Installation of air purifier - MiracleAir 400-B units 

-

 

No further installation is required after unpacking and positioning Miracleair filter unit. 
 

3.3.

 

Electrical installation - connection to the electrical network 

3.3.1.

 

General information - safety 

-

 

Before starting the installation, make sure that the mains socket you intend to use to connect the unit 
is equipped with a protective contact (pin).  

-

 

The mains plug must always remain accessible

 

so that the unit may be safely disconnected from the 

mains in the event of danger. 

-

 

Verify that the outlet meets power requirements of the unit (voltage, current, frequency etc.) listed on 
the production plate of the unit. 

-

 

The relevant circuit must be protected in the power supply to maximum of 16 A. 

-

 

The mains cable must not be broken. 

-

 

Local electrical regulations must always be observed 

-

 

When handling the unit, disconnect the device from the mains first (pull out the mains socket) 

-

 

It is forbidden to tamper with the internal wiring of the unit in any way 

-

 

This unit belongs to the product group with type Y connection. If the mains cable is damaged, it must 
be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a 
high-risk situations. 

-

 

The supply voltage to the fan 1~230V / 50-60Hz must not be altered in any way. Otherwise there is a 
risk of damage to the unit fan. 
 

3.3.2.

 

Mains connection 

-

 

the unit is supplied with a power supply cable with a flex plug with a protective contact. The length of the 
mains cable is 2.7 m.

 

-

 

The unit is equipped with a 1-pole mains switch, which can be used to switch the power supply on and 
off. 

 

-

 

Connecting the unit to the mains does not require any further electrical connections, interconnections.

 

3.3.3.

 

 

Labelling of electrical parameters 

-

 

all electrical parameters of the unit are shown on the production label 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 11 

Type: product type 

Voltage (U): XXX V AC Frequency (f): XX/XX Hz 
Current (I): XXX A 

Weight (m): XX kg 

Input (P): XXX W 

IP: 

XX 

Serial number 

MADE IN CZECH REPUBLIC 

EAN of the product

 

Summary of Contents for MiracleAir 300-A1

Page 1: ...1 Version 1 GBR 05 05 2020 D 502 0173 INSTRUCTIONS FOR USE AND INSTALLATION OF MIRACLEAIR EXTRACTION AND FILTRATION UNITS ...

Page 2: ... 1 6 Main switch position 7 7 2 1 1 7 Power cable with plug position 8 7 2 1 2 Air purifier MiracleAir 400 B unit 7 2 1 2 2 Filtration box 8 2 1 2 3 Design side panels 8 2 1 2 4 Fan box with control panel 8 2 1 2 5 Main switch position 7 8 2 1 2 6 Power cable with plug position 8 8 2 2 Main dimensions of Miracleair aerosol extraction unit and the air purifier 8 2 2 1 MiracleAir 300 A1 aerosol extr...

Page 3: ...sition 1 14 4 2 1 2 Signal diode 14 4 2 1 3 Indicator of filter box clogging signalisation of need for filter box replacement 14 5 Wiring diagram of MiracleAir units 15 6 Commissioning 16 6 1 Before the first operation check the following 16 6 2 Switching on 16 6 3 Setting the correct power of the unit 16 6 3 1 Setting the output of the MiracleAir 300 A aerosol exhaust 16 6 3 2 Setting the output ...

Page 4: ...k of electric shock Connection of protective conductor Indicates the correct position when handling and storing the packaging Cautions about the need for protection against moisture Product packaging labelled with this symbol may not be transported in open vehicles and stored in uncovered buildings and on the ground without a pad Draws attention to the fragility of the product contents and need fo...

Page 5: ...x it is necessary to check the packaging for any signs of damage In case of damage to the packaging please contact your carrier Check that the delivery truly contains the product you ordered After unpacking check that the unit and other components are not damaged Report any discrepancy with the ordered products immediately to the supplier If the complaint is not made immediately after the delivery...

Page 6: ...traction unit with a special arm MiracleAir 300 A1 1 ARM 1 fixed 2 ARM 2 with flexible end 3 EXTRACTION BOX 4 FILTRATION BOX COARSE PARTICULATE FILTER PREFILTER HEPA FILTER FILTER WITH ACTIVATED CARBON 5 DESIGN SIDE PANELS 2 PCS 2 1 4 6 6 FAN BOX WITH CONTROL PANEL 7 MAIN SWITCH 8 POWER CABLE WITH PLUG 7 8 3 5 ...

Page 7: ...se particle filter filtration stage 2 pre filter class F7 ISO ePM1 65 ISO ePM2 5 95 filtration stage 3 HEPA H13 ISO ePM1 99 95 filtration stage 4 activated carbon filter to remove odours 2 1 1 4 Design side panels position 5 1 mm thick sheet steel construction treated with RAL 9003 anti corrosion powder paint and protective varnish to increase resistance to disinfection products 2 1 1 5 Fan box wi...

Page 8: ... to remove odours 2 1 2 3 Design side panels 1 mm thick sheet steel construction treated with RAL 9003 anti corrosion powder paint and protective varnish to increase resistance to disinfection products 2 1 2 4 Fan box with control panel 1 mm thick sheet steel construction treated with RAL 9003 anti corrosion powder paint and protective varnish to increase resistance to disinfection products The bo...

Page 9: ...ull version of the EC Declaration of Conformity is available on our website www xvent cz in the MiracleAir product documents 3 Unit installation 3 1 General information recommendations and safety when installing MiracleAir unit 3 1 1 Electrical safety before unit installation Before starting any installation work make sure that the intended mains socket is equipped with a protective contact pin ...

Page 10: ...ents of the unit voltage current etc listed on the production plate of the unit 3 1 2 Unpacking 3 1 2 1 Unpacking the MiracleAir Unit box 1 always unpack the unit in a space large enough to allow for removing the unit from the package Proceed as follows 3 1 2 2 Unpacking the suction arm box 2 only in the case of the MiracleAir 300 A1 aerosol extractor Remove the suction arm from the top box as fol...

Page 11: ...the damage to the fan or increased noise level of the unit The minimum distance of the suction nozzle from the extraction space is not specified However the recommended minimum distance is 0 15 m Consider the fact that vacuum is generated in the suction nozzle which can result in unwanted objects being sucked in e g sterile tampons cellulose etc 3 1 4 2 Air purifier MiracleAir 400 B unit The minim...

Page 12: ...t into any position Subsequently check the positioning functionality of the flexible arm end by setting into any position In case of need to extend the flexible part of the arm pull at it to extend it by approx 15 cm Turning positioning and extending of the arm should be possible without using excessive force 3 2 2 Installation of a protective sleeve The sleeve is disposable and is used for easier...

Page 13: ... the mains first pull out the mains socket It is forbidden to tamper with the internal wiring of the unit in any way This unit belongs to the product group with type Y connection If the mains cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a high risk situations The supply voltage to the fan 1 230V 50 60Hz must not be alte...

Page 14: ...cated on the back of the unit or by unplugging the power cord from the power outlet 4 2 1 2 Signal diode Indicates operation of the unit If the LED is ON the unit is active If it is not lit the unit is turned off 4 2 1 3 Indicator of filter box clogging signalisation of need for filter box replacement The orange indicator activates when the filter box is clogged At the same time it informs the use...

Page 15: ...15 Version 1 GBR 05 05 2020 D 502 0173 5 Wiring diagram of MiracleAir units internal wiring diagram of the unit Fig 14 ...

Page 16: ...he arm to the supposed operating position If necessary the arm may be extended by 15 cm in the flexible part to increase its reach Use adequate force when adjusting the arm to the desired position to avoid damage to the arm or tipping the unit over After starting the unit for the first time check the basic performance of the unit 6 3 Setting the correct power of the unit 6 3 1 Setting the output o...

Page 17: ... cleaning of Miracleair units Before any maintenance and cleaning of the unit the unit must be disconnected from the power supply unplug the mains cable 7 1 Regular maintenance inspection 7 1 1 General information Perform a regular visual inspection of particulate filter clogging top filter in the filter box The filter also captures inadvertently sucked components which can significantly reduce th...

Page 18: ...e coupling and at the measuring points o Check that the pressure caps are tightened correctly they must not be loose If necessary the cap must be opened then tighten the clip by 1 turn 360 and then re tighten it Always tighten the pressure caps one at a time The unit is designed and manufactured so that it does not require any special maintenance 7 1 2 Filter box replacement The filter box may con...

Page 19: ...d o Operating power of the unit the more air the unit filters the sooner the filter box becomes clogged After the light comes on immediately replace the filter box with a new one as follows a Switch off the unit using the main control knob to the OFF position and the main switch from the back of the unit to the position 0 b Disconnect the unit from the power supply by removing the plug of the main...

Page 20: ...th connectors and for connectors for the hose from the side of the unit e If operating the unit with a suction arm slide the arm out and store it in a safe place to prevent damage DISCONNECTION OF EARTH CONNECTOR 1 PUSHING THE BLUE CIRCLE DOWN 2 REMOVING THE HOSE FROM THE CONNECTOR DISCONNECT BOTH CONNECTORS FROM THE EARTH Fig 19 Fig 20 ...

Page 21: ...ssure caps on the fan box of the unit and release them from the hook on the filter box h Remove the plastic bag from the packaging of the replacement filter box and slide it on the clogged filter on the unit Do not clean the filter box Tapping on it or blowing through it with compressed air destroys the filter medium and harmful substances which are trapped in the box will be released into the air...

Page 22: ... Put the covered filter box in the bag back into the box Store the clogged filter box in a safe place for 3 days virus inactivation and then dispose of it as mixed waste according to local regulations j Install a new filter box The arrow on the filter box must point upwards Take care to avoid damage the the seal on the filter box and follow the proper positioning on the fan chamber Always replace ...

Page 23: ...e caps between it and the filter box Take care to avoid damage the the seal on the filter box and follow the proper positioning on the filter box Each new filter box is equipped with a new seal to keep the entire assembly tight If the pressure cap cannot be tightened or excessive force is necessary repeat the procedure and adjust the pressure as in the previous point k m Attach the extraction box ...

Page 24: ...ive disinfection to disinfect the unit and arm surfaces 7 2 2 Cleanable surfaces The unit and the suction arm may be cleaned over their entire outer surface The extraction outlet may be cleaned both from the inside and from the outside The unit may be cleaned from the inside only at the extraction box When cleaning take care not to damage the components protruding into the inner space of the extra...

Page 25: ...ng At the end of the service life of the device or when the repairs would not be economically viable disassemble the machine completely When disassembling the machine it is necessary to observe generally applicable safety regulations to safely perform all work After the complete disassembly of the machine the individual parts are to be disposed of in accordance with the requirements of the waste a...

Page 26: ...ty it is necessary to submit a report available in the product documentation which contains the following data on the complainant company date and number of the sales document detailed description of the failure information on socket protection photo of the production label or serial number of the product photo from the installation site of the product measured values of the product air temperatur...

Reviews: