6.9.5 Assembly references
6.9.5.1 Ordering parts
The pumps covered by this manual have been designed and built with certain
replaceable wearing parts. The recommended inventory of spare parts depends upon the
installation and the importance of continued operation.
For critical service requiring a minimum of “down time” a complete or “quick change”
rotating element is recommended.
For normal service, with repairs to be made in the field, the following parts are
recommended for stock.
• 1 set of bearings
• 1 set of wearing rings
• 1 set of gaskets, O-rings, and grease seals
• 2 mechanical seals (complete), or 2 sets of packing (if provided)
• 1 set of shaft sleeves
Parts should be ordered as far in advance of their use as possible since circumstances
beyond the control of the company may reduce existing stock. Not all parts are stocked
and must be manufactured for each order.
To facilitate rapid handling of your order for spare parts, be sure to include the following
information:
1. Serial number of the pump.
2. Catalog number of the part.
3. Quantity of each part.
4. Name of the part.
5. Material desired. (Parts will be furnished in original materials unless specified as a
material change. All material substitutions should be discussed with the factory.
6.9.5.2 Screw torque values
Capscrew torque in ft-lb (Nm)
Capscrew
type
Head
marking
Capscrew diameter (in inches)
1/4
5/16
3/8
7/16
1/2
5/8
3/4
7/8
1
SAE grade
2
6 (8)
13 (18)
25 (34)
38 (52)
60 (81)
120 (163) 190 (258) 210 (285) 300 (407)
Brass and
stainless
steel
or
4 (5)
10 (14)
17 (23)
27 (37)
42 (57)
83 (113)
130 (176) 200 (271) 300 (407)
SAE grade
5
10 (14)
20 (27)
35 (47)
60 (81)
90 (122)
180 (244) 325 (440) 525 (712) 800 (1085)
*The M6 set screw has a rating of 10 N m.
6.9.5.3 Dealer servicing
If trouble occurs that cannot be rectified, contact your local sales and service
representative and be prepared to provide this information:
1. Complete nameplate data of pump and motor
2. Suction and discharge pipe pressure gauge readings
3. Ampere draw of the motor
4. A sketch of the pump hook-up and piping
6 Maintenance
50
G&L Pumps Series A-C 8100 Base Mounted Centrifugal Pump INSTRUCTION MANUAL