background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

7

 

 

C.    Activating Power-Off Delay Function: 

1.  While the range hood is on and the blower is running in normal mode, touch 

Power-Off Delay 

button to activate delay off timer.   

2.

  Adjust to desired period of delay of timer by touching (-)

 

or (+)

 

button quickly (1-15 minutes). Timer begins to countdown immediately, when it       

reaches 0, the blower will shut off.

 

3.

  Display screen will show flashing clock if timer is working.

 

 
D.    Activating Smoke Detector Function: 

                                While the machine is off, touch 

Auto Function 

button to activate the smoke detector auto function mode.   

  NOTE: this function will only worked when there’s a lot of smoke.    Once this button is touched, all other buttons are not active. 

 

E.    Changing the clock (only available in some models) 

          While the blower is off: 

          1. Touch power sign once. The hour indicator will be flashing. 
          2. Use (+) or (-) to adjust to the desired hour. 
          3. Touch power sign again for the “minutes”. Indicator will be flashing. 
          4. Use (+) or (-) to adjust to desired minutes. 
          5. Touch power sign again to clear the screen. Touch light button to validate. To check time, touch light button. 
              NOTE: The clock display is only available for product manufactured after October 2013. 

F.    Remote Control Sensor: 

1.

  Remote control sensor receives infrared (IR) signal from the remote control. The maximum distance for IR data transmission is 10 

feet and requires direct line of sight. The transmission distance may vary depending on temperature and remote control battery 
condition.

 

2.    Light settings are independent from other settings (including power-off delay) and lights have to be manually turned on or off.   

3.

  The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is   

 

    turned on. 

 

     

 

PX07-I36 & PX06-I42 

PX07-I48 

Body Design   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Power Rating   

120V/60Hz (USA & Canada standard) 

120V/60Hz (USA & Canada standard) 

General Input Power   

158W (150W + 4x2W) 

308W (150W + 4x2W) 

Motor Input Power   

150 W each 

150 W each 

Ampere   

1.3 A 

2.6 A 

Levels Of Speed Control 

4 Levels 

4 Levels 

Maximum Airflow 

900CFM 

1600CFM 

Noise Level 

Approximately 1.5 – 6.0 sones or 33 – 54 dB 

Approximately 3.0 – 7.0 sones or 41 – 56 dB 

Number Of Motors   

Single Motor 

2motors 

Motor Type   

Single Chamber Ultra Quiet 

Single Chamber Ultra Quiet 

Fan Type   

Squirrel Cage blower 

2 Squirrel Cage blowers 

Filtration Type   

Heavy Duty Stainless Steel Baffle Filter 

Heavy Duty Stainless Steel Baffle Filter 

Illumination   

4 LED lights, 2W Maximum/each 

4 LED lights, 2W Maximum/each 

Venting Size   

Top 6 inches Round 

Top 8 inches Round 

Interference Protection   

Radio Frequency Interference Protected 

Radio Frequency Interference Protected 

Note 

Specification subject to change without notice. 

Specification subject to change without notice. 

 

 

 

 

1.    If the range hood or lights does not operate after installation: 

  Check if the range hood has been plugged in.    Make sure that all power has been turned back ON.   

 

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs.   

 

 

2.    The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly to the cabinet or wall. 

 

Check if the blower wheel is damaged.       

11. SPECIFICATION 

12. TROUBLESHOOTING 

 

 

 

A.Make sure the range hood is unplugged or turn OFF breaker.   
B.Pop out the light by pressing behind the light fixture. 
C.Install new light bulb. 
D.Put the light set back by pressing it in. 
E.Plug in and range hood to test for operation. 

 

Summary of Contents for PX07-I36

Page 1: ...www XtremeAirUsa com PAGE 1 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY INSTALLATION GUIDE USER S MANUAL ISLAND MOUNT RANGE HOOD Model Pro X Series PX07 I36 I42 I48 ...

Page 2: ...ion in this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It...

Page 3: ...d or fire hazard Hoods mounted too high will be hard to reach and will lose its performance and efficiency Use metal ductwork only DO NOT use plastic ventilation DO NOT use 4 10 2 cm laundry type wall caps Fasten all connections with sheet metal screws Tape all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If ...

Page 4: ...NT DUE TO THE WEIGHT AND SIZE OF THIS UNIT CEILING BRACKET MUST BE MOUNTED TO A WEIGHT BEARING CEILING SUPPORT SYSTEM OR FRAMEWORK BEING USED IS STABLE AND SECURE ON THE CEILING ABLE TO SUPPORT AT LEAST TWICE THE WEIGHT OF THE HOOD D1 D2 D3 D4 D5 D6 D7 D9 10 5 inch 3 8 inch 12 5 8 inch 23 0 inch 19 0 inch 23 6 inch 35 75 41 75 47 7 inch 12 8 inch Ceiling mount bracket depth Ceiling mount bracket p...

Page 5: ...sure SLOT and HOOK are snapped D Attached air diverter AD to hood body for PX07 I48 only E Have a third person raise up the hood body into its position It should be directly under the support brackets F Attach the hood to the support brackets at all 4 corners with bolts G Connect the ductwork to the range hood Use aluminum tape to secure the pipe joint area H Connect power plug HINT Due to the hea...

Page 6: ...t from lowest speed F1 Touch to start from Highest speed F4 Touch or again to change the blower speed as indicated in LCD panel B Activating Light Function Touch Light button to turn the lights on or off 10 RANGE HOOD OPERATION Figure 1 Figure 2 Figure 1A Figure 2A STEP 6 INSTALL REMOVE BAFFLE FILTERS Refer to picture at left for the following steps 1 Angle baffle filter toward front of hood or co...

Page 7: ...as light timer and blower motor speed will remain the same the next time it is turned on PX07 I36 PX06 I42 PX07 I48 Body Design Non Magnetic 1 0 mm Stainless Steel Satin Finish Non Magnetic 1 0 mm Stainless Steel Satin Finish Power Rating 120V 60Hz USA Canada standard 120V 60Hz USA Canada standard General Input Power 158W 150W 4x2W 308W 150W 4x2W Motor Input Power 150 W each 150 W each Ampere 1 3 ...

Page 8: ...ommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Clean...

Page 9: ...www XtremeAirUsa com PAGE 9 15 LIMITED WARRANTY ...

Reviews: