background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

7

 

 

A.  ACTIVATING BLOWER FUNCTION: 

  Option 1: Touch and hold down (+) for 1-2 seconds. 

  Option 2: Touch and hold down power sign (1) for 1-2 seconds. (The blower will be running at the same speed as last used). 

Note

: The system saves user configurations, settings such as timer and blower (motor) speed will remain the same the next time it is turned on. 

 
B.  ADJUSTING BLOWER SPEED: 

  Touch and hold down (+) for increase. 

  Touch and hold down (-) for decrease. 

 
C.  TURNING OFF THE BLOWER: 

  Touch and hold down power sign (1) for 1-2 seconds.       

 
D.  TO TURN THE LIGHT ON/OFF: 

  Touch Light button (6) once to turn on the lights, and once again to turn off the lights. 

 
E.  ADJUSTING THE TIMER FUNCTION:   

  While the blower (motor) is not running, touch and hold Decrease Value button (2) over 3 seconds (until it’s flashing) to enter timer mode.   

  Adjust to desired period of delay off timer by touching Increase Value or Decrease Value 

button (minimum 1 minute to maximum 15 minutes). 

This setting will be saved immediately.   

 

F. ACTIVATING THE TIMER FUNCTION:   

  While the blower (motor) is running, touch and hold “Power” button (1) for over 3 seconds to activate delay off timer.   

Power-Off Delay Timer Indicator

   

(10) will light up and 

Power-Off Delay Digital Timer

 (9) will begin to countdown.    When it reaches zero, the blower (motor) will shut down.

 

 
G.  TO CLEAR CLEANING REMINDER: 

  When blower (motor) starts to rotate, cumulative running time will be shown in 

Power-On Elapsed Digital Timer (8)

. This timer icon flashes when 30 hours 

is up and reminds user to clean the baffle filters.   

  After cleaning the filters and when the motor is not in use, touch and hold (+) 

Increase Value 

button (7) over 3 seconds to reset the timer. Please note 

that turning off the system will not reset the 

Power-On Elapsed Digital Timer (8)

.   

 

   

 

Body Design   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Power Rating   

120V/60Hz (USA & Canada standard) 

General Input Power   

158W (150W + 4x2W) 

Motor Input Power   

150 W each 

Ampere   

1.3 A 

Levels Of Speed Control 

4 Levels 

Maximum Airflow 

900CFM 

Noise Level 

Approximately 1.5 – 6.0 sones or 33 – 54 dB 

Number Of Motors   

Single Motor 

Motor Type   

Single Chamber Ultra Quiet 

Fan Type   

Squirrel Cage blower 

Filtration Type   

Heavy Duty Stainless Steel Baffle Filter 

Illumination   

4 LED lights, 2W Maximum/each 

Venting Size   

Top 6 inches Round 

Interference Protection   

Radio Frequency Interference Protected 

Note 

Specification subject to change without notice. 

 

 

1.    If the range hood or lights does not operate after installation: 

 

Check if the range hood has been plugged in.    Make sure that all power has been turned back ON. Check if the fuse is not blown and all electrical wiring is 
properly connected. 

 

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs. See 

replacing the light bulbs 

on Page 13. 

2.    The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly on to the ceiling or wall. 

 

Check if the motor is secured in place.    If not, then tighten the motor in place. Check if the blower wheel is damaged.       
 
 

11. SPECIFICATION 

12. TROUBLESHOOTING 

Summary of Contents for PX05-I36

Page 1: ...www XtremeAirUsa com PAGE 1 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY INSTALLATION GUIDE USER S MANUAL ISLAND MOUNT RANGE HOOD Model Pro X Series PX05 I36 I42...

Page 2: ...llation in this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professi...

Page 3: ...s with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of you...

Page 4: ...nch Ceiling mount bracket depth Ceiling mount bracket perimeter height Ceiling mount bracket width Upper chimney length Lower chimney length Body depth I36 I42 models Body width I36 I42 models Body he...

Page 5: ...ckets at all 4 corners with bolts F Connect the ductwork to the range hood Use aluminum tape to secure the pipe joint area G Connect power plug CAREFULLY REMOVE CHIMNEY PROTECTIVE FILM Set the lower H...

Page 6: ...e 3 7 To increase blower motor speed increase timer value and cumulative timer reset 4 3 Blower motor is running light indicator 5 4 Shows current blower motor speed 1 4 6 5 Lights up when lights turn...

Page 7: ...Timer 8 This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters After cleaning the filters and when the motor is not in use touch and hold Increase Value button 7 ove...

Page 8: ...ts to clean without proper instructions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY...

Page 9: ...www XtremeAirUsa com PAGE 9 15 LIMITED WARRANTY...

Reviews: