10.3 Temporary
System Shutdown
If the ozone system is temporarily to be shut down or if the system is to be employed at
another place, proceed as follows:
1. Purge the ozone system with dry oxygen or nitrogen until the lines are free of ozone
and an atmospheric dew point of -70°C has been reached.
2. Set the main switch to
0/Off
. Depressurize all the piping and system components.
3. Close the feed gas inlets.
4. Seal the gas lines.
5. Discharge the cooling water.
6. Disconnect the system from the media supply connections. Make sure that no leakages
occur when disconnecting the connections.
7. Disconnect all electrical connections from the system. Ensure that loosened cable
connections remain with the ozone system.
8. Make sure that there is no way to activate any switches or to confuse any connections.
9. Protect lines and connections from damage during transport and storage.
10. Loosen all fixings located on the wall and floor.
11. Separate the components.
12. Ensure the ozone system is protected from frost.