Question: Which size MagFlux® flow meter should I choose for my
installation? I would prefer a flow meter with the same diameter as the
tube(s).
Answer: The minimum and maximum flows determine the size. Use the
to find the correct flow meter size, and avoid selecting a too
large size.
Question: Where do I install the MagFlux® flow meter in relation to valves,
bends, pumps, etc.?
Answer: Minimum three times the MagFlux® flow meter's internal diameter
(DN) up-stream, and minimum two times its internal diameter (DN) down-
stream.
Question: Must the tube be completely filled with liquid to perform
reliable flow measurements?
Answer: Yes. Always ensure a filled tube.
Question: Do I need a separate display unit for each sensor?
Answer: No. A display unit can manage up to four converters.
Question: Is the analogue mA output an active output?
Answer: Yes, it is.
Question: The tubes are made of plastic. Do I need grounding rings?
Answer: We recommend that you always use two grounding rings.
Furthermore, see
Potential equalization and grounding
Question: Are the relays potential-free?
Answer: Yes, they are.
Question: Does the sensor/flow meter comply with IP68?
Answer: It will once you employ a wall mounting kit, a special cable and a gel
potting kit to protect the electrical connections.
Question: Can I use a MagFlux® flow meter to measure non-conductive
liquids such as diesel oil?
Answer: No. The electromagnetic principle presupposes conductivity. The
conductivity limit is 5 µS/cm.
Summary of Contents for MJK MagFlux Series
Page 1: ...Manual EN 3 05 Version 2102 MagFlux Series ELECTROMAGNETIC FLOWMETER ...
Page 2: ...MagFlux Series EN 3 05 Version 2102 2 Your notes ...
Page 21: ...MagFlux Series EN 3 05 Version 2102 Flow sensor Sizing chart 21 ...
Page 22: ...MagFlux Series EN 3 05 Version 2102 Flow sensor Sizing chart 22 ...
Page 59: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Specify main screen 59 ...
Page 60: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Specify main screen 60 ...
Page 87: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Converter setup 87 ...
Page 90: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Converter setup 90 ...
Page 104: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Converter setup 104 ...
Page 110: ...MagFlux Series EN 3 05 Version 2102 MagFlux menus Converter setup 110 ...
Page 156: ...MagFlux Series EN 3 05 Version 2102 Appendix F Log files MJK cut out download 156 ...
Page 165: ...MagFlux Series EN 3 05 Version 2102 Main menu overview Configuration for the slave unit 165 ...
Page 179: ......