1.5.6 Pin assignments 6-wire cable
Color
Connection
Pink
IE1+
Grey
IE1
┴
Yellow
IE2+
Green
IE2
┴
Brown
IE3+
White
IE3
┴
1.6 One potential-free pulse output (optional)
The potential-free pulse output provides counting pulses of the meter.
The pulse output closes corresponding to the pulse value, see item „pulse value pulse output
1“ in display loop “6” (module loop).
From firmware version 1.03 (PolluStat) and 1.00 (PolluStat & PolluTherm F) on the meter
recognizes nominal size and unit of energy and autonomously sets the pulse values for energy and
volume according to the following notes.
PolluStat - pulse output for energy:
Display
shows
kWh / MWh
Display shows
Gcal
Display shows
GJ
Display shows
MMBTU
q
p
0,6 m
3
/h
1 kWh/pulse
1 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
q
p
1,5 m
3
/h
1 kWh/pulse
1 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
q
p
2,5 m
3
/h
1 kWh/pulse
1 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
q
p
3,5 m
3
/h
10 kWh/pulse
10 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
q
p
6 m
3
/h
10 kWh/pulse
10 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
q
p
10 m
3
/h
10 kWh/pulse
10 Mcal/pulse
10 MJ/pulse
10 MMBTU/pulse
1.6.1 Pin assignments 4-wire cable
Color
Connection
Yellow
IA1
Green
IA1
Brown / White
not reserved
1.6.2 Technical data for one pulse output and two pulse outputs
Pulse outputs class
OA (electronic switch) according to EN 1434-2:2016
Connecting cable length
1 m
Heat meter
Cooling meter
Heat/cooling meter
Possible settings
pulse output 1
heat energy
(factory setting)
or volume
cooling energy
(factory setting)
or volume
heat energy
(factory setting)
or volume