Description

Sensus PulseRF is a radio pulse transponder to be 

connected to a pulse output of a meter. It can be connected 

with C&I water meters, as well as any other meters with 

pulse output such as water, electricity, gas and thermal 

energy meters.

Equipment

1. Radio transponder Sensus PulseRF

2. Wall holder

   

 

 

 

           85 mm hole center distance

Required tools

The module can be configured using SensusRF radio with 

SIRT and a configuration software such as SensusREAD. 

It can be activated automatically after 10 pulses or via 

radio.

Pulse interface

The Sensus PulseRF has a 4 wire input enabling the 

following functions

•  Pulse input (+) (white)

•  Cable cut (green)*

•  Direction (yellow)*

•  Ground (-) (brown)

* Depending on the connected pulse device

Open inputs or unused wires should be isolated

Pulse input compatibility

Pulses should be voltage free

Min. pulse length 

32 ms (closed)

Min. pulse pause 

60 ms (open)

Max. pulse frequency 

9 Hz

Detection for closed 

(0 - 0.7) V

Detection for open 

(2.0 - 2.5) V

Max. cable capacity 

10 nF

Max. bouncing time (Reed)  2.5 ms

Internal pull up resistance  10 kOhm

Internal pull up voltage 

2.5 V

For the SensusRF radio module choose a position which 

affects the radio signal as little as possible. Metal, soil 

and water (e.g. power supply line or a water pipe) have 

a negative impact on the radio transmission. The effect 

of plastic is lower than concrete or wood. Try to avoid a 

position close to these materials. In pits the transponder 

must be mounted above the water line and at a minimum 

distance of  200 mm to metal lid covers. Transponders 

should not be closer together than 80 cm. Test the best 

position before the final installation.

Radio range

The typical distance between transponder and read-out 

device is 500m@868MHz (350m@433MHz) in line of 

sight. Poor installation places, obstacles in the radio line-

of-sight and other influences like electrical interference or 

metal devices can reduce the radio range or even make 

radio reads impossible. From buildings to outside a typical 

range is 100 to 200 metres, while in an extreme case the 

reading range in a pit might be less than 20 metres.

Installation of the wall holder

The wall plate is surface mounted using two 

screws. Leave sufficient slack cable and space so 

that the transponder can be replaced in the future.  

Do not install the transponder upside down! 

Fitting / Removing the transponder

To fit the transponder push the rectangular protrusions on 

the back into the mating holes in the wall plate and push 

down. To remove the transponder, do it vice versa.

Disposal instructions

This product contains lithium batteries. To 

protect the environment it should not be 

disposed of in household waste when its 

serviceable  life  is  over.  Don’t  destroy  or 

drill or demolish the module housing!

Disposal  can  take  place  through  a 

Sensus Service Centre. If however you 

want to take care of the disposal yourself, 

please comply with the local and national 

regulations for environmental protection.

Technical data

Technical norms & 

applied standards

see Declaration of Conformity

RoHS, WEEE

Frequency

868 MHz (433 MHz)

Transmitter power

25 mW (10mW)

Power supply

Lithium batteries sealed

Battery life time

Typically 15+ years depending on 

usage profile

Cable length

2.5 m (max. extension to 15 m)

Protection class

IP 68

Operation 

temperature

min -20 °C / max +60 °C

Storage 

temperature

-20 °C to + 60 °C

Dimensions

max.: 47 x 120 x 40 mm

Weight

260 g

Radio protocol

SensusRF radio protocol

bi-directional

FlexNet protocol (TFX)

bi-directional

wMBus OMS unidirectional

Installation manual

Sensus PulseRF

MS 2800 INT6 / 07-2017• 0002

EN DE FR ES

Sensus PulseRF - HRI-A3/HRI-B3

PulseRF

HRI-A3/B3

Settings:

Direction ON

Cable Cut OFF

Cable cut

Direction

Pulses (+)

Ground (-)

(yellow)

(brown)

(white)

(yellow)

Pulses (+)

(white)

Ground (-)

(brown)

(green)

Sensus PulseRF - HRI-Mei B3

PulseRF

HRI-Mei B3

Settings:

Direction ON

Cable Cut OFF

Cable cut

(green)

Sensus PulseRF - Reed RD

PulseRF

Reed RD

Settings:

Direction OFF

Cable Cut OFF

Sensus PulseRF - open collector

Connection diagram & configuration

PulseRF

Settings:

Cable cut (optional)

Direction (optional)

Open = forward

Close = backwards

Direction

Direction

(yellow)

(yellow)

Direction

Pulses (+)

(white)

Pulses (+)

(white)

Ground (-)

(brown)

Ground (-)

(grey)

Cable cut

(green)

Direction

(yellow)

Pulses (+)

(white)

Pulses (+)

(black)

Ground (-)

(brown)

Ground (-)

(brown)

Cable cut

(green)

Direction

(yellow)

Pulses (+)

(white)

Ground (-)

(brown)

SV

FI

Reviews: