background image

23

TECHNICAL APPENDIX

113

TECHNICAL APPENDIX

t

T

ps

ρ

ρ

ρ

t

T

ps

t

T

ps

°

C

K

bar

kg/dm

3

°

C

K

bar

kg/dm

3

°

C

K

bar

kg/dm

3

0

273,15

0,00611

0,9998

55

328,15

0,15741

0,9857

120

393,15

1,9854

0,9429

1

274,15

0,00657

0,9999

56

329,15

0,16511

0,9852

122

395,15

2,1145

0,9412

2

275,15

0,00706

0,9999

57

330,15

0,17313

0,9846

124

397,15

2,2504

0,9396

3

276,15

0,00758

0,9999

58

331,15

0,18147

0,9842

126

399,15

2,3933

0,9379

4

277,15

0,00813

1,0000

59

332,15

0,19016

0,9837

128

401,15

2,5435

0,9362

5

278,15

0,00872

1,0000

60

333,15

0,1992

0,9832

130

403,15

2,7013

0,9346

6

279,15

0,00935

1,0000

61

334,15

0,2086

0,9826

132

405,15

2,867

0,9328

7

280,15

0,01001

0,9999

62

335,15

0,2184

0,9821

134

407,15

3,041

0,9311

8

281,15

0,01072

0,9999

63

336,15

0,2286

0,9816

136

409,15

3,223

0,9294

9

282,15

0,01147

0,9998

64

337,15

0,2391

0,9811

138

411,15

3,414

0,9276

10

283,15

0,01227

0,9997

65

338,15

0,2501

0,9805

140

413,15

3,614

0,9258

11

284,15

0,01312

0,9997

66

339,15

0,2615

0,9799

145

418,15

4,155

0,9214

12

285,15

0,01401

0,9996

67

340,15

0,2733

0,9793

155

428,15

5,433

0,9121

13

286,15

0,01497

0,9994

68

341,15

0,2856

0,9788

160

433,15

6,181

0,9073

14

287,15

0,01597

0,9993

69

342,15

0,2984

0,9782

165

438,15

7,008

0,9024

15

288,15

0,01704

0,9992

70

343,15

0,3116

0,9777

170

433,15

7,920

0,8973

16

289,15

0,01817

0,9990

71

344,15

0,3253

0,9770

175

448,15

8,924

0,8921

17

290,15

0,01936

0,9988

72

345,15

0,3396

0,9765

180

453,15

10,027

0,8869

18

291,15

0,02062

0,9987

73

346,15

0,3543

0,9760

185

458,15

11,233

0,8815

19

292,15

0,02196

0,9985

74

347,15

0,3696

0,9753

190

463,15

12,551

0,8760

20

293,15

0,02337

0,9983

75

348,15

0,3855

0,9748

195

468,15

13,987

0,8704

21

294,15

0,24850

0,9981

76

349,15

0,4019

0,9741

200

473,15

15,550

0,8647

22

295,15

0,02642

0,9978

77

350,15

0,4189

0,9735

205

478,15

17,243

0,8588

23

296,15

0,02808

0,9976

78

351,15

0,4365

0,9729

210

483,15

19,077

0,8528

24

297,15

0,02982

0,9974

79

352,15

0,4547

0,9723

215

488,15

21,060

0,8467

25

298,15

0,03166

0,9971

80

353,15

0,4736

0,9716

220

493,15

23,198

0,8403

26

299,15

0,03360

0,9968

81

354,15

0,4931

0,9710

225

498,15

25,501

0,8339

27

300,15

0,03564

0,9966

82

355,15

0,5133

0,9704

230

503,15

27,976

0,8273

28

301,15

0,03778

0,9963

83

356,15

0,5342

0,9697

235

508,15

30,632

0,8205

29

302,15

0,04004

0,9960

84

357,15

0,5557

0,9691

240

513,15

33,478

0,8136

30

303,15

0,04241

0,9957

85

358,15

0,5780

0,9684

245

518,15

36,523

0,8065

31

304,15

0,04491

0,9954

86

359,15

0,6011

0,9678

250

523,15

39,776

0,7992

32

305,15

0,04753

0,9951

87

360,15

0,6249

0,9671

255

528,15

43,246

0,7916

33

306,15

0,05029

0,9947

88

361,15

0,6495

0,9665

260

533,15

46,943

0,7839

34

307,15

0,05318

0,9944

89

362,15

0,6749

0,9658

265

538,15

50,877

0,7759

35

308,15

0,05622

0,9940

90

363,15

0,7011

0,9652

270

543,15

55,058

0,7678

36

309,15

0,05940

0,9937

91

364,15

0,7281

0,9644

275

548,15

59,496

0,7593

37

310,15

0,06274

0,9933

92

365,15

0,7561

0,9638

280

553,15

64,202

0,7505

38

311,15

0,06624

0,9930

93

366,15

0,7849

0,9630

285

558,15

69,186

0,7415

39

312,15

0,06991

0,9927

94

367,15

0,8146

0,9624

290

563,15

74,461

0,7321

40

313,15

0,07375

0,9923

95

368,15

0,8453

0,9616

295

568,15

80,037

0,7223

41

314,15

0,07777

0,9919

96

369,15

0,8769

0,9610

300

573,15

85,927

0,7122

42

315,15

0,08198

0,9915

97

370,15

0,9094

0,9602

305

578,15

92,144

0,7017

43

316,15

0,09639

0,9911

98

371,15

0,9430

0,9596

310

583,15

98,70

0,6906

44

317,15

0,09100

0,9907

99

372,15

0,9776

0,9586

315

588,15

105,61

0,6791

45

318,15

0,09582

0,9902

100

373,15

1,0133

0,9581

320

593,15

112,89

0,6669

46

319,15

0,10086

0,9898

102

375,15

1,0878

0,9567

325

598,15

120,56

0,6541

47

320,15

0,10612

0,9894

104

377,15

1,1668

0,9552

330

603,15

128,63

0,6404

48

321,15

0,11162

0,9889

106

379,15

1,2504

0,9537

340

613,15

146,05

0,6102

49

322,15

0,11736

0,9884

108

381,15

1,3390

0,9522

350

623,15

165,35

0,5743

50

323,15

0,12335

0,9880

110

383,15

1,4327

0,9507

360

633,15

186,75

0,5275

51

324,15

0,12961

0,9876

112

385,15

1,5316

0,9491

370

643,15

210,54

0,4518

52

325,15

0,13613

0,9871

114

387,15

1,6362

0,9476

374,15

647,30

   

221,20

0,3154

53

326,15

0,14293

0,9862

116

389,15

1,7465

0,9460

54

327,15

0,15002

0,9862

118

391,15

1,8628

0,9445

G-at_npsh_a_sc

TECHNICAL APPENDIX VAPOUR PRESSURE PS VAPOUR

PRESSURE AND

ρ

DENSITY OF WATER TABLE

TECHNICAL APPENDIX VAPOUR PRESSURE 

VAPOUR PRESSURE ps AND

 ρ 

DENSITY OF WATER TABLE

Summary of Contents for Lowara Scuba SC205C

Page 1: ...Cod 191005661 Rev A Ed 06 2017 50 Hz SCUBA Series CLOSE COUPLED SUBMERSIBLE ELECTRIC PUMPS ...

Page 2: ......

Page 3: ...3 CONTENTS Specifications 5 Identification code and rating plate 8 Hydraulic performance range 9 Dimensions and weights 10 Motor control panel combination table 12 Technical appendix 13 ...

Page 4: ... 15 25 35 45 55 65 75 20 30 40 50 60 70 80 Q US gpm 4 6 8 12 14 16 18 22 24 26 28 32 34 10 20 30 H ft 60 80 120 140 160 180 220 240 260 100 200 Q l min 22 1 27 7 38 7 44 3 55 3 60 9 71 9 77 5 88 5 94 1 105 1 110 7 121 7 127 3 17 33 50 66 83 100 116 133 Q Imp gpm 3 4 6 7 8 9 11 12 13 14 16 17 18 19 21 22 23 24 26 27 28 29 5 10 15 20 25 ...

