Installation
Just before mounting the HRI-Mei on the meter 
it is essential to remove the aluminium foil at the 
bottom side!

Installation (see image 

1

)

1.  Open the cover for OD with slight pressure 

against the left side.

2.  Turn blue ring counterclockwise against stop 

(ca. 10°); pulse sensor slots are open.

3.  Insert the two hooks of the HRI-Mei diagonally 

from above into the holes of the backfitting ring.

4.  Push HRI-Mei down until it is fixed on the 

backfitting ring.

5.  Turn blue ring clockwise against stop (ca. 10°); 

pulse sensor slots are barred.

6.  Close cover for OD. If required the HRI-Mei can 

be protected with a seal wire against removal.

7.  Release the round cover from the hinge and 

replace it with the supplied semicircular cover.

Type

HRI-Mei provides 7 different pulse modes each with 
the following pulse weights
D = 10 / 50 / 100 / 250 / 500 or 1000 litres/pulse 
Pulse length T= 32, 128 or 500 ms (not with B5, B6)

Pulse 
mode

Wire

l1 (white)

l2 (yellow)

B1

Balanced pulses** Tamper = closed

B2

Forward pulses

Backward pulses

B3

Forwards and
backwards pulses

Direction signal
forward = open

B4

Balanced pulses** Tamper = open

B5

NAMUR with for-
ward / backward 
signal

Not used

B6

NAMUR with
suppressing back-
ward flow 
(“OD-AM”)

Not used

B7

Balanced pulses

Balanced pulses

Ground (grey)
**) 

Balanced pulses: Reverse volume must be 

compensated by identical forward volume before 
more pulses are output. That means, no output 
pulses during this period even though the meter 
register is counting forward.

DATA (green/brown) Also used for external power 
supply

Battery or external supply

Battery: 3.6V Lithium. Integral battery, not 
replaceable.

Durability

•  20 °C medium temperature: up to 12 years
•  12hrs 20 °C / 12 hrs 60 °C: up to 10 years

With a continuous external power supply of 10 V 
DC (max. 42 V DC) the durability increases to more 
than 15 years. In case of a voltage breakdown 
the battery of the module takes over the power 
supply. Therefore the stored values are not lost 
and the module continues the volume detection 
autonomously. The external supply can also be 
provided via an M-Bus system.

Technical Data

•  Environmental temperature range:  

-10 °C ... +60 °C

•  Cable length: 3 m
•  Protection class IP 68
•  EMC acc. EC98/34 (EN 61000-6-2 and EN 61000-

6-3)

Output pulses (I1/I2) for Mode B1 to B4 and B7

Open Collector pulse output module acc. ISO/TC30

Maximum voltage: 48 V DC / Imax: 200mA/ Pmax: 
4 W

Maximum residual voltage (output interconnected, 
-20 °C / +60 °C): 0,45 V@ 5 μA/ 0,55 V @5 mA/ 1,4 V 
@200 mA
Pulse width (32, 128 or 500 ms) adjustable

Flow direction in Mode B3: Signal I2 is active low = 
200 μs prior to first pulse in reverse direction.

Acceptable cable extension: depending on cable 
type and connected devices; several kilometres 
possible.

Transient voltage protection is highly recommended 
for wiring outside buildings.

Output pulses (I1) for Mode B5 and B6 (NAMUR-
compatible)

Acc. EN 60947-5-6 with constant pulse width from 
6ms resp. 7ms.

Transient voltage protection is highly recommended 
for wiring outside buildings.

Data interface

M-Bus and MiniBus (Auto speed detection: 300 / 
2400 Baud)

Protocol acc. EN13757-3 conforms IEC 870 / EN 1434

The data interface is NOT galvanically isolated 
from the grey connection lead, see connection 
diagram 

2

. This is to be considered when used 

simultaneously.

Data: Meter number and counter reading, monthly 
meter readings, min./max. flow rate and backflow 
with date and time, etc.

Tamper and alarm settings (s.a. MiniCom)

Cable extension: acc. M-Bus specification.

The quantity/number of readouts with M-Bus is 
unlimited. If MiniBus is used, do not readout more 
than hourly so that the battery life of 12 years is 
maintained.

With the data interface the following values can 
be adjusted with the help of the MiniCom software 
(Version > 3.6.40). (Default settings in brackets):

•  Primary address (0)
•  Secondary address (Fab.no. of HRI-Mei)
•  Meter no. (Fab.no. of HRI-Mei)
•  Counter reading (0); when the aluminum foil is 

missing the counter reading can be <> 0.

•  Day of month for monthly value storage (1).
•  Operator password = 00000001
•  Pulse mode, pulse value, pulse duration 

(depending on order)

Further settings s.a. MiniCom
Reading with the MiniReader (182080) is supported 
from firmware version >2.0.

If the HRI-Mei is ordered as a version mounted on 
a meter, the secondary address, meter number and 
the meter reading are pre-set with the ones from the 
mounted meter ex works.
The pulse value and the pulse period are set 
according to the order. An adjustment on-site is 
then not required.

When using M-Bus with separate delivered HRI-Mei, 
after mounting at a meter, the programming of the 
input pulse value and the alignment of the volume 
index has to be done.

Disposal

This product contains a lithium 
battery. In the interest of protecting 
the environment, this battery may 
not be disposed in household 
waste after its period of use. The 
local and national regulations for 
environmental protection are to be 
considered.

INSTALLATION AND OPERATING INSTRUCTIONS – HRI-Mei Bx

Data (green)

Data (brown)

Pulses l1 (white)

Pulses l2 (yellow)

Ground (grey)

1

Application examples

All connections with external power supply are optional. The 
HRI-Mei’s internal battery can also be used.

PLC with switched ground

HRI-Mei with external power supply

This application can be also used as a test tool 

for all HRI types 

PLC with switched power supply

Flow

Mode B1/4

Mode B2

Mode B3

open

open

open

open

open

close

close

close

close

close

forward

meter index

backwards

forward

forward

backward

EN DE FR ES

reverse

forward

white

white

white

yellow

green

grey

grey

green

e. g. Rx = 1 KOhm l = Ui/(Rx+Ri) = <200 mA

grey

Input

l1 balanced

l1 forward

l2 backwards

l1 forward & backwards

l2 Direction

2

HRI-Mei

B3

Reviews: