Page | 67
Fill in the site information with as much
detail as possible. The
Site ID
should be
configured to the Ai1 serial number as this
cannot be changed later.
Select Data Setup tab and tick Clear
Registration under Login Id. Click ok on the
popup confirming manual registration
Save the site, then navigate to the
Dashboard view, highlight the site just
created and select View Site from the
bottom of the pop-up window.
Once the site is displayed, Select
Edit
from
the
⋮
menu.
Navigate to the
Data Setup
tab and note
the string that now appears under
Login Id
,
i.e., IfKlE-1DBHx-M1qSf-BBFig in this
instance.
13.3.2
Datalogger Configuration
The program configuration related to Hydrosphere is in two parts:
…
The HYDROSPHERE_ID is the
Login Id
allocated by Hydrosphere in Section 13.3.1 above.
HYDROSPHERE_PARAMETERS determines how many values to send, up to 16 in the automatically generated
program. LoadHydrosphere is where the variable names are assigned to be copied into the Hydrosphere data
message. Each variable is passed by address, and must be preceded by an @ symbol as shown above. Any public or
internal variable defined in the program may be mapped to Hydrosphere by using the name. If the name is misspelt
the program may still compile.