIST ...

Page 20: ...of the model information about your Xtreme Cooling unit e Any information on the failure including LED s that may or may not be illuminated f A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will is...

Page 21: ... of one year for Xtreme Cooling unit from the date of purchase For equipment sites within the United States and Canada this warranty covers repair or replacement at the sole discretion of XPC Corporation The customer is responsible for the costs of shipping the defective product to XPC Corporation XPC Corporation will pay for ground shipment of the repaired or replacement product This warranty app...

Page 22: ...ent is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances but it is used at the recipient s sole risk EXCEPT AS STATED ABOVE XPC Corporation DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS STATED ABOVE IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT...

Page 23: ...er Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 23 Ambient Air Adaptor Cooling Hose Assembly Exhaust Flanges Temperature Sensor Line Remote Control Pump Kit OPTIONS ...

Page 24: ...Xtreme Power Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 24 ...

Reviews: