background image

IMPORTANT

 

SAFETY

 

INSTRUCTIONS:

 

(SAVE

 

THESE

 

INSTRUCTIONS)

 

CAUTION!

 

(UPS

 

having

 

Internal

 

Batteries):

 

Risk

 

of

 

electrical

 

shock

 

 

Hazardous

 

live

 

parts

 

inside

 

this

 

unit

 

are

 

energized

 

from

 

the

 

battery

 

supply

 

even

 

when

 

the

 

input

 

AC

 

power

 

is

 

disconnected.

 

CAUTION!

 

(No

 

User

 

serviceable

 

Parts):

 

Risk

 

of

 

electrical

 

shock,

 

do

 

not

 

remove

 

cover.

 

No

 

user

 

serviceable

 

parts

 

inside.

 

Refer

 

servicing

 

to

 

qualified

 

service

 

personnel.

 

CAUTION!

 

(Non

isolated

 

Battery

 

supply):

 

Risk

 

of

 

electric

 

shock,

 

battery

 

circuit

 

is

 

not

 

isolated

 

from

 

AC

 

input,

 

hazardous

 

voltage

 

may

 

exist

 

between

 

battery

 

terminals

 

and

 

ground.

 

Test

 

before

 

touching.

 

WARNING!

 

Unit

 

intended

 

for

 

installation

 

in

 

a

 

controlled

 

environment.

 

CAUTION!

 

Do

 

not

 

dispose

 

of

 

batteries

 

in

 

a

 

fire,

 

the

 

battery

 

may

 

explode.

 

CAUTION!

 

Do

 

not

 

open

 

or

 

mutilate

 

the

 

battery,

 

released

 

electrolyte

 

is

 

harmful

 

to

 

the

 

skin

 

and

 

eyes.

 

CAUTION!

 

A

 

battery

 

can

 

present

 

a

 

risk

 

of

 

electric

 

shock

 

and

 

high

 

short

 

circuit

 

current.

 

The

 

following

 

precaution

 

should

 

be

 

observed

 

when

 

working

 

on

 

batteries:

 

Remove

 

watches,

 

rings

 

or

 

other

 

metal

 

objects.

 

Use

 

tools

 

with

 

insulated

 

handles.

 

To

 

reduce

 

the

 

risk

 

of

 

electric

 

shock,

 

disconnect

 

the

 

UPS

 

from

 

the

 

main

 

supply

 

before

 

installing

 

a

 

computer

 

interface

 

signal

 

cable.

 

Reconnect

 

the

 

power

 

cord

 

only

 

after

 

signaling

 

interconnections

 

have

 

been

 

made.

 

Servicing

 

of

 

batteries

 

should

 

be

 

performed

 

or

 

supervised

 

by

 

personnel

 

with

 

knowledge

 

of

 

batteries

 

and

 

the

 

required

 

precautions.

 

Keep

 

unauthorized

 

personnel

 

away

 

from

 

batteries.

 

The

 

instructions

 

contained

 

within

 

this

 

safety

 

manual

 

are

 

deemed

 

important

 

and

 

should

 

be

 

closely

 

followed

 

at

 

all

 

times

 

during

 

installation

 

and

 

follow

up

 

maintenance

 

of

 

the

 

UPS

 

and

 

batteries

.

 

XST

 

USERS

 

MANUAL

 

Page

 

6

 

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

 

XTREME

 

POWER

 

CONVERSION

®

 

(XPC)

 

CORPORATION

 

LIMITED

 

WARRANTY

 

Xtreme

 

Power

 

Conversion

 

(XPC)

 

Corporation

 

warrants

 

Xtreme

 

Power

 

Conversion

 

equipment,

 

when

 

properly

 

applied

 

and

 

operated

 

within

 

specified

 

conditions,

 

against

 

faulty

 

materials

 

or

 

workmanship

 

(excluding

 

batteries)

 

for

 

a

 

period

 

of

 

two

 

years

 

for

 

XST

Series

 

products

 

from

 

the

 

date

 

of

 

purchase.

   

XPC

 

Corporation

 

warrants

 

internal

 

batteries

 

for

 

a

 

period

 

of

 

two

 

years

 

from

 

the

 

date

 

of

 

purchase.

 

For

 

equipment

 

sites

 

within

 

the

 

United

 

States

 

and

 

Canada,

 

this

 

warranty

 

covers

 

repair

 

or

 

replacement,

 

at

 

the

 

sole

 

discretion

 

of

 

XPC

 

Corporation.

 

The

 

customer

 

is

 

responsible

 

for

 

the

 

costs

 

of

 

shipping

 

the

 

defective

 

product

 

to

 

XPC

 

Corporation.

 

XPC

 

Corporation

 

will

 

pay

 

for

 

ground

 

shipment

 

of

 

the

 

repaired

 

or

 

replacement

 

product.

 

This

 

warranty

 

applies

 

only

 

to

 

the

 

original

 

purchaser.

 

If

 

equipment

 

provided

 

by

 

XPC

 

Corporation

 

is

 

found

 

to

 

be

 

Dead

on

Arrival

 

(DOA)

,

 

XPC

 

Corporation

 

will

 

be

 

responsible

 

for

 

the

 

costs

 

of

 

shipping

 

product

 

to

 

and

 

returning

 

equipment

 

from

 

the

 

customer

 

in

 

a

 

timely

 

manner

 

as

 

agreed

 

to

 

with

 

the

 

customer,

 

once

 

the

 

customer

 

has

 

requested

 

and

 

received

 

a

 

Return

 

Material

 

Authorization

 

(RMA)

 

number.

 

DOA

 

equipment

 

is

 

defined

 

as

 

equipment

 

that

 

does

 

not

 

properly

 

function

 

according

 

to

 

user

 

documentation

 

when

 

initially

 

received

 

and

 

connected

 

in

 

conjunction

 

with

 

proper

 

procedures

 

as

 

shown

 

in

 

the

 

user

 

documentation

 

or

 

via

 

support

 

provided

 

by

 

XPC

 

Corporation

 

personnel

 

or

 

authorized

 

agents.

 

This

 

warranty

 

shall

 

be

 

void

 

if

 

(a)

 

the

 

equipment

 

is

 

repaired

 

or

 

modified

 

by

 

anyone

 

other

 

than

 

XPC

 

Corporation

 

or

 

a

 

XPC

 

Corporation

 

approved

 

third

 

party;

 

(b)

 

the

 

equipment

 

is

 

damaged

 

by

 

the

 

customer,

 

is

 

improperly

 

used

 

or

 

stored,

 

is

 

subjected

 

to

 

an

 

adverse

 

operating

 

environment,

 

or

 

is

 

operated

 

outside

 

the

 

limits

 

of

 

its

 

electrical

 

specifications;

 

or

 

(c)

 

the

 

equipment

 

has

 

been

 

used

 

or

 

stored

 

in

 

a

 

manner

 

contrary

 

to

 

the

 

equipment’s

 

operating

 

manual,

 

intended

 

use

 

or

 

other

 

written

 

instructions.

 

Any

 

technical

 

advice

 

furnished

 

by

 

XPC

 

Corporation

 

or

 

a

 

XPC

 

Corporation

 

authorized

 

representative

 

before

 

or

 

after

 

delivery

 

with

 

regard

 

to

 

the

 

use

 

or

 

application

 

of

 

Xtreme

 

Power

 

Conversion

 

equipment

 

is

 

furnished

 

on

 

the

 

basis

 

that

 

it

 

represents

 

XPC

 

Corporations

 

best

 

judgment

 

under

 

the

 

situation

 

and

 

circumstances,

 

but

 

it

 

is

 

used

 

at

 

the

 

recipient’s

 

sole

 

risk.

 

EXCEPT

 

AS

 

STATED

 

ABOVE,

 

XPC

 

Corporation

 

DISCLAIMS

 

ALL

 

WARRANTIES,

 

EXPRESSED

 

OR

 

IMPLIED,

 

INCLUDING

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

AND

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE.

  

EXCEPT

 

AS

 

STATED

 

ABOVE,

 

IN

 

NO

 

EVENT

 

WILL

 

XPC

 

Corporation

 

BE

 

LIABLE

 

FOR

 

DIRECT,

 

INDIRECT,

 

SPECIAL,

 

INCIDENTAL,

 

OR

 

CONSEQUENTIAL

 

DAMAGES

 

ARISING

 

OUT

 

OF

 

THE

 

USE

 

OF

 

Xtreme

 

Power

 

Conversion

 

EQUIPMENT,

 

including

 

but

 

not

 

limited

 

to,

 

any

 

costs,

 

lost

 

profits

 

or

 

revenue,

 

loss

 

of

 

equipment,

 

loss

 

of

 

use

 

of

 

equipment,

 

loss

 

of

 

software,

 

loss

 

of

 

data,

 

cost

 

of

 

substitutes,

 

or

 

claims

 

by

 

third

 

parties..Purchaser’s

 

sole

 

and

 

exclusive

 

remedy

 

for

 

breach

 

of

 

any

 

warranty,

 

expressed

 

or

 

implied,

 

concerning

 

Xtreme

 

Power

 

Conversion

 

equipment,

 

and

 

the

 

only

 

obligation

 

of

 

XPC

 

Corporation

 

under

 

this

 

warranty,

 

shall

 

be

 

the

 

repair

 

or

 

replacement

 

of

 

defective

 

equipment,

 

components,

 

or

 

parts;

 

or,

 

at

 

XPC

 

Corporations

 

sole

 

discretion,

 

refund

 

of

 

the

 

purchase

 

price

 

or

 

substitution

 

of

 

an

 

equivalent

 

replacement

 

product.

  

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

                                  

Page

 

11

 

XST

 

USERS

 

MANUAL

 

Summary of Contents for XST?400

Page 1: ...Xtreme Standby Tower Series XST 400 600 800 User Manual Xtreme Power Conversion XPC Corporation XST USERS MANUAL Page 16 Xtreme Power Conversion XPC Corporation ...

Page 2: ... a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Product Overview The XST Series UPS provides comprehensive protection in a small and economical package This UPS is compact offering greater power The XST has been...

Page 3: ...ice b If the Product shows evidence of damage from a Power Disturbance XPC will request that all Connected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to you for either t...

Page 4: ... land line or PBX telephone equipment line that is properly installed and connected to an RJ11 port on the Product or by a Power Disturbance on a standard Local Area Network connection that is properly installed and connected to an RJ45 port on the Product and d is directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturb...

Page 5: ...d for on eBay b the price list of Orion Blue Book or if such price list is no longer published a published or announced price list reasonably selected by XPC c the lowest price the same or similar items can be purchased for in the United States or d the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or f...

Page 6: ...ration will pay for ground shipment of the repaired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the customer has requested...

Page 7: ...ing the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the model information about your UPS e Any information on the failure including LED s that may or may not be illuminated f A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if...

Page 8: ...y defect Replace the battery with the same type of battery The AC input is normal but the blue LED is flashing Power cord is loose Reconnect the input power cord properly When power fails backup time is shorter than expected Specifications Xtreme Power Conversion XPC Corporation Page 9 XST USERS MANUAL Model XST 400 XST 600 XST 800 Capacity 400VA 240W 600VA 360W 800VA 480W Input Voltage 120 VAC Ra...

Reviews: