background image

Product description

:

Bulk meter for water up to 50 °C

Applications

Measurement of cold potable water up to 30 °C for billing applications
Measurement of clean water up to 50 °C
The normal flow rate should differentiate from the changeover flow rates. Frequent crossing of the changeover flow 

rates can shorten the service life. During operation a minimum upstream pressure of 0.5 bar must exist. With a lower 

pressure the safe switching of the valve is not ensured.

Included in the delivery

1 Water meter; 2 Gaskets; 1 Manual

Technical data

Refer to the technical data shees MeiTwin and MeiTwinRF (http://www.sensus.com)

Installation instructions
Safety tips

  

No mechanical stresses may be exerted on the meter when installed in the pipeline. The pipeline flanges must align 

with the  meter flanges and the distance between the flanges must match the meter body length. Misalignment stresses 

can cause the meter body or flanges to crack. When the pipeline is under pressure this can cause flooding.
The meter must not be subjected to pressures higher than the pressure rating printed on the meter. Too high pressure 

can cause leaks or burst the meter body. 

General instructions

The MeiTwin may only be installed by a trained and  instructed worker. Thereby the recognised 

standards of good practice have to be respected (We refer to the instructions given in ISO 4064-5:2014).
After the manufacturing process all meters are disinfected. The meters must be stored in a dry, cool, dust and germs 

free environment. Prior installation the meter must be disinfected again. Make sure that during the installation 

procedure all hygienic standards and recommendations are respected.

Installation Tools

Two spanners for the corresponding size of bolts used are necessary. Hoisting devices may be required, depending on 

the weight of the meter and the installation conditions. 

Installation instructions

The MeiTwin acc. to its approval does not need any straight upstream or downstream pipe (U0D0).
The maximum medium temperature shall not exceed 50 °C when in operation and 70 °C at down-time.
The environmental temperature must be within 5 and 70 °C.
The meters are classified acc. to 2014/32/EU (MID) in the mechanical environment class M2 (significant or high levels 

of vibration and shock) and in the electromagnetic environment class E2.
The  pipe diameter should not be abruptly reduced or expanded directly upstream or downstream the meter. All 

diameter changes should be done with an angle <8° related to the pipe centre.
All flow regulating devices (e.g. Valves, PRV’s) shall be installed downstream of the meter.
When selecting the  installation site, consider the meter orientation (horizontal/vertical)!
Gaskets must not protrude into the pipeline or be mis-aligned.
The pipeline must be thoroughly flushed before installing the meter to prevent damage from debris. 
The flow direction of the meter (arrow on the meter body) must correspond with the flow direction in the pipeline. 
After installation of the meter,  the pipeline must be filled  with water very slowly to prevent the meter being damaged 

by surges. In particular with the use of a piston type by-pass meter a moderate rotation speed of the sweep hands (<2/s) 

has to be maintained. Too fast evacuation will damage the by-pass meter.
The installation site should be selected to prevent air bubbles collecting in the meter and the pipeline must always be 

completely filled with water. Installation of a meter at the highest point in a pipeline must be avoided. 
The manufacturer’s Q

3

 value should not be exceed during normal operation.

The meter should be protected from stones, sand and fibrous material with a suitable strainer or filter.
The meter must be protected from pressure surges.
During operation always an upstream pressure of 0.5 bar must be ensured.
Exchanging the metrological unit

1.

2.

3.

4.

5.
5.1

5.1.1

5.1.2

5.2

5.2.1

5.2.2

5.3

5.4

5.4.1
5.4.2
5.4.3
5.4.4

5.4.5

5.4.6
5.4.7
5.4.8
5.4.9
5.4.10
5.4.11

5.4.12

5.4.13

5.4.14
5.4.15
5.4.16
5.4.17

MeiTwin / MeiTwinRF

with flow stabilizer (MID)

Installation Manual

EN DE FR ES

Reading

When reading a compound meter always both indexes (main and by-pass meter) must be read. The consumption is always 

the total of both meters. 
The black digits on the roller counter indicate full cubic metres. Parts of a cubic metre are indicated by red rollers and/or red 

sweep hands.

6.

Mechanical register display
MeiTwin

Electronic register display 

MeiTwin

LCD Segments test 

(1 sec every minute)

Testing Mode

Forward Flow

Reverse Flow

Alarm Set

Flow Direction

LC Display

Forward Flow

+ with flashing circle

Reverse Flow

- with flashing circle

No Flow

N, nor - circle

Transmission icon

Flashing mode by activated radio (1 sec on/ 1 sec off)

Low  Battery Types

Description

Low Battery

Low battery alarm will be triggered 15 

months before the calculated end of life. 

(steady display – not blinking)

Very Low Battery 

Low battery alarm will be triggered 6 months 

before the calculated end of life (flashing 

display)

The “Bell” icon is flashing when the register is in a testing mode

When an alarm is triggered the alarm icon will be visible on the LCD

7. Orientation

Cubic Meters

Litre

Imperial Gallons

US Gallons

Cubic Feet

Kilo Litre

8. Transport

Electronic register display MeiTwinRF

9. Maintenance and cleaning

Under normal conditions the meter is maintenance free. If required the measuring insert can be 

removed from the body and be cleaned. Chemicals, sharp objects or high-pressure cleaners must 

not be used for cleaning.

10. Disposal

This product contains a lithium Ion battery. In the interest of protecting the environment, this
battery may not be disposed in household waste after its period of use. The local and national
regulations for environmental protection are to be considered.

MB 1810 INT4 / 08-2017 • 0006  │  www

.sensus.com   │  info.int

@xyleminc.com

Metrological units must be replaced by metrological units with an identical metrology marking. Metrological 

units with MID approval must be installed only in bodies with the marking “MID” on the upper flange surface.
Before the installation of a replacement metrological unit the inside surface of the body, especially the sealing areas 

of the O-ring must be checked for damage. The drain screw on the bottom must be removed and the body drained. 

Thereafter the screw can be used again. A new gasket for the drain screw and O-ring for the measuring insert must 

be used (included in the delivery).
The detection of damages on the body or drain screw demands its replacement.
The body must be cleaned, debris must be removed.
The O-ring and the lip seal must be lubricated with grease approved for use with potable water before installation 

into the meter body. 
To avoid damaging the O-ring when installing a metrological unit, the O-ring must first be fitted onto the cover flange 

and then pushed into the meter body. If the O-ring is fitted into the body first, it can be pinched when fitting the meter 

insert and cause leaks.
When installing the metrological unit into the meter body, make sure that the direction of the arrow on the head flange 

aligns with the arrow on the meter body. 
The screws fixing the metrological unit in the body shall be screwed hand tight and then tightened crosswise with 

an Allen key. The recommended torque is max. 160 Nm (M16).
With meters used for billing at least one screw of the metrological unit shall be sealed against the meter body after 

the exchange to avoid tampering.



Main meter DN 50 - 100

By-Pass meter

Type

Register

Pipe

MeiTwin with By-Pass 
meter

612MTW, 612MTW-HRI 
and 612MTW-ER56

Upwards or sideways

Horizontal

Vertical

1241

Lithium