7.2 Initial Start-Up
7.2.1 Safety Instructions
WARNING!
Gas containing ozone in system components and pipes!
Even during the initial start-up ozone is generated. Hazard of toxic effects
and breathing difficulties.
If you smell ozone:
Immediately set the power switch to
0
.
Leave the operating room while observing the safety measures.
After thorough ventilation of the operating room search for the
leakage. Maybe not all the connections are sufficiently tightened.
Although the system was factory tested, connections might have
loosened during transport.
The initial start-up always takes place in manual mode.
Make sure that the system has been given enough time to adapt
to the climatic conditions of the location before it is activated for
the first time.
7.2.2 Requirements for the Commissioning Staff
The ozone system may be commissioned by qualified persons
(
refer to section Classification of
Operating Staff
)
only.
7.2.3 Starting the Ozone System Initially
The following steps must be carried out before initial commissioning:
1. Check that all supply media for the system are available according to the technical data
(gas, cooling water, power).
2. Check that the subsequent process technology for the ozone generated is ready to
accept it and can process it according to its purpose.
3. Check that all safety equipment is available and enabled.
4. Set all manual valves to operating position.
5. Let the cooling water flow into the system and bleed the pipe work.
6. Set the cooling water flow according to the instructions given in
section Technical Data
.