5015SLR Flat Panel Industrial Touch Monitor Chapter 2 – Installation
11
144812(D)
Figure 2-9. Fastening the Monitor to the Panel
Caution
Over-tightening the clips can cause damage to the monitor, which can result
in loss of seal integrity.
Power Management
The monitor is based on the VESA DPMS and the DVI DMPM standards. To
activate the monitor's Power Management function, both the video card and the
computer
must
conform to the VESA DPMS standard and the DVI DMPM standard.
System Power
It is a good practice to use isolation transformers on the incoming AC power line to
the system. An isolation transformer is especially desirable in cases in which heavy
equipment is likely to introduce noise onto the AC line. The isolation transformer can
also serve as a step-down transformer to reduce the incoming line voltage to a desired
level. The transformer should have a sufficient power rating (units of volt-amperes)
to supply the load adequately.
Proper grounding is essential to all safe electrical installations. Refer to the relevant
federal, state/provincial, and local electric codes, which provide data such as the size
and types of conductors, color codes and connections necessary for safe grounding of
electrical components. The code specifies that a grounding path must be permanent
Panel
Display
Unit
Mounting Clip