Description

Sensus PulseRF-A3 is a radio transponder with a fixed cable 

connection  to  a  HRI  via  a  cable  which  is  compatible  with  a 

wide range of Sensus meters. It can be retrofitted to meters 

equipped with a metal plate on the pointer without breaking 

the meter seal.

Delivery parts

Sensus PulseRF-A3 with wall adapter for the radio transponder, 

2 screws and wall plugs, adapter ring, meter lid, 2 screws, 2 

screw seals, 1 adhesive seal

Installation:

Just  before  mounting  the  HRI  on  the  meter 

it  is  essential  to  remove  the  aluminium  foil  at 

the  bottom  side.  A  screwdriver  Torx  (T8)  is 

recommended. 

Meters with plastic register 

(mounting holes in plastic head)

Change  the  lids  and  put  the  HRI  on  the  meter,  so  that  the 

two pins on top of the register fit exactly into the holes at the 

bottom of the HRI. Fit the two screws. For tamper protection fit 

the plastic seals on top of the screws. The adapter and two of 

the screws are not used for this register type.

3

 Meter with glass-copper register 

First  exchange  the  lids  (ref.  picture  2).  Fit  the  adapter  ring 

on the top of the meter register and turn it until it drops into 

place. Push and turn the adapter ring clockwise until the lever 

clicks into place. Secure the adapter ring with one of the three 

delivered screws. If required fit the adhesive seal. Mount the 

HRI with the two enclosed screws on the adapter ring. Secure 

the  screws  by  pushing  in  the  enclosed  plastic  covers.  To 

remove the HRI lift the lever and rotate anticlockwise.

Communication

The  current  SensusRF  protocol  with  the  SensusREAD  tool 

and SIRT perform this function to configure and also read the 

Sensus PulseRF.

Sensus PulseRF is also supported by the Fixed Radio Network 

Software IRIS and IRISlite.

Configuration

The  module  can  be  configured  using  SensusRF  radio  with 

SIRT and configuration software.

• 

Activation by radio or automatic by first 10 pulses

• 

Sensus  PulseRF  protocol  is  encrypted  with  a  default 

encryption key

Equipment

1. Radio transponder Sensus PulseRF      2. Wall holder

For  the  SensusRF  radio  module  choose  a  position  which 

affects  the  radio  signal  as  little  as  possible.  Metal,  soil  and 

water (e.g. power supply line or a water pipe) have a negative 

impact on the radio transmission. The effect of plastic is lower  

than concrete or wood. Try to avoid a position close to these 

materials. In pits the transponder must be mounted above the 

water line and at a minimum distance of 200 mm to metal lid 

covers. Transponders should not be closer together than 80 

cm. Test the best position before final installation.

Radio range

The  typical  distance  between  transponder  and  read-out 

device is 500m@868MHz (350m@433MHz) in line of sight. 

Poor  installation  places,  obstacles  in  the  radio  line-of-sight 

and  other  influences  like  electrical  interference  or  metal 

devices can reduce the radio range or even make radio reads 

impossible. From buildings to outside a typical range is 100 to 

200 metres, while in an extreme case the reading range in a 

pit might be less than 20 metres.

Installation of the wall holder

The  wall  plate  is  surface  mounted  using  two 

screws. Leave sufficient slack cable and space so 

that the transponder can be replaced in the future. 

Do not install the transponder upside down!

Fitting / Removing the transponder

To  fit  the  transponder  push  the  rectangular 

protrusions on the back into the mating holes in the wall plate 

and push down. To remove the transponder, do it vice versa.

Disposal instructions

This  product  contains  lithium  batteries.  To 

protect  the  environment  it  should  not  be 

disposed of in household waste when its 

serviceable life is over. Do not destroy, drill or 

demolish the module housing!

Disposal  can  take  place  through  a  Sensus 

Service Centre. If however you want to take 

care of the disposal yourself please comply 

with  the  local  and  national  regulations  for 

environmental protection.

Technical data (Radio module only)

Technical norms & applied 

standards 

see Declaration of 

Conformity

RoHS, WEEE

Frequency

868 MHz (433 MHz)

Transmitter power

25 mW (10 mW)

Power supply

Lithium batteries sealed

Battery life time

Typically 12+ years 

depending on usage profile

Cable length

2.5 m (incl. HRI)

Protection class

IP 68

Operation temperature

min -20 °C / max +60 °C

Storage temperature

-20 °C to +60 °C

Dimensions

max.: 47 x 120 x 40 mm

Weight

390 g

Radio protocol

SensusRF radio protocol

bi-directional

FlexNet protocol (TFX)

bi-directional

wM-Bus OMS unidirectional

Technical data of HRI are in the HRI datasheet

www.sensus.com