Page 5: ...es 2850 rpm overload protection to be provided by user and installed in the control panel see electric panel section Maximum supply voltage variations 5 Classe F insulation Can also operate in horizontal position Maximum number of starts per hour evenly distributed 25 for motors up to 0 9 kW 20 for motors 1 1 kW Maximum temperature of water in contact with the motor 40 C continuos use CONTRUCTION ...

Page 6: ...6 SCUBA SERIES PUMP SECTION AND LIST OF MAIN COMPONENTS 04453B_C_DS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 15 17 17 17 17 17 18 17 19 20 24 21 23 22 25 26 ...

Page 7: ... 1 X5CrNi18 10 1 4301 AISI 304 12 Upper head Tecnopolymer PPS 13 Bearing support upper Stainless steel EN 10088 1 X5CrNi18 10 1 4301 AISI 304 14 Complete falnge 15 Filter Stainless steel EN 10088 1 X5CrNi18 10 1 4301 AISI 304 16 Connection container 17 Elastomers Nitrile rubber NBR 18 External mechanical seal Silicon carbide 19 Bush bearing Tecnopolymer PU 20 Internal mechanical seal fixed part St...

Page 8: ...27 SC SCUBA series pump 2 Flow rate 2 m3 h 07 Motor power 0 75 kW Null 50 Hz Null Single phase C With capacitor G Float L27 20 m cable H07 Cable L27 20 m cable H07 Power supply M Single phase T Three phase 04466_C_SC 04467_C_SC SINGLE PHASE RATING PLATE THREE PHASE RATING PLATE LEGEND 1 Electric pump type 2 Code 3 Delivery range 4 Head range 5 Characteristics motor 6 Manufacturing data and serial ...

Page 9: ... AT 50 Hz 2 3 4 5 6 7 8 1 H m 20 30 40 50 60 70 80 10 5 6 7 8 9 20 30 10 H ft 40 50 60 70 80 90 200 100 4 5 6 7 8 9 20 10 20 30 40 50 60 70 80 90 100 SC2 SC4 ISO 9906 2012 Grade 3B Q Imp gpm 2850 rpm 04456_C_CH Q l min Q m 3 h SC2 SC4 Q US gpm ...

Page 10: ...09T 0 9 1 2 72 4 66 3 61 8 56 3 49 6 41 8 27 4 SC211C SC211T 1 1 1 5 84 5 77 6 72 6 66 3 58 6 49 2 31 7 SC407C SC407T 0 75 1 49 4 42 8 40 6 38 1 34 0 32 5 25 9 16 5 SC409C SC409T 0 9 1 2 62 5 52 3 49 6 46 7 41 8 40 1 32 2 19 9 SC411C SC411T 1 1 1 5 75 5 63 4 60 0 56 4 50 6 48 5 39 3 25 4 scuba sc2 sc4 2p50 en_c_th RATED POWER Q DELIVERY H TOTAL HEAD METRES COLUMN OF WATER DATI ELETTRICI SERIE SCUB...

Page 11: ...viscosity ν 1 mm2 sec SC2 SC4 2850 rpm ISO 9906 2012 Grade 3B 0 5 10 15 20 25 30 0 20 40 60 80 100 120 140 Q Imp gpm Q l min SC411 SC409 SC407 SC211 SC209 SC207 SC205 0 5 10 15 20 25 30 35 0 50 100 150 200 250 0 10 20 30 40 50 60 70 80 90 Q US gpm H ft H m 30 40 50 60 0 1 2 3 4 5 6 7 8 9 η Q m3 h η η η ηpSC2 η η η ηpSC4 04451A_E_CH ...

Page 12: ...C205T 0 55 0 75 1 62 11 05 SC207T 0 75 1 2 38 11 11 SC209T 0 9 1 2 2 54 15 11 SC211T 1 1 1 5 2 70 15 11 SC407T 0 75 1 2 40 11 11 SC409T 0 9 1 2 2 60 15 11 SC411T 1 1 1 5 2 85 15 11 Maximum values within operating range scuba sc2 sc4 2p50 en_b_tp For different voltage e g 220 240 V please contact our network POWER RATED PANEL TYPE ...

Page 13: ...13 TECHNICAL APPENDIX ...

Page 14: ...ch and thermal relay for overload protection Non return valve at 10 meters distance from the delivery ports plus an additional non return valve every 30 50 meters of piping Gauge and gate valve at well mouth Electronic probes or floats for protection against dry running Secure the drop cable to the pipe every 2 3 meters of piping Make sure the electric pump is installed at a safe distance from the...

Page 15: ...acket 6 Delivery pipe 7 Electrical cable for motor power 8 Electric pump bleed priming cap 9 Pressure gauge 10 Diaphragm tank 11 Gate valve 12 Control panel 13 PTC PT100 cable 14 Pressure transducer 15 Inverter Hydrovar or ResiBoost 16 Filter suggest for cable lenghts exceeding 20 meters N B For correct Inverter Motor coupling contact our sales network A0034_B_SC 16 7 9 4 2 3 1 4 15 5 8 10 12 2 2 ...

Page 16: ...16 SCUBA 50 Hz SIZING OF ETHYLENE PROPILENE EPR CABLES DOL DIRECT ON LINE STARTING ϕ ϕ ϕ ϕ ϕ ϕ ϕ ϕ TECHNICAL APPENDIX ...

Page 17: ...er d 0 144 m operates in an 8 well well diameter D 0 203 m with flow rate Q 20 m3 h 0 0055 m3 s Speed of fluid v 0 0055 2 π 0 203 2 4 0 144 2 4 0 17 m s The minimum speed required for proper motor cooling is vm 0 20 m s Because v vm it will be necessary to mount a cooling sleeve The following formula is used to determine the maximum diameter of a cooling sleeve to be mounted on a submersible motor...

Page 18: ...is 70 the value of the line voltage The switch to the rated voltage occurs without any interruptions of the power supply Rated voltage Un 400 V Starting current Us Is In x 4 8 x In x 3 6 Un Starting torque Us Ts Tn x 2 3 x 2 Tn x 1 1 5 Un ASYNCHRONOUS MOTOR STARTING SYSTEMS Ia TECHNICAL APPENDIX Direct Suitable for low power motors The starting current Is is much higher than the rated current In S...

Page 19: ... bathroom and flush tank WC Coefficient for apartments with one bathroom and controlled flushing system WC Coefficient for apartments with two bathrooms and flush tank WC Coefficient for apartments with two bathrooms and controlled flushing system WC f coefficient Nr number of delivery points Na number of apartments WATER REQUIREMENTS IN CIVIL USERS Determination of the water requirement depends o...

Page 20: ...302 394 26 162 202 308 401 27 165 205 314 409 28 168 209 320 417 29 171 213 325 424 30 174 217 331 431 35 187 234 357 466 40 200 250 382 498 45 213 265 405 528 50 224 280 427 557 55 235 293 448 584 60 245 306 468 610 65 255 319 487 635 70 265 331 506 659 75 274 342 523 682 80 283 354 540 704 85 292 364 557 726 90 301 375 573 747 95 309 385 589 767 100 317 395 604 787 120 347 433 662 863 140 375 46...

Page 21: ...località balneari maggiorare la portata almeno del 20 1 Uffici Nr di persone 2 Grandi magazzini Nr di persone 3 Case di cura Nr di posti letto 4 Hotel Residence Nr di posti letto The requirements of buildings intended for specific uses such as offices residential units hotels department stores nursing homes and so on are different from those of condominiums and both their global daily water consum...

Page 22: ...en the pump axis and the free liquid surface in the suction tank expressed in m hz is negative when the liquid level is lower than the pump axis hf is the flow resistance in the suction line and its accessories such as fittings foot valve gate valve elbows etc hpv is the vapour pressure of the liquid at the operating temperature expressed in m of liquid hpv is the quotient between the Pv vapour pr...

Page 23: ...5 0 4931 0 9710 225 498 15 25 501 0 8339 27 300 15 0 03564 0 9966 82 355 15 0 5133 0 9704 230 503 15 27 976 0 8273 28 301 15 0 03778 0 9963 83 356 15 0 5342 0 9697 235 508 15 30 632 0 8205 29 302 15 0 04004 0 9960 84 357 15 0 5557 0 9691 240 513 15 33 478 0 8136 30 303 15 0 04241 0 9957 85 358 15 0 5780 0 9684 245 518 15 36 523 0 8065 31 304 15 0 04491 0 9954 86 359 15 0 6011 0 9678 250 523 15 39 ...

Page 24: ... hr 187 63 2 17 6 6 41 2 16 0 73 0 30 v 5 10 3 02 1 99 1 27 0 82 0 57 0 42 hr 88 6 24 7 8 98 3 03 1 02 0 42 0 20 v 5 94 3 52 2 32 1 49 0 95 0 66 0 49 hr 118 32 8 11 9 4 03 1 36 0 56 0 26 v 6 79 4 02 2 65 1 70 1 09 0 75 0 55 hr 151 42 0 15 3 5 16 1 74 0 72 0 34 v 7 64 4 52 2 99 1 91 1 22 0 85 0 62 hr 188 52 3 19 0 6 41 2 16 0 89 0 42 v 5 03 3 32 2 12 1 36 0 94 0 69 0 53 hr 63 5 23 1 7 79 2 63 1 08 ...

Page 25: ...2 4 2 8 90 bend 0 4 0 6 0 9 1 1 1 3 1 5 2 1 2 6 3 0 3 9 4 7 5 8 90 smooth bend 0 4 0 4 0 4 0 6 0 9 1 1 1 3 1 7 1 9 2 8 3 4 3 9 Union tee or cross 1 1 1 3 1 7 2 1 2 6 3 2 4 3 5 3 6 4 7 5 10 7 12 8 Gate 0 2 0 2 0 2 0 4 0 4 0 6 0 9 1 1 1 3 Non return valve 1 1 1 5 1 9 2 4 3 0 3 4 4 7 5 9 7 4 9 6 11 8 13 9 G a pcv_a_th DN Equivalent pipeline length m TABLE OF FLOW RESISTANCE IN BENDS VALVES AND GATES ...

Page 26: ...8067 0 0981 1 4223 1 0000 73 5561 133 3220 0 1333 0 0013 0 0193 0 0136 1 0000 Millimetre Centimetre Metre Inch Foot Yard mm cm m in ft yd 1 0000 0 1000 0 0010 0 0394 0 0033 0 0011 10 0000 1 0000 0 0100 0 3937 0 0328 0 0109 1 000 0000 100 0000 1 0000 39 3701 3 2808 1 0936 25 4000 2 5400 0 0254 1 0000 0 0833 0 0278 304 8000 30 4800 0 3048 12 0000 1 0000 0 3333 914 4000 91 4400 0 9144 36 0000 3 0000 ...

Page 27: ... products and accessories The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara and Vogel products The search can be made by Application Product type Duty point Xylect gives a detailed output List with search results Performance curves flow head power efficiency NPSH Motor d...

Page 28: ... possible to Set own standard units Create and save projects Share projects with other Xylect users Every registered user has a proper space where all projects are saved For more information about Xylect please contact our sales network or visit www xylect com Dimensional drawings appear on the screen and can be downloaded in dxf format FURTHER PRODUCT SELECTION AND DOCUMENTATION XylectTM ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ......

Page 32: ...ies that will improve the way water is used conserved and reused in the future is central to our work Our products and services move treat analyze monitor and return water to the environment in public utility industrial residential and commercial building services and agricultural settings With its October 2016 acquisition of Sensus Xylem added smart metering network technologies and advanced data...