background image

 

6 / 25 

 

If it has to be assumed that safe operation is impossible, the meter has to be put out of operation 

and secured against inadvertent putting to operation!

 Switch the meter off, pull plug of the mains cable out 

of the power supply, and remove the meter from the place of work. 

Examples for the assumption that a safe operation is no longer possible, 

 

if the package is damaged, 

 

if the meter shows visible damages, 

 

if the power supply (VER05US050-JA) shows visible damages, 

 

if the meter does not function properly, 

 

if liquid has penetrated into the casing. 

 

if the meter has been altered technologically or if unauthorized personnel tried or succeeded 
to open the instrument as attempt to repair it. 
 

In case that the user operates such a device, all thereof resulting risks are on the user. 

 The meter must not be stored or operated in humid rooms. 

  The relevant regulations regarding the  handling of the substances used have to be observed: 

The Decree on Hazardous Matters, the Chemicals Act, and the rules and information of the chemicals trade. It 
has to be ensured on the side of the user that the persons entrusted with the use of the meter are experts in the 
handling of substances used in the environment and in titrator or that they are supervised by specialised 
persons, respectively.

 

 Use only the sensors, sensor cables and interface cables recommended by the manufacturer. The notes 

and statements in the respective user manuals and data sheets apply to the use of the sensors and fittings. 

 

The device does not contain any components that need to be replaced and must only be opened for repair 

by the manufacturer's technicians. 

If in doubt, please contact the supplier. 
 
 
 

Set up and Commissioning 

 

Scope of delivery 

2.1

The scope of delivery is shown on the included packing list. 

 There is a detailed list of the individual sets in 

 chapter „Scope of delivery” 

 Accessories can be found in 

 chapter „Accessories”

 

 
 

 

Unpacking and Setup 

2.2

The meter and all accessories were carefully inspected for function and size accuracy at the factory. 
Please make sure that you also remove all of the small additional parts from the packaging. 
 
The meter can be set up on any even surface. 
 

 The safety of the system, in which the device will be integrated, is the responsibility of the installer. 

 

 If the meter is transported from a cold into a warm environment, there can be malfunctions in the device 

caused by condensate. In this case, you have to wait until the device temperature and the room temperature 
have reached a balance before you start the meter. 
 

 The flawless function and operational safety of the meter can only be warranted under those climate 

conditions specified in 

 chapter „Specifications”. 

 
 

 

Power supply 

2.3

The meter is delivered ready to operate with a 5 V DC power supply. 
 

Summary of Contents for PTM40

Page 1: ...2018 03 14 Operating Manual PTM40 PLF40 pH ORP ISE conductivity meter...

Page 2: ...User qualification 4 1 2 Specifications 4 1 3 Warning and safety information 5 1 4 2 Set up and Commissioning 6 Scope of delivery 6 2 1 Unpacking and Setup 6 2 2 Power supply 6 2 3 3 Device descriptio...

Page 3: ...eturns 25 Notes about Instructions for Use These instructions for use are intended to show you the proper and safe handling of the product For the highest possible safety you must adhere to the listed...

Page 4: ...ntion and handling of chemicals are adhered to Please observe the general see chapter 1 4 and all in the text additionally placed warnings and safety notes Specifications 1 3 Translation of the legall...

Page 5: ...rature compensation cable offset TDS factor Temperature offset One point Automatic Warning and safety information 1 4 The meter PTM40 PLF40 has the protection class III It was manufactured and tested...

Page 6: ...Use only the sensors sensor cables and interface cables recommended by the manufacturer The notes and statements in the respective user manuals and data sheets apply to the use of the sensors and fitt...

Page 7: ...f analysis parameters you must keep in mind that the sensors must be calibrated and maintained regularly The measuring input must be free of potentials and must not be connected to power conducting po...

Page 8: ...t Measuring mode Cursor right Change enter values Position value 1 Position value 1 Save confirm value Cursor left Measuring mode Cursor right The meter is turned on by pressing ON OFF Switching off t...

Page 9: ...9 25 4 Temperature 5 Min main measured values 6 Max main measured values 7 Time 8 Date 9 Secondary measured value Menu structure 3 4...

Page 10: ...ly in chapter 3 4 Under General the following device relevant basic settings can be configured Display backlight and contrast Password Password Clock Clock Reset Restart device Language Language Time...

Page 11: ...e value Configuration of the switch off time 4 5 You can set the time on the meter after which the meter will be switched off automatically The data logger also records while the meter is off if the d...

Page 12: ...ogs with the device switched on or off at the same time the power supply connected The correct setting of the real time clock is required for the proper function of the data logger During the reading...

Page 13: ...clically output via the serial interface as ASCII characters Use only interface cable Interface HMG USB to transfer data from the meter to the PC This cable is not included in the delivery and must be...

Page 14: ...accessories and the pH sensor EGA142 K010 U X This combination meets the requirements to determine the pH value electro chemical process as per EN ISO 10523 2012 The meter can be used wherever you wan...

Page 15: ...he temperature of the measuring and calibration media must be measured or set up as a fixed temperature If the fixed temperature is activated it is used for temperature compensation The message FIX wi...

Page 16: ...ich the settings should be changed Asymmetry Steepness An input dialog will allow you to change the respective calibration sensor values and their respective limits If these are not reached or exceede...

Page 17: ...ompted to immerse the sensor into the third calibration medium Perform the same steps as with the first calibration solution 8 4 2 5 Automatic calibration Two and Three point The automatic calibration...

Page 18: ...horoughly cleaned with distilled or deionized water prior to and between every measurement Immerse the sensor into the calibration solution and wait until a stable measured value is reached Ensure tha...

Page 19: ...e submenu item for which the settings should be changed Asymmetry measured value 1 input value 1 An input dialog will allow you to change the respective calibration sensor values and their respective...

Page 20: ...electro chemical process as per EN 27888 1993 When connected to the sensor the meter will capture the conductivity in S or mS the temperature as well as the salinity simultaneously All Meinsberg Cond...

Page 21: ...ally selects the suitable measuring range TDS 5 shows the TDS value as a secondary variable Resist 5 shows the resistance value as a secondary variable 1 Measuring range switching possible 2 Measuring...

Page 22: ...ompensation with adjustable temperature coefficient nLF non linear temperature compensation for natural waters as per DIN EN 27888 out For measurements without temperature compensation the temperature...

Page 23: ...will be displayed Incorrect entry or Calibration error You may have to repeat the calibration service the sensor or replace it wear part 10 Scope of delivery PTM40 Set Lab pH meter Power supply Tripod...

Page 24: ...roper handling use or illegitimate opening of the device results in loss of the guarantee rights The guarantee does not cover wear parts The breach of glass parts is also excluded To ascertain the gua...

Page 25: ...GmbH Dr Karl Slevogt Stra e 1 D 82362 Weilheim Germany Service and Returns Xylem Analytics Germany Sales GmbH Co KG Sensortechnik Meinsberg Meinsberg Kurt Schwabe Stra e 6 D 04736 Waldheim Germany Te...

Reviews: