background image

3

IMPORTANT SAFETY INFORMATION

NEVER

 use an extension cord longer than 25 feet. Minimum cord gauge must be 16, an undersized cord 

will cause a drop in line voltage resulting in a loss of power and overheating. 

ALWAYS

 use your hand to operate the control lever and the switch. NEVER use your foot or any extension 

device. 

NEVER

 modify the plug provided if it will not fit the outlet. Have the proper outlet installed by a qualified 

electrician.

ALWAYS

 use a 3-wire extension cord with 3-prong grounded plugs and a 3-pole receptacles that accept 

this plug

NEVER

  loosen  or  remove  the  hydraulic  fitting  or  the  cap  of  the  hydraulic  tank  while  the  log  splitter  is 

running. 

NEVER

 operate your log splitter when it is in poor mechanical conditon or in need of repair. 

ALWAYS

 unplug the power cable before performing any maintenace and repair. Periodically check all 

nuts, bolts, screws hydraulic fittings and be sure the hose clamps are tightened. 

NEVER

 tamper with the motor to run it at excessive speeds. The maximum motor speed is preset by the 

manufacturer and is within safety limits. 

NEVER

 adjust the hydraulic valve. The system is preset at the factory and is within safety limits. 

ALWAYS

 check the level of hydraulic oil before operation. 

ALWAYS

 Repair or replace a damaged power cord immediately.  

NEVER

 check for leaks of hydraulic fluids with your hand. Fluid escaping from a small hole can be almost 

invisible. Escaping fluid under pressure can have sufficient force to penetrate skin, causing serious injury 

or even death. Leaks can be detected by passing a piece of cardboard over the suspected leak and looking 

for discoloration. 

ALWAYS

 seek medical attention immediately if injured by escaping hydraulic fluid. Serious infection or 

physical reaction can develop. 

ALWAYS

 be sure to relieve all pressure by shutting off the negine amd moving the valve control handle 

back anf forth should it become necessary to loosen or remove the hydraulic fitting. 

NEVER

 remove the cap from the hydraulic tank or reservoir while the log splitter is running. Hot oil under 

pressure could result in serious injury. 

NEVER 

adjust the hydraulic valve, the pressure relief valve on your log splitter is preset at the factory. Only 

a qualified service technicial should perform this adjustment. 

NEVER

 

operate your log splitter near a flame or spark, hydraulic fluid is flammable and can explode. 

ALWAYS

 have a CLASS B fire extinguisher with you when operating this log splitter in dry areas as a pre

-

cautionary measure. 

NEVER

 move this log splitter while the motor is running. 

NEVER 

carry cargo or wood on your log splitter. 

SAVE THESE WARNINGS

Summary of Contents for 65061-XP

Page 1: ... INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 65061 XP FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...g in USE RECOMMENDED ACCESSORIES Consult the owner s manual for recommended accessories NEVER STAND ON TOOL Serious injury can occur if the tool is tipped or if the cutting tool is unintentionally contacted NEVER LEAVE TOOL RUNNING UNATTENDED TURN POWER OFF DO NOT OPERATE WITH ANY GUARD THAT IS DISABLED DAMAGED OR REMOVED Keep guards in place and in good working order Wear ANSI approved safety gog...

Page 3: ...f injury Set up and operate only on a flat level dry and solid surface with wheels chocked When servicing use only identical replacement parts Only use safety equipment that has been approved by an appropriate standards agency Maintain labels and nameplates on the tool These carry important safety information If unreadable or missing contact Stark Tools for a replacement Avoid unintentional starti...

Page 4: ...ulic oil before operation ALWAYS Repair or replace a damaged power cord immediately NEVER check for leaks of hydraulic fluids with your hand Fluid escaping from a small hole can be almost invisible Escaping fluid under pressure can have sufficient force to penetrate skin causing serious injury or even death Leaks can be detected by passing a piece of cardboard over the suspected leak and looking f...

Page 5: ...ansmission fluid can be substituted Use only clean oil and be sure to prevent dirt from entering the hydraulic reservoir Do not mix AW32 hydraulic fluid with Dextron hydraulic flud Log splitter is shipped with AW32 hydraulic fluid IMPORTANT Before operating the log splitter turn the bleed screw two turns to allow air to be released from the hydraulic system A flow of air through the bleed screw sh...

Page 6: ... device circuit breaker for over or under voltage 7 Place a log on the beam against the push plate Make sure the log is securely on the beam and up against the push plate Logs should be cut with square ends and to a maximum length of 20 in advance Always use extra care when splitting logs with unsquare ends 8 Two controls must be activated to operate the log splitter The hydraulic control lever an...

Page 7: ...rely 9 Lower the log splitter Allow the log splitter to cool down for five minutes before storing Switch off and unplug the log splitter before storing Protect the power supply cable from heat sunlight agressive liquids and sharp edges Store the unit in a clean dry area Do not store outdoors or next to corrosive materials or in a damp environment Store the log splitter out of reach of children STO...

Page 8: ...PARTS DIAGRAM 7 ...

Page 9: ...PARTS LIST 8 ...

Page 10: ...c oil with the dipstick 6 For other hydraulic and motor problems not addressed in this manual contact a qualified technician 7 If the wedge is dull or nicked sharpen it Always wear safety glove while handling the wedge 8 All replacements parts must meet the manufacturers specifications Note If the motor is overloaded for a long time the thermal protector will disconnect the power of the the motor ...

Page 11: ...THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number record mo...