8 Technical Specification
8.1 Dimensions
110.mm (4.4 in) x 99.2 mm (3.9 in) x 35.4 mm (1.4 in)
8.2 Approvals
Regulatory:
• FCC (US)
• ISED (Canada)
• CE (Europe)
• UKCA (United Kingdom)
Industry:
• PTCRB
• GCF
8.3 Environmental requirements
Gateway
Feature
Value
Operating location
Indoor use
Operating environment
Non-hazardous, non-corrosive
Operating temperature
-40°C to +80°C (-40°F to +176°F)
Storage temperature
-40°C to +85°C (-40°F to +185°F)
Operating humidity
10% to 95% non-condensing
Storage humidity
5% to 95% non-condensing
Power supply
Feature
Value
Operating location
Indoor use
Operating environment
Non-hazardous, non-corrosive
Operating temperature
0°C to +40°C (+32°F to +104°F)
Storage temperature
-20°C to +60°C (-4°F to +140°F)
Operating humidity
20- 85%, non-condensing
Storage humidity
5- 95%, non-condensing
8.4 Power
Input voltage of 5 V and 1.2 A (standard USB power).
AC line power requirements
• Voltage input: 90 VAC ~ 264 VAC
8.5 Wireless communication
Feature
Value
Bluetooth
Bluetooth Low Energy Secure Connections 4.2
Cellular
• Multi-Band cellular operation for world-wide operation
• Category LTE-M
8 Technical Specification
optimyze
™
Gateway Instruction, Operation, and Maintenance Manual
11