User Manual 
Power modules for heating and cooling meters 
PolluTherm / PolluStat E / PolluFlow

 

 

M H 6122 INT, page 1 

1. Use of the power supply modules 

Basically there are two different calculator housings: 

 

Calculator housing 1 (PolluTherm until 2007, PolluStat E and PolluFlow until 2010) indicated by a 
lid that can be opened sideways; it is closed by a black plastic latch 

  Calculator housing 2 (PolluTherm from 2007 on, PolluTherm from 2010 on, PolluStat E and 

PolluFlow from 2010 on) indicated by a lid that is opened from bottom to top with two locking 
latches on the two bottom corners. 

The assignment of the modules for the calculators can be taken from the table. 

1.3 Power supply modules 

Module 

name 

Function 

Order 

number 

Back-up 

battery AA 

PolluTherm 

Calculator 

PolluStat E  

Calculator 

PolluFlow  
calculator 

hous. 

1 until 

2007 

hous. 

2 from 

2007 

on 

hous. 

2 from 

2010 

on 

hous. 

1 until 

2010 

hous. 

2 from 

2010 

on 

hous. 

1 until 

2010 

hous. 

2 from 

2010 

on 

Power 
module  
230 V / 3 V 

Power 
supply with 
cable 230 V 

68503917 

 

X       

Power 
module  
230 V / 3 V 

Power 
supply with 
cable 230 V 

68504679 

 

 

** 

     

Power 
module 
230V /3,6V 

Power 
supply with 
cable 230 V 

68503876 

 

     X  X  

Power 
module 
230V /3,6V 

Power 
supply with 
cable 230 V 

68504532 

3,6 V -JST-St. 
68504900 * 

   X  X  X 

Power 
module  
24 V / 3 V 

Power 
supply with 
cable  
24 V AC 

68504529 

 

 

** 

     

Power 
module 
24 V / 3,6V 

Power 
supply with 
cable  
24 V AC 

68504533 

3,6 V -JST-St. 
68504900

 * 

   X  X  X 

* PolluStat E, PolluFlow and PolluTherm: when changing to power supply the back-up battery AA 3.6 V is 
always included in the delivery 
** Retrofitting to mains power is only possible after exchanging the integrator modules to the new version  

 

2. Safety instructions 

 

The above mentioned modules may only be used for the devices provided for in the list as otherwise 
the modules or the heat meter could be damaged  

 

Exchanging batteries with power supply units requires a careful handling of the batteries. Batteries 
must not be recharged, short-circuited, put in contact with water or exposed to temperatures of more 
than 80 °C 

  Power modules for calculator housing 1 have an internal back-up battery. The same safety 

instructions as mentioned in the previous point apply 

 

Power modules for calculator housing 2 do not have an internal back-up battery anymore; they can 
be stored indefinitely 

 

Batteries and electronic waste may only be disposed at suitable collection centers for professional 
waste disposal 

 

The connection of network modules may only be done by persons authorized and trained for that 

purpose. Furthermore the generally accepted rules of technology and VDE 0100 in particular have to 
be observed 

 

Power module must be fed from supplies fused at 6 A protection  

 

Before exchanging a power module the existing power module has to be switched off 

 

When the power module is damaged it has to be scrapped and replaced with a new one 