4
INSTALLATION
PUMP LOCATION AND MOUNTING:
• THE SYSTEM MUST BE INSTALLED ON A SOLID LEVEL AND VIBRATION-FREE BASE.
• PROVIDE A LOCATION PROTECTED FROM THE WEATHER, MOISTURE, FLOODING AND
FREEZING TEMPERATURE.
• PROVIDE ADEQUATE ACCESS, SPACE AND LIGHTING FOR ROUTINE MAINTENANCE.
• PUMP MOTOR REQUIRES FREE CIRCULATION OF AIR FOR COOLING. DO NOT INSTALL
THE PUMP IN A DAMP OR NON-VENTILATED LOCATION. A TEAM OF 2 OR MORE PEOPLE IS
RECOMMENDED FOR SETTING UP THIS PRODUCT.
MOTOR PRE-FILTERING ASSEMBLY SETUP:
1. REMOVE THE SAND FILTER AND ITS ACCESSORIES FROM THE PACKAGING CAREFULLY AND
INSPECT FOR ANY VISIBLE DAMAGE. IF PARTS ARE DAMAGED CONTACT YOUR LOCAL SERVICE
CENTER LISTED AT THE BACK OF THIS OWNER’S MANUAL.
2. IN A COUNTER-CLOCKWISE MOTION UNSCREW THE LEAF TRAP COVER (14) FROM THE PRE-
FILTER HOUSING. TAKE OUT THE BASKET (16) AND FILTER HOUSING NUT (17) (SEE DRAWING 10).
3. CONNECT THE PRE-FILTER HOUSING TO THE MOTOR WATER INLET. NOTE: ALIGN THE
CONNECTOR IN THE PRE-FILTER HOUSING WITH THE WATER INLET ON THE MOTOR.
This pump utilizes advanced technology with the feature of an automatic timing controller. In accordance
with the following simple yet effective preventative measures when installing the Sand Filter Pump.
1. Make sure to tighten the anchor bolts in order to avoid the influence of vibrational movements.
2. The suction hose of the pump should be larger than 40mm and its diameter must be equal or larger than
the siameter of the release hose.
3.
DO NOT
allow any air to enter the pump while it is running.
4. The pump must be connected to the correct power supply and voltage. This can be found on the nameplate
label.
5. Connections should be made by a qualified technician.
6. The suction hose must be continuously tilted upwards from the bottom. The joint should be tight but not
too tight.
7. The ideal temperature for a working pump is 0 °C - 40 °C. If the temperature is too high or low, the pump
will stop working. Otherwise it may damage the filter and pump.
8. A ground lead must be used to protect the motor.
9. To avoid deforming the pump, the weight of the installed hoses should not be added to the pump.