background image

ELECTRICAL

The electrical wiring should be independent of all other

accessories. It should be made with marine grade cop-

per stranded wire of the gauge specified in the electrical

specifications  chart.  Make  all  wire  connections  with

mechanical  locking  type  connectors  (crimp  type  butt

connectors and terminals). Ensure the circuit is protect-

ed by a proper sized fuse or circuit breaker determined

from the electrical specifications chart. Secure all wires

to a solid surface approximately every eighteen inches

(1/2 M) along their entire length of run.
Wire  the  switch  panel  to  the  solenoid  valve/siphon

breaker and toilet pump assembly as per the following

wiring  diagram.  Select  a  location  for  the  switch  panel

that  is  convenient  to  the  toilet  user  and  that  will  also

allow access to run the wires from the switch panel to

both  the  toilet’s  motor  and  the  solenoid  valve/siphon

breaker as well as from the electrical power source to

the switch panel. Connect the brown lead from the panel

to  the  waste  pump  positive  (orange)  motor  lead.

Connect  the  black  waste  pump  motor  lead  to  battery

negative.  Connect  the  yellow  lead  from  the  panel  to  a

solenoid valve terminal. Connect the remaining solenoid

valve terminal to battery negative. The valve solenoid is

not polarity sensitive.

To install the switch panel, drill two 1-3/4

"

(45 mm) diam-

eter  holes  (slightly  over-lapping)  through  the  selected

switch  mounting  surface  per  the  attached  template.

Ensure  the  template  is  oriented  correctly  because  it  is

not symmetrical.  Also, drill four appropriate sized holes

for the fasteners selected to secure the switch panel to

its mounting surface.

ELECTRICAL SPECIFICATIONS

AMP       FUSE        

WIRE SIZE PER FEET OF RUN*

VOLTAGE  DRAW       SIZE    0'-10' (0 M-3 M)   10'-15' (3 M-4,6 M)

12 Vdc 

10              25

#16 (1,5 mm

2

)            #14 (2,5 mm

2

)

24 Vdc

5               15

#16 (1,5 mm

2

)            #16 (1,5 mm

2

)

1-3/4" (45 mm) DIA

1-3/4" (45 mm) DIA

UP

TEMPLATE

BROWN

RED

YELLOW

YELLOW

BROWN

YELLOW

BROWN

RED

RED

RED

WIRING DIAGRAM

To Waste
Pump
Positive
(Orange)
Motor Lead

To Solenoid
Valve/Siphon
Breaker

To 
Positive

4

WIRE SIZE PER FEET OF RUN*

15'-25' (4,6 M-7,6 M)

25'-40' (7,6 M-12,2 M)     40'-60' (12,2 M-18,3 M)

#12 (4 mm

2

)          

#10 (6 mm

2

)

#8 (10 mm

2

)

#16 (1,5 mm

2

)

#14 (2,5 mm

2

)                       #12 (4 mm

2

)

* Length of run is total distance from power source to product and back to ground.

TEMPLATE

WIRING DIAGRAM

Summary of Contents for JABSCO 37075 Series

Page 1: ...rmal Water 1 2 Quarts Litres Flush Consumption OPERATION The Designer Styled Toilet with the popular Quiet Flush system provide both quiet operation and user control of water levels in the toilet bowl...

Page 2: ...bly If the toilet is being con nected to the vessel s fresh water system and the vessel may be connected to an unregulated city water supply it is recommended that a valve be installed in the toilet w...

Page 3: ...prior to fastening it to its mount ing surface Once the electrical wiring is complete test the toilet by flushing several times and blot all hose ter mination s completely around each connection with...

Page 4: ...r lead Connect the black waste pump motor lead to battery negative Connect the yellow lead from the panel to a solenoid valve terminal Connect the remaining solenoid valve terminal to battery negative...

Page 5: ...the two seal wash ers from under the head of each of the two seal housing retainer screws With a pair of needle nose pliers grasp the shaft seal and pull it from the seal housing Clean all parts and...

Page 6: ...h Lock n ut 1 37056 1000 12 Macerator Housing 1 37014 0000 13 Centrifugal Impeller 1 37006 0000 14 Set Screw 1 18753 0492 15 O ring 1 43990 0066 Qty Part Key Description Req Number 16 Seal 1 1040 0000...

Page 7: ...254 16 3 4 425 8 1 2 216 13 1 2 343 DIMENSIONAL DRAWINGS Inches Millimeters Compact Size Bowl Standard Size Bowl A 19 3 16 487 19 3 16 487 B 15 1 2 394 15 1 2 394 C 14 1 4 362 17 1 4 438 D 8 7 8 225 8...

Page 8: ...ED THE COn TRACT PRICE FOR THE PRODUCT CLAIMED TO BE DEFECTIVE OR Un SUITABLE 4 This warranty does not extend to any product manu factured by JABSCO which has been subjected to misuse neglect accident...

Reviews: