background image

4

INSTALLATION

PUMP LOCATION AND MOUNTING:

• THE SYSTEM MUST BE INSTALLED ON A SOLID LEVEL AND VIBRATION-FREE BASE.

• PROVIDE A LOCATION PROTECTED FROM THE WEATHER, MOISTURE, FLOODING AND

FREEZING TEMPERATURE.

• PROVIDE ADEQUATE ACCESS, SPACE AND LIGHTING FOR ROUTINE MAINTENANCE.

• PUMP MOTOR REQUIRES FREE CIRCULATION OF AIR FOR COOLING. DO NOT INSTALL

THE  PUMP  IN  A  DAMP  OR  NON-VENTILATED  LOCATION.  A  TEAM  OF  2  OR  MORE  PEOPLE  IS 

RECOMMENDED FOR SETTING UP THIS PRODUCT.

MOTOR PRE-FILTERING ASSEMBLY SETUP:

1. REMOVE THE SAND FILTER AND ITS ACCESSORIES FROM THE PACKAGING CAREFULLY AND 

INSPECT FOR ANY VISIBLE DAMAGE. IF PARTS ARE DAMAGED CONTACT YOUR LOCAL SERVICE 

CENTER LISTED AT THE BACK OF THIS OWNER’S MANUAL.

2. IN A COUNTER-CLOCKWISE MOTION UNSCREW THE LEAF TRAP COVER (14) FROM THE PRE-

FILTER HOUSING. TAKE OUT THE BASKET (16) AND FILTER HOUSING NUT (17) (SEE DRAWING 10).

3.  CONNECT  THE  PRE-FILTER  HOUSING  TO  THE  MOTOR  WATER  INLET.  NOTE:  ALIGN  THE 

CONNECTOR IN THE PRE-FILTER HOUSING WITH THE WATER INLET ON THE MOTOR.

This pump utilizes advanced technology with the feature of an automatic timing controller. In accordance 

with the following simple yet effective preventative measures when installing the Sand Filter Pump.                                   
1. Make sure to tighten the anchor bolts in order to avoid the influence of vibrational movements. 

2. The suction hose of the pump should be larger than 40mm and its diameter must be equal or larger than 

the siameter of the release hose. 

3. 

DO NOT

 allow any air to enter the pump while it is running. 

4. The pump must be connected to the correct power supply and voltage. This can be found on the nameplate 

label. 

5. Connections should be made by a qualified technician. 
6. The suction hose must be continuously tilted upwards from the bottom. The joint should be tight but not 

too tight. 

7. The ideal temperature for a working pump is  0 °C - 40 °C. If the temperature is too high or low, the pump 

will stop working. Otherwise it may damage the filter and pump. 

8. A ground lead must be used to protect the motor. 

9. To avoid deforming the pump, the weight of the installed hoses should not be added to the pump. 

Summary of Contents for 75159

Page 1: ...SEMBLY OPERATING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75159 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...s Improper installation may create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property To reduce the risk of injury do not permit children to use or operate this pump and sand filter Do not bury the electrical cord Locate the cord where it will not be damaged by lawn mowers hedge trimmer...

Page 3: ...bled for storage and reassembled to its original integrity A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage The suction and relief valve must be opened before starting the circulating system of the pump Doing so may result in injury or property damage WARNING Electric Shock Hazard MAKE SURE to shut off the powe...

Page 4: ... F Suction outlets shall be reconfigured into return inlets This filter operates under high pressure When any part of the circulating system e g clamp pump filter valves etc is serviced air can enter the system and become pressurized Pressurized air can cause the lid or control valve to separate which may result in serious injury death or property damage To avoid this potential hazard follow these...

Page 5: ...re to ground the motor can cause serious or fatal electrical shock hazard DO NOT ground to a gas supply pipe line FOR CORD AND PLUG CONNECTED UNITS Connect only to a ground type receptacle protected by a Ground Fault Circuit Interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI Do Not Bury Cord Locate cord to minimize abuse from lawn mowers ...

Page 6: ... PRE FILTER HOUSING WITH THE WATER INLET ON THE MOTOR This pump utilizes advanced technology with the feature of an automatic timing controller In accordance with the following simple yet effective preventative measures when installing the Sand Filter Pump 1 Make sure to tighten the anchor bolts in order to avoid the influence of vibrational movements 2 The suction hose of the pump should be large...

Page 7: ...e the tank as above picture shows then place the funnel on the tank s mouth and out the quartz sand into the tank A 12 sand filter requires about 19kg of sand to fill the tank a 14 sand filler needs about 27kg of sand to fill the tank 4 Remove the funnel and make sure the tank s neck is clean Put the O ring on the valve and use clamp to fix the valve with the tank Pump port valve direction needs t...

Page 8: ... Do not over tighten fittings or adapters HOW TO USE 1 Inspect all connections have been made and are secure 2 Depress the top mount valve handle and rotate to BACKWASH position 3 Prime and start pump according to the pump instructions NOTE All suction and discharge valves must be opened when starting the system Failure to do so can cause severe personal injury Make sure the filter vessel are full...

Page 9: ... configured to avoid electric shock when deterioration of the insulation occurs due to product age CONTROL PANEL INSTRUCTION TIMER INITIATION NOTE Make sure the power supply is off 1 Unscrew the four screws on the lid of the terminal box and remove the lid 2 Remove the battery 3 Remove the rubber film on the surface of the battery 4 Replace the battery 5 Replace the lid on the terminal box and re ...

Page 10: ...6h 24h Then press the ON OFF button the pump should start running The running time is what the indicator light shows TIMES ON OFF 2h 4h 6h 8h 10h 12h 16h 24h TIMES ON OFF 2h 4h 6h 8h 10h 12h 16h 24h SINGLE CYCLE MODE Depressing the TIMER button more than 10 seconds the Single Cycle Indicator light will flash and switch to Single Cycle mode In the Single Cycle Mode press ON the pump will work and S...

Page 11: ...n good condition If any parts are worn cracked or in bad condition replace them prior to starting the pump The pump should be stopped immediately if the temperature is too high Inspect and if need be have a technician repair it If loud noises are coming from the pump turn the power off immediately and have a service technician service and repair it TROUBLESHOOTING ...

Page 12: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...

Reviews: