background image

Turn

 

UPS

 

ON

 

/

 

OFF

 

To

 

turn

 

the

 

UPS

 

unit

 

on,

 

press

 

the

 

Power

 

switch

 

on

 

the

 

front

 

of

 

the

 

UPS.

 

To

 

turn

 

the

 

UPS

 

unit

 

off,

 

press

 

the

 

Power

 

switch

 

on

 

the

 

front

 

of

 

the

 

unit

 

again.

 

Connecting

 

Local

 

Monitoring

 

Software

 

(optional)

 

If

 

it

 

is

 

desired

 

to

 

use

 

the

 

Local

 

Monitoring

 

Software,

 

and

 

if

 

your

 

UPS

 

is

 

equipped

 

with

 

USB

 

communications,

 

connect

 

a

 

USB

 

cable

 

from

 

your

 

computer

 

to

 

the

 

UPS,

 

and

 

install

 

the

 

software

 

from

 

the

 

CD.

 

Indicators

 

&

 

Alarm

 

Conditions

 

 

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

                                  

Page

 

5

 

XST

 

USERS

 

MANUAL

 

Condition

 

Visual

 

Indicator

 

Alarm

 

AC

 

mode

 

Blue

 

LED

 

illuminated

 

No

 

Audible

 

Alarm

 

Battery

 

mode

 

Blue

 

LED

 

flashes

 

every

 

10

 

seconds

 

Audible

 

Alarm

 

sounds

 

every

 

10

 

seconds

 

Low

 

battery

 

mode

 

Blue

 

LED

 

flashes

 

every

 

1

 

second

 

and

 

Red

 

LED

 

is

 

illuminated

 

Audible

 

Alarm

 

sounds

 

every

 

1

 

second

 

Fault

 

Red

 

LED

 

is

 

illuminated

 

Audible

 

Alarm

 

is

 

continuous

 

Alarm

 

for

 

over

 

temperature

 

protection

 

Red

 

LED

 

flashes

 

every

 

0.5

 

seconds

 

No

 

Audible

 

Alarm

 

XTREME

 

POWER

 

CONVERSION

®

 

LOAD

 

PROTECTION

 

POLICY

 

For

 

Standard

 

EPC

 

120,

 

208

 

and

 

240

 

Volt

 

Products

 

used

 

in

 

the

 

United

 

States

 

and

 

Canada

 

THIS

 

POLICY

 

IS

 

NOT

 

A

 

WARRANTY.

 

REFER

 

TO

 

THE

 

XPC

 

CORPORATION,

 

INC.

 

LIMITED

 

WARRANTY

 

FOR

 

INFORMATION

 

CONCERNING

 

THE

 

WARRANTY

 

FOR

 

YOUR

 

XPC

 

PRODUCT.

 

THE

 

LIMITATIONS

 

AND

 

CONDITIONS

 

CONTAINED

 

IN

 

THIS

 

POLICY

 

DO

 

NOT

 

AFFECT

 

THE

 

TERMS

 

OF

 

THE

 

XPC

 

LIMITED

 

WARRANTY.

 

Definitions:

 

1.

 

“Product”

 

means

 

an

 

XPC

 

Standard

 

EPC

 

120,

 

208,

 

or

 

240

 

Volt

 

power

 

protection

 

device

 

that

 

is

 

used

 

in

 

the

 

United

 

States

 

and

 

Canada.

  

This

 

policy

 

does

 

not

 

include

 

custom

 

manufactured

 

products.

 

2.

 

“Power

 

Disturbance”

 

means

 

an

 

AC

 

power

 

line

 

transient

 

(telephone

 

line,

 

local

 

Area

 

Network

 

or

 

CATV

 

transients,

 

if

 

applicable),

 

spike

 

or

 

surge.

 

3.

 

“Fair

 

Market

 

Value”

 

of

 

damaged

 

Connected

 

Equipment

 

as

 

determined

 

by

 

XPC

 

shall

 

be

 

the

 

lower

 

of

 

(a)

 

the

 

average

 

price

 

the

 

same

 

or

 

similar

 

items

 

are

 

being

 

sold

 

for

 

on

 

eBay,

 

(b)

 

the

 

price

 

list

 

of

 

Orion

 

Blue

 

Book

 

(or

 

if

 

such

 

price

 

list

 

is

 

no

 

longer

 

published,

 

a

 

published

 

or

 

announced

 

price

 

list

 

reasonably

 

selected

 

by

 

XPC),

 

(c)

 

the

 

lowest

 

price

 

the

 

same

 

or

 

similar

 

items

 

can

 

be

 

purchased

 

for

 

in

 

the

 

United

 

States

 

or

 

(d)

 

the

 

total

 

amount

 

of

 

all

 

payment(s)

 

you

 

have

 

or

 

are

 

entitled

 

to

 

receive

 

from

 

insurance,

 

other

 

warranties,

 

extended

 

warranties,

 

a

 

legal

 

liability

 

claim

 

or

 

from

 

other

 

sources

 

or

 

persons

 

for

 

the

 

damaged

 

Connected

 

Equipment.

 

4.

 

“Initial

 

Purchaser,”

 

“Purchaser”

 

or

 

“You”

 

means

 

the

 

person

 

or

 

entity

 

that

 

originally

 

purchased

 

the

 

Product

 

from

 

an

 

authorized

 

reseller

 

or

 

distributor

 

of

 

XPC

 

Products.

    

The

 

Initial

 

Purchaser

 

of

 

this

 

Product

 

is

 

protected,

 

for

 

the

 

term

 

of

 

the

 

XPC

 

Limited

 

Warranty,

 

against

 

certain

 

losses

 

caused

 

by

 

a

 

Power

 

Disturbance

 

for

 

properly

 

connected

 

electronic

 

equipment

 

(referred

 

to

 

as

 

the

 

"Connected

 

Equipment")

 

subject

 

to

 

certain

 

terms

 

and

 

conditions

 

provided

 

below.

   

This

 

policy

 

applies

 

only

 

to

 

the

 

original

 

purchaser

 

of

 

the

 

Product.

   

If

 

the

 

Product

 

is

 

transferred

 

or

 

sold

 

to

 

another

 

person

 

or

 

entity,

 

this

 

policy

 

is

 

void.

   

Load

 

Protection

 

Policy

 

Dollar

 

and

 

Period

 

Limits

 

For

 

purchasers

 

that

 

meet

 

the

 

qualifications

 

and

 

conditions

 

set

 

forth

 

in

 

this

 

policy,

 

XPC

 

will

 

provide

 

reimbursement

 

(cost

 

of

 

repair

 

or

 

fair

 

market

 

value

 

as

 

determined

 

by

 

XPC)

 

during

 

the

 

period

 

limits

 

and

 

up

 

to

 

the

 

dollar

 

limits

 

stated

 

as

 

follows:

 

 

 
This Load Protection Policy is not deemed "first dollar" coverage. XPC’s obligation is reduced 
by any amounts that the Initial Purchaser is entitled to recover, from other sources regarding 
the Connected Equipment, including, but not limited to, insurance, other warranty, extended 
warranty, or legal liability, regardless of whether or not the Initial Purchaser makes a claim for 
recovery.  

Product

 

Dollar limit

 

Period of Coverage

 

XST, XVT

 

25,000

 

 

Term of XPC Limited Warranty

 

 NXRT-XPRT- 6 kva

 

50,000

 

 Term of XPC Limited Warranty

 

NXRT-XPRT-10 kva

 

50,000

 

 Term of XPC Limited Warranty

 

XST

 

USERS

 

MANUAL

 

Page

 

12

 

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

 

Summary of Contents for XST?400

Page 1: ...Xtreme Standby Tower Series XST 400 600 800 User Manual Xtreme Power Conversion XPC Corporation XST USERS MANUAL Page 16 Xtreme Power Conversion XPC Corporation ...

Page 2: ... a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Product Overview The XST Series UPS provides comprehensive protection in a small and economical package This UPS is compact offering greater power The XST has been...

Page 3: ...ice b If the Product shows evidence of damage from a Power Disturbance XPC will request that all Connected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to you for either t...

Page 4: ... land line or PBX telephone equipment line that is properly installed and connected to an RJ11 port on the Product or by a Power Disturbance on a standard Local Area Network connection that is properly installed and connected to an RJ45 port on the Product and d is directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturb...

Page 5: ...d for on eBay b the price list of Orion Blue Book or if such price list is no longer published a published or announced price list reasonably selected by XPC c the lowest price the same or similar items can be purchased for in the United States or d the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or f...

Page 6: ...ration will pay for ground shipment of the repaired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the customer has requested...

Page 7: ...ing the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the model information about your UPS e Any information on the failure including LED s that may or may not be illuminated f A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if...

Page 8: ...y defect Replace the battery with the same type of battery The AC input is normal but the blue LED is flashing Power cord is loose Reconnect the input power cord properly When power fails backup time is shorter than expected Specifications Xtreme Power Conversion XPC Corporation Page 9 XST USERS MANUAL Model XST 400 XST 600 XST 800 Capacity 400VA 240W 600VA 360W 800VA 480W Input Voltage 120 VAC Ra